The rear blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. The rear blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
The rear blower motor controller controls the rear blower with fan motor sub-assembly speed.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Select the Active Test, use the GTS to generate a control command, and then check that the rear blower with fan motor sub-assembly operates (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Blower Motor | Rear blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
Rear blower with fan motor sub-assembly is operated normally using the GTS.
OK
NG
Remove the rear blower with fan motor sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>REMOVAL).
Inspect the rear blower with fan motor sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>INSPECTION).
OK
NG
Disconnect the wiring air conditioning harness sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to Wiring Air Conditioning Harness Sub-assembly) |
OK
NG
Disconnect the wiring air conditioning harness sub-assembly connector.
Disconnect the E36 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 8 - E36-17 (BLWH) | Always | Below 1 Ω |
| 8 or E36-17 (BLWH) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the wiring air conditioning harness sub-assembly with a new or known good one and check that the condition returns to normal.
Same problem does not occur.
OK
NG
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | z51-3 (SI) - Body ground |
| Tool Setting | 2 V/DIV., 500 μs/DIV. |
| Condition | ·
Ignition switch ON ·
Blower switch LO |
Waveform is as shown in the illustration.
Waveform varies with the blower level.
OK
NG
Replace the blower motor control with a new or known good one and check that the condition returns to normal.
Same problem does not occur.
OK
NG