The blower with fan motor sub-assembly operates according to signals from the air conditioning amplifier assembly. The blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
Duty Ratio:
The duty ratio is the ratio of the blower with fan motor sub-assembly on time (T1) to the total of the blower with fan motor sub-assembly on and off time (T2).
The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Select the Active Test, use the intelligent tester to generate a control command, and then check that the blower with fan motor sub-assembly operates (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
Blower with fan motor sub-assembly operates and blower with fan motor sub-assembly speed changes.
OK
NG
Disconnect the A29 blower with fan motor sub-assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-3 (+B) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-1 (GND) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Blower with Fan Motor Sub-assembly) |
OK
NG
Disconnect the E81 air conditioning amplifier assembly connector.
Disconnect the A29 blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E81-23 (BLW) - A29-2 (SI) | Always | Below 1 Ω |
| E81-23 (BLW) - Body ground | Always | 10 kΩ or higher |
| E81-14 (GND) - Body ground | Always | Below 1 Ω |
OK
NG
Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | E81-23 (BLW) - E81-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | Ignition switch ON
Blower switch LO level |
Waveform is as shown in the illustration.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Waveform varies with the blower level.
OK
NG
Temporarily replace the blower with fan motor sub-assembly with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>REMOVAL).
NEXT
Operate the blower with fan motor sub-assembly to check that it functions properly.
Blower with fan motor sub-assembly operates normally.
OK
NG