| All functions of the air conditioning system do not operate
|
Proceed to "IG Power Source Circuit"
|
( )
|
| Proceed to "Air Conditioning Control Panel Circuit"
|
( )
|
| Air Flow Control: No blower operation
|
Proceed to "Blower Motor Circuit"
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Air Flow Control: No blower control
|
Proceed to "Blower Motor Circuit"
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Air Flow Control: Insufficient air flow
|
Proceed to "Blower Motor Circuit"
|
( )
|
| Temperature Control: No cool air comes out
|
Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Proceed to "CAN Communication System (for RHD)"
|
( )
|
| Check volume of refrigerant
|
( )
|
| Check for refrigerant gas leak
|
( )
|
| Proceed to "Pressure Sensor Circuit"
|
( )
|
| Proceed to "Compressor Lock Sensor Circuit"
|
( )
|
| Proceed to "Air Mix Damper Control Servo Motor Circuit (Driver Side)"
|
( )
|
| Proceed to "Cool Air Bypass Damper Control"
|
( )
|
| Proceed to "Ambient Temperature Sensor Circuit"
|
( )
|
| Proceed to "Evaporator Temperature Sensor Circuit"
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for RHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for RHD)
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Cooler expansion valve (for LHD)
|
( )
|
| Cooler expansion valve (for RHD)
|
( )
|
| ECM (for 1VD-FTV)
|
( )
|
| ECM (for 1GR-FE)
|
( )
|
| Temperature Control: No warm air comes out
|
Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Proceed to "CAN Communication System (for RHD)"
|
( )
|
| Proceed to "Air Mix Damper Control Servo Motor Circuit (Driver Side)"
|
( )
|
| Proceed to "Cool Air Bypass Damper Control"
|
( )
|
| Proceed to "Ambient Temperature Sensor Circuit"
|
( )
|
| Proceed to "PTC Heater Circuit" (w/ PTC Heater)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for RHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for RHD)
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Heater radiator unit sub-assembly (for LHD)
|
( )
|
| Heater radiator unit sub-assembly (for RHD)
|
( )
|
| ECM (for 1VD-FTV)
|
( )
|
| ECM (for 1GR-FE)
|
( )
|
| Temperature Control: Output air is warmer or cooler than set temperature or response is slow
|
Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Proceed to "CAN Communication System (for RHD)"
|
( )
|
| Check volume of refrigerant
|
( )
|
| Check for refrigerant gas leak
|
( )
|
| Proceed to "Pressure Sensor Circuit"
|
( )
|
| Proceed to "Compressor Lock Sensor Circuit"
|
( )
|
| Proceed to "Air Mix Damper Control Servo Motor Circuit (Driver Side)"
|
( )
|
| Proceed to "Cool Air Bypass Damper Control"
|
( )
|
| Proceed to "Air Inlet Damper Control Servo Motor Circuit"
|
( )
|
| Proceed to "Ambient Temperature Sensor Circuit"
|
( )
|
| Proceed to "Evaporator Temperature Sensor Circuit"
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for RHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for RHD)
|
( )
|
| No. 1 blower damper servo sub-assembly
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Cooler expansion valve (for LHD)
|
( )
|
| Cooler expansion valve (for RHD)
|
( )
|
| Heater radiator unit sub-assembly (for LHD)
|
( )
|
| Heater radiator unit sub-assembly (for RHD)
|
( )
|
| ECM (for 1VD-FTV)
|
( )
|
| ECM (for 1GR-FE)
|
( )
|
| Temperature Control: No temperature control (only MAX. COOL or MAX. HOT)
|
Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Proceed to "CAN Communication System (for RHD)"
|
( )
|
| Proceed to "Air Mix Damper Control Servo Motor Circuit (Driver Side)"
|
( )
|
| Proceed to "Cool Air Bypass Damper Control"
|
( )
|
| Proceed to "Ambient Temperature Sensor Circuit"
|
( )
|
| Proceed to "Evaporator Temperature Sensor Circuit"
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (air mix damper servo) (for RHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for LHD)
|
( )
|
| No. 1 air conditioning radiator damper servo sub-assembly (cooler bypass damper servo) (for RHD)
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| ECM (for 1VD-FTV)
|
( )
|
| ECM (for 1GR-FE)
|
( )
|
| No air inlet control
|
Proceed to "Air Inlet Damper Control Servo Motor Circuit"
|
( )
|
| No. 1 blower damper servo sub-assembly
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| No air flow mode control
|
Proceed to "Air Outlet Damper Control Servo Motor Circuit"
|
( )
|
| No. 1 blower damper servo sub-assembly (for LHD)
|
( )
|
| No. 1 blower damper servo sub-assembly (for RHD)
|
( )
|
| Air conditioning harness assembly (for LHD)
|
( )
|
| Air conditioning harness assembly (for RHD)
|
( )
|
| Air conditioning control assembly
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| PTC heater does not operate (w/ PTC Heater)
|
Proceed to "PTC Heater Circuit"
|
( )
|
| Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| ECM
|
( )
|
| Engine idle up does not occur or is continuous
|
Proceed to "CAN Communication System (for LHD)"
|
( )
|
| Proceed to "CAN Communication System (for RHD)"
|
( )
|
| Proceed to "Compressor Lock Sensor Circuit"
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Proceed to "ECD System (for 1VD-FTV [w/o DPF])"
|
( )
|
| Proceed to "ECD System (for 1VD-FTV [w/ DPF])"
|
( )
|
| Proceed to "SFI System (for 1GR-FE)"
|
( )
|
| Viscous with magnet clutch heater assembly does not operate when heater switch assembly is pushed while engine is cold*
|
Proceed to "Viscous Heater with Magnet Clutch Circuit"
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Blinking of air conditioning switch indicator
|
Air conditioning amplifier assembly
|
( )
|
| Engine idle up does not occur when idle up switch is pushed while engine is cold
|
Proceed to "Idle Up Switch Circuit"
|
( )
|
| Air conditioning amplifier assembly
|
( )
|
| Diagnostic trouble codes are not stored, and set mode is cleared when ignition switch is off
|
Proceed to "Back-up Power Source Circuit"
|
( )
|
| Air conditioning amplifier assembly
|
( )
|