The No. 1 cooler thermistor is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413/13 | An open or short in the No. 1 cooler thermistor circuit. | ·
No. 1 cooler thermistor ·
Air conditioning harness assembly (No. 1 cooler thermistor) ·
Air conditioning amplifier assembly |
Use the Data List to check if the No. 1 cooler thermistor is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F). |
The display is as specified in the normal condition.
OK
NG
Remove the No. 1 cooler thermistor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (+) - 2 (-) | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for LHD)>DISASSEMBLY)
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for RHD)>DISASSEMBLY)
C
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR(for LHD)>DISASSEMBLY)
D
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR(for RHD)>DISASSEMBLY)