Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1413/13  Evaporator Temperature Sensor Circuit  


DESCRIPTION

The No. 1 cooler thermistor is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.

DTC Code DTC Detection Condition Trouble Area
B1413/13 An open or short in the No. 1 cooler thermistor circuit.
·

No. 1 cooler thermistor

·

Air conditioning harness assembly (No. 1 cooler thermistor)

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E140288E08
4.832,2.001 5.154,2.154 0.321,0.153 10 z53 4.832,2.167 7.077,2.370 2.244,0.203 10 Air Conditioning Amplifier Assembly 4.892,0.672 5.209,0.817 0.318,0.146 10 TEA 4.892,1.549 5.256,1.691 0.364,0.142 10 SGA 4.599,0.56 4.743,0.775 0.144,0.214 10 7 2.386,0.546 2.530,0.761 0.144,0.214 10 1 4.599,1.423 4.743,1.638 0.144,0.214 10 6 2.386,1.423 2.530,1.638 0.144,0.214 10 2 2.206,0.598 2.350,0.812 0.144,0.214 10 + 2.206,1.475 2.350,1.689 0.144,0.214 10 - 0.622,2.004 2.208,2.186 1.586,0.181 10 No. 1 Cooler Thermistor 0.048,0.031 2.425,0.213 2.378,0.181 12 w/ Rear Heater: 2.773,2.02 4.348,2.370 1.575,0.351 10 Air Conditioning Harness Assembly

E140288E52
4.635,2.021 4.958,2.177 0.323,0.156 10 false z54 4.635,2.198 7.052,2.49 2.417,0.292 10 false Air Conditioning Amplifier Assembly 4.865,0.719 5.271,0.927 0.406,0.208 10 false TEA 4.875,1.583 5.24,1.792 0.365,0.208 10 false SGA 4.615,0.615 4.76,0.833 0.146,0.219 10 false 6 2.385,0.604 2.531,0.823 0.146,0.219 10 false 1 2.406,1.469 2.552,1.688 0.146,0.219 10 false 2 2.208,0.604 2.354,0.823 0.146,0.219 10 false + 2.219,1.469 2.365,1.688 0.146,0.219 10 false - 4.615,1.469 4.76,1.688 0.146,0.219 10 false 5 0.677,2.042 2.281,2.219 1.604,0.177 10 false No. 1 Cooler Thermistor 0.083,0 1.688,0.177 1.604,0.177 12 false w/o Rear Heater: 2.813,2.021 4.063,2.406 1.25,0.385 10 false Air Conditioning Harness Assembly

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (NO. 1 COOLER THERMISTOR)
a.

Use the Data List to check if the No. 1 cooler thermistor is functioning properly.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Evaporator Fin Thermistor No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).

OK:

The display is as specified in the normal condition.




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT NO. 1 COOLER THERMISTOR
2.INSPECT NO. 1 COOLER THERMISTOR
E345466E02
0.49,1.958 0.688,1.615 0.688,1.615 0.938,1.615 false 2.552,1.792 2.74,1.26 false 2.448,1.781 2.271,1.271 false 4.042,0.479 5.063,0.656 1.021,0.177 10 false Resistance (kΩ) 3.885,0.792 4.177,0.969 0.292,0.177 10 false 10.0 0.979,1.531 1.49,1.698 0.51,0.167 10 false Sensor 3.948,2.594 4.188,2.771 0.24,0.177 10 false 0.0 3.938,2.396 4.177,2.573 0.24,0.177 10 false 1.0 3.938,2.208 4.177,2.385 0.24,0.177 10 false 2.0 3.938,2.042 4.177,2.219 0.24,0.177 10 false 3.0 3.938,1.865 4.177,2.042 0.24,0.177 10 false 4.0 3.938,1.698 4.177,1.875 0.24,0.177 10 false 5.0 3.938,1.521 4.177,1.698 0.24,0.177 10 false 6.0 3.927,1.344 4.167,1.521 0.24,0.177 10 false 7.0 3.938,1.177 4.177,1.354 0.24,0.177 10 false 8.0 3.938,0.979 4.177,1.156 0.24,0.177 10 false 9.0 4.771,2.708 5.01,2.885 0.24,0.177 10 false 0 5.323,2.719 5.563,2.896 0.24,0.177 10 false 10 5.896,2.708 6.135,2.885 0.24,0.177 10 false 20 6.5,2.708 6.74,2.885 0.24,0.177 10 false 30 4.208,2.708 4.448,2.885 0.24,0.177 10 false -10 4.208,2.885 4.469,3.094 0.26,0.208 10 false (14) 4.719,2.896 4.979,3.104 0.26,0.208 10 false (32) 5.313,2.896 5.573,3.104 0.26,0.208 10 false (50) 5.875,2.885 6.135,3.094 0.26,0.208 10 false (68) 6.469,2.885 6.729,3.094 0.26,0.208 10 false (86) 5.198,3.25 5.99,3.417 0.792,0.167 10 false Temperature 6.031,3.25 6.292,3.615 0.26,0.365 10 false °C (°F) 2.177,1.01 2.365,1.188 0.188,0.177 10 false - 2.74,1.031 2.927,1.208 0.188,0.177 10 false +


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (+) - 2 (-) -10°C (14°F) 7.30 to 9.10 kΩ
-5°C (23°F) 5.65 to 6.95 kΩ
0°C (32°F) 4.40 to 5.35 kΩ
5°C (41°F) 3.40 to 4.15 kΩ
10°C (50°F) 2.70 to 3.25 kΩ
15°C (59°F) 2.14 to 2.58 kΩ
20°C (68°F) 1.71 to 2.05 kΩ
25°C (77°F) 1.38 to 1.64 kΩ
30°C (86°F) 1.11 to 1.32 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


Result
Result Proceed to
OK (for LHD) A
OK (for RHD) B
NG (for LHD) C
NG (for RHD) D



A

B

C

D