Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) › from 2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255703 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  PTC Heater Circuit  


DESCRIPTION

The air conditioning amplifier assembly sends operation signals to the PTC heater relays when quick heater assembly operation conditions are met. Based on the signals from the air conditioning amplifier assembly, the PTC heater relays turn on, and power is supplied to the quick heater assembly installed in the air conditioning radiator assembly.

Control ECU Condition
Air Conditioning Amplifier Assembly Start the engine
Combination switch assembly (ECO mode switch) off
Blower switch: LO or more
Temperature settings: MAX HOT
·

Engine coolant temperature 65°C (149°F), or lower (3 PTC heater relays operating)

·

Engine coolant temperature 70°C (158°F), or lower (2 PTC heater relays operating)

·

Engine coolant temperature 75°C (167°F), or lower (A PTC heater relay operating)


Ambient temperature 10°C (50°F) or lower

WIRING DIAGRAM

E337639E04
5.604,1.219 6.031,1.417 0.427,0.198 10 false PTC2 5.594,2.479 6.021,2.677 0.427,0.198 10 false PTC1 5.594,3.792 6.021,3.99 0.427,0.198 10 false PTC3 5.354,1.229 5.781,1.427 0.427,0.198 10 false 3 4.25,1.208 4.677,1.406 0.427,0.198 10 false 1 3.083,1.229 3.51,1.427 0.427,0.198 10 false 2 4.25,1.615 4.677,1.813 0.427,0.198 10 false 3 3.229,2.042 4.25,2.24 1.021,0.198 10 false PTC HTR NO.2 1.906,0.635 3.052,0.833 1.146,0.198 10 false from Battery 1.927,0.125 3.073,0.323 1.146,0.198 10 false from IG1 Relay 0.792,0.281 1.771,0.479 0.979,0.198 10 false ECU-IG NO.1 3.313,5.969 3.635,6.167 0.323,0.198 10 false E33 3.323,5.771 3.646,5.969 0.323,0.198 10 false 1*1 3.313,5.573 3.635,5.771 0.323,0.198 10 false E33 3.323,5.375 3.646,5.573 0.323,0.198 10 false 2*1 3.313,5.167 3.635,5.365 0.323,0.198 10 false E33 3.073,5.063 3.25,5.26 0.177,0.198 10 false B 3.073,5.469 3.25,5.667 0.177,0.198 10 false B 3.073,5.854 3.25,6.052 0.177,0.198 10 false B 2.344,5.063 2.667,5.26 0.323,0.198 10 false E 2.344,5.854 2.667,6.052 0.323,0.198 10 false E 3.323,4.969 3.646,5.167 0.323,0.198 10 false 3*1 3.708,5.969 4.031,6.167 0.323,0.198 10 false E33 3.719,5.771 4.042,5.969 0.323,0.198 10 false 2*2 3.708,5.573 4.031,5.771 0.323,0.198 10 false E33 3.719,5.375 4.042,5.573 0.323,0.198 10 false 3*2 3.708,5.167 4.031,5.365 0.323,0.198 10 false E33 3.719,4.969 4.042,5.167 0.323,0.198 10 false 1*2 1.958,5.979 2.281,6.177 0.323,0.198 10 false E34 2.052,6.281 3.719,6.479 1.667,0.198 10 false Quick Heater Assembly 5.385,4.677 5.781,4.906 0.396,0.229 10 false E81 5.375,4.844 7.042,5.198 1.667,0.354 10 false Air Conditinoing Amplifier Assembly 1.958,5.75 2.281,5.948 0.323,0.198 10 false 1*1 1.958,5.167 2.281,5.365 0.323,0.198 10 false E34 1.958,4.948 2.281,5.146 0.323,0.198 10 false 2*1 1.531,5.969 1.875,6.167 0.344,0.198 10 false E110 1.552,5.75 1.875,5.948 0.323,0.198 10 false 1*2 0.115,6.125 1.094,6.323 0.979,0.198 10 false *1: for 600 W 0.115,6.417 1.094,6.615 0.979,0.198 10 false *2: for 840 W 1.573,5.167 1.938,5.365 0.365,0.198 10 false E34 1.604,4.948 1.927,5.146 0.323,0.198 10 false 1*2 3.094,1.625 3.521,1.823 0.427,0.198 10 false 5 4.24,2.51 4.667,2.708 0.427,0.198 10 false 1 3.094,2.51 3.521,2.708 0.427,0.198 10 false 2 4.229,2.896 4.656,3.094 0.427,0.198 10 false 3 3.219,3.313 4.24,3.51 1.021,0.198 10 false PTC HTR NO.1 3.083,2.896 3.51,3.094 0.427,0.198 10 false 5 4.25,3.781 4.677,3.979 0.427,0.198 10 false 1 3.073,3.792 3.5,3.99 0.427,0.198 10 false 2 4.24,4.177 4.667,4.375 0.427,0.198 10 false 3 3.219,4.604 4.24,4.802 1.021,0.198 10 false PTC HTR NO.3 2.052,1.885 3.073,2.083 1.021,0.198 10 false PTC HTR NO.2 2.063,3.167 3.083,3.365 1.021,0.198 10 false PTC HTR NO.1 2.073,4.448 3.094,4.646 1.021,0.198 10 false PTC HTR NO.3 3.073,4.198 3.5,4.396 0.427,0.198 10 false 5 5.313,2.5 5.74,2.698 0.427,0.198 10 false 40 5.313,3.792 5.74,3.99 0.427,0.198 10 false 36

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.INSPECT PTC HEATER RELAY (PTC HTR1, PTC HTR2, PTC HTR3)
a.

Remove the PTC heater relay from the No. 1 engine room relay block.




OK

2.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - BATTERY)

NG

REPLACE PTC HEATER RELAY

2.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - BATTERY)
a.

Remove the PTC heater relays from the No. 1 engine room relay block.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
PTC HTR NO.1:
Tester Connection Condition Specified Condition
Relay block PTC HTR1 relay terminal 2 - Body ground Engine switch off Below 1 V
Relay block PTC HTR1 relay terminal 2 - Body ground Engine switch on (IG) 11 to 14 V
Relay block PTC HTR1 relay terminal 5 - Body ground Always 11 to 14 V

PTC HTR NO.2:
Tester Connection Condition Specified Condition
Relay block PTC HTR2 relay terminal 2 - Body ground Engine switch off Below 1 V
Relay block PTC HTR2 relay terminal 2 - Body ground Engine switch on (IG) 11 to 14 V
Relay block PTC HTR2 relay terminal 5 - Body ground Always 11 to 14 V

PTC HTR NO.3:
Tester Connection Condition Specified Condition
Relay block PTC HTR3 relay terminal 2 - Body ground Engine switch off Below 1 V
Relay block PTC HTR3 relay terminal 2 - Body ground Engine switch on (IG) 11 to 14 V
Relay block PTC HTR3 relay terminal 5 - Body ground Always 11 to 14 V




OK

3.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Remove the PTC heater relays from the No. 1 engine room relay block.


b.

Disconnect the E81 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
PTC HTR NO.1:
Tester Connection Condition Specified Condition
Relay block PTC HTR1 relay terminal 1 - E81-40 (PTC1) Always Below 1 Ω
Relay block PTC HTR1 relay terminal 1 or E81-40 (PTC1) - Body ground Always 10 kΩ or higher

PTC HTR NO.2:
Tester Connection Condition Specified Condition
Relay block PTC HTR2 relay terminal 1 - E81-3 (PTC2) Always Below 1 Ω
Relay block PTC HTR2 relay terminal 1 or E81-3 (PTC2) - Body ground Always 10 kΩ or higher

PTC HTR NO.3:
Tester Connection Condition Specified Condition
Relay block PTC HTR3 relay terminal 1 - E81-36 (PTC3) Always Below 1 Ω
Relay block PTC HTR3 relay terminal 1 or E81-36 (PTC3) - Body ground Always 10 kΩ or higher




OK

4.CHECK HARNESS AND CONNECTOR (QUICK HEATER ASSEMBLY - PTC HEATER RELAY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (QUICK HEATER ASSEMBLY - PTC HEATER RELAY AND BODY GROUND)
a.

for 600 W

i.

Remove the PTC heater relays from the No. 1 engine room relay block.


ii.

Disconnect the E33 and E34 quick heater assembly connectors.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
PTC HTR NO.1:
Tester Connection Condition Specified Condition
E33-3 (B) - Relay block PTC HTR1 relay terminal 3 Always Below 1 Ω
E34-1 (E) - Body ground Always Below 1 Ω
E34-2 (E) - Body ground Always Below 1 Ω
E33-3 (B) or Relay block PTC HTR1 relay terminal 3 - Body ground Always 10 kΩ or higher

PTC HTR NO.2:
Tester Connection Condition Specified Condition
E33-2 (B) - Relay block PTC HTR2 relay terminal 3 Always Below 1 Ω
E34-1 (E) - Body ground Always Below 1 Ω
E33-2 (B) or Relay block PTC HTR2 relay terminal 3 - Body ground Always 10 kΩ or higher

PTC HTR NO.3:
Tester Connection Condition Specified Condition
E33-1(B) - Relay block PTC HTR3 relay terminal 3 Always Below 1 Ω
E34-2 (E) - Body ground Always Below 1 Ω
E33-1 (B) or Relay block PTC HTR3 relay terminal 3 - Body ground Always 10 kΩ or higher




b.

for 840 W

i.

Remove the PTC heater relays from the No. 1 engine room relay block.


ii.

Disconnect the E33, E34 and E110 quick heater assembly connectors.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
PTC HTR NO.1:
Tester Connection Condition Specified Condition
E33-2 (B) - Relay block PTC HTR1 relay terminal 3 Always Below 1 Ω
E110-1 (E) - Body ground Always Below 1 Ω
E34-1 (E) - Body ground Always Below 1 Ω
E33-2 (B) or Relay block PTC HTR1 relay terminal 3 - Body ground Always 10 kΩ or higher

PTC HTR NO.2:
Tester Connection Condition Specified Condition
E33-1 (B) - Relay block PTC HTR2 relay terminal 3 Always Below 1 Ω
E110-1 (E) - Body ground Always Below 1 Ω
E33-1 (B) or Relay block PTC HTR2 relay terminal 3 - Body ground Always 10 kΩ or higher

PTC HTR NO.3:
Tester Connection Condition Specified Condition
E33-3 (B) - Relay block PTC HTR3 relay terminal 3 Always Below 1 Ω
E34-1 (E) - Body ground Always Below 1 Ω
E33-3 (B) or Relay block PTC HTR3 relay terminal 3 - Body ground Always 10 kΩ or higher





OK

5.INSPECT QUICK HEATER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT QUICK HEATER ASSEMBLY
a.

b.


OK

NG