Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › from 2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1441/41  Air Mix Damper Control Servo Motor Circuit (Passenger Side)  


DESCRIPTION

*1: for LHD

*2: for RHD


The air mix damper servo motor RH*1 or LH*2 sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the air mix damper servo motor RH*1 or LH*2 to any position. As a result, the amount of air that has passed through the evaporator and is passing through the heater core is adjusted, and the temperature of the air blowing toward the front passenger side is controlled.

HINT:

Confirm that no mechanical problem is present because this trouble code can be output when either a damper link or damper is mechanically locked.


DTC Code DTC Detection Condition Trouble Area
B1441/41 The air mix damper position does not change even if the air conditioning amplifier assembly operates the air mix damper servo motor.
·

Air mix damper servo motor RH*1

·

Air mix damper servo motor LH*2

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly



WIRING DIAGRAM

w/ Rear Heater:


E330394E57
4.833,0.479 5.292,0.677 0.458,0.198 10 false BUS 4.833,0.771 5.292,0.969 0.458,0.198 10 false B BUS 4.844,1.094 5.302,1.292 0.458,0.198 10 false BUS G 4.625,0.427 5.083,0.625 0.458,0.198 10 false 2 4.625,0.781 5.083,0.979 0.458,0.198 10 false 3 4.635,1.094 5.094,1.292 0.458,0.198 10 false 1 4.979,1.823 5.333,2.021 0.354,0.198 10 false z72 4.969,2.01 6.573,2.396 1.604,0.385 10 false Air Conditioning Amplifier Assembly 3.135,1.729 4.667,2.094 1.531,0.365 10 false Air Conditioning Harness Assembly 0.438,1.708 2.948,1.906 2.51,0.198 10 false Air Mix Damper Servo Motor RH*1, LH*2 0.74,2.417 2.417,2.625 1.677,0.208 10 false : LIN Communication Line 2.521,2.427 3.313,2.625 0.792,0.198 10 false *1: for LHD 3.365,2.417 4.156,2.615 0.792,0.198 10 false *2: for RHD


w/o Rear Heater:


E330394E58
4.833,0.479 5.292,0.677 0.458,0.198 10 false BUS 4.833,0.771 5.292,0.969 0.458,0.198 10 false B BUS 4.844,1.094 5.302,1.292 0.458,0.198 10 false BUS G 5.844,0.594 6.302,0.792 0.458,0.198 10 false IC 6.438,0.781 6.896,0.979 0.458,0.198 10 false +B 4.625,0.427 5.083,0.625 0.458,0.198 10 false 3 4.625,0.781 5.083,0.979 0.458,0.198 10 false 4 4.635,1.094 5.094,1.292 0.458,0.198 10 false 2 4.979,1.823 5.438,2.021 0.458,0.198 10 false z71 4.969,2 6.563,2.385 1.594,0.385 10 false Air Conditioning Amplifier Assembly 3.104,1.719 4.625,2.083 1.521,0.365 10 false Air Conditioning Harness Assembly 0.427,1.708 2.906,1.948 2.479,0.24 10 false Air Mix Damper Servo Motor RH*1, LH*2 0.729,2.406 2.448,2.615 1.719,0.208 10 false : LIN Communication Line 2.573,2.396 3.396,2.604 0.823,0.208 10 false *1: for LHD 3.531,2.396 4.354,2.604 0.823,0.208 10 false *2: for RHD


PROCEDURE

1.READ VALUE USING GTS (AIR MIX SERVO TARG PULSE[P], AIR MIX SERVOACTUAL PULSE[P])

*1: for LHD

*2: for RHD


a.

Use the Data List to check if the air mix damper servo motor RH*1 or LH*2 is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Air Mix Servo Targ Pulse (P) Air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.: 383
for LHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


for RHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


·

Displayed between 249 and 331 pulse (for LHD)

·

Displayed between 181 and 263 pulse (for RHD)

·

Air mix damper servo motor LH*1 or RH*2 system malfunction


Air Mix Servo Actual Pulse(P) Air mix damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.: 383
for LHD:
·

MAX COLD: 331 (pulse)

·

MAX HOT: 249 (pulse)


for RHD:
·

MAX COLD: 181 (pulse)

·

MAX HOT: 263 (pulse)


·

Displayed between 249 and 331 pulse (for LHD)

·

Displayed between 181 and 263 pulse (for RHD)

·

Air mix damper servo motor LH*1 or RH*2 system malfunction



OK:

When the front passenger side temperature adjustment switch is turned from MAX COLD to MAX HOT, the actual pulse changes following the target pulse.


Result
Result Proceed to
Target pulse changes but actual pulse does not change) A
Target pulse and actual pulse do not change B
Actual pulse changes following the target pulse (When troubleshooting according to the DTC) C
Actual pulse changes following the target pulse (When troubleshooting according to Problem Symptoms Table) E



A

2.CHECK AIR MIX DAMPER SERVO MOTOR (for Front Passenger Side)

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

C

4.CHECK FOR DTC

D

2.CHECK AIR MIX DAMPER SERVO MOTOR (for Front Passenger Side)
a.

for LHD:



b.

for RHD:



HINT:

Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one.





A

END (AIR MIX DAMPER SERVO MOTOR [for Front Passenger Side] WAS DEFECTIVE)

B

3.CHECK AIR CONDITIONING HARNESS ASSEMBLY
3.CHECK AIR CONDITIONING HARNESS ASSEMBLY

A

END (AIR CONDITIONING HARNESS ASSEMBLY WAS DEFECTIVE)

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY