*1: for LHD
*2: for RHD
The air mix damper servo motor RH*1 or LH*2 sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the air mix damper servo motor RH*1 or LH*2 to any position. As a result, the amount of air that has passed through the evaporator and is passing through the heater core is adjusted, and the temperature of the air blowing toward the front passenger side is controlled.
Confirm that no mechanical problem is present because this trouble code can be output when either a damper link or damper is mechanically locked.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1441/41 | The air mix damper position does not change even if the air conditioning amplifier assembly operates the air mix damper servo motor. | ·
Air mix damper servo motor RH*1 ·
Air mix damper servo motor LH*2 ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
w/ Rear Heater:
w/o Rear Heater:
*1: for LHD
*2: for RHD
Use the Data List to check if the air mix damper servo motor RH*1 or LH*2 is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse (P) | Air mix damper servo motor RH*1 or LH*2 target pulse / Min.: 128, Max.: 383 | for LHD:
·
MAX COLD: 331 (pulse) ·
MAX HOT: 249 (pulse) for RHD:
·
MAX COLD: 181 (pulse) ·
MAX HOT: 263 (pulse) |
·
Displayed between 249 and 331 pulse (for LHD) ·
Displayed between 181 and 263 pulse (for RHD) ·
Air mix damper servo motor LH*1 or RH*2 system malfunction |
| Air Mix Servo Actual Pulse(P) | Air mix damper servo motor RH*1 or LH*2 actual pulse / Min.: 128, Max.: 383 | for LHD:
·
MAX COLD: 331 (pulse) ·
MAX HOT: 249 (pulse) for RHD:
·
MAX COLD: 181 (pulse) ·
MAX HOT: 263 (pulse) |
·
Displayed between 249 and 331 pulse (for LHD) ·
Displayed between 181 and 263 pulse (for RHD) ·
Air mix damper servo motor LH*1 or RH*2 system malfunction |
When the front passenger side temperature adjustment switch is turned from MAX COLD to MAX HOT, the actual pulse changes following the target pulse.
| Result | Proceed to |
|---|---|
| Target pulse changes but actual pulse does not change) | A |
| Target pulse and actual pulse do not change | B |
| Actual pulse changes following the target pulse (When troubleshooting according to the DTC) | C |
| Actual pulse changes following the target pulse (When troubleshooting according to Problem Symptoms Table) | E |
A
B
C
D
for LHD:
Replace the air mix damper servo motor RH (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for LHD)>DISASSEMBLY).
for RHD:
Replace the air mix damper servo motor LH (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for RHD)>DISASSEMBLY).
Since the servo motor cannot be inspected while it is removed from the vehicle, replace the servo motor with a normal one.
Check for DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
DTC B1441/41 is not output.
A
B
Replace the air conditioning harness assembly with a new or known good one.
Check for DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
DTC B1441/41 is not output.
A
B
Check for DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
DTC B1441/41 is not output.
OK
(See pageGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING)
NG