The No. 1 cooler thermistor is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413 | An open or short in the No. 1 cooler thermistor circuit is detected for 8.5 minutes or more. | ·
No. 1 cooler thermistor ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Use the Data List to check if the No. 1 cooler thermistor is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F). |
The display is as specified in the normal condition.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
Remove the No. 1 cooler thermistor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
| *a | Sensor |
| *b | Resistance |
| *c | Allowable Range |
| *d | Temperature |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR(for LHD)>REMOVAL)
C
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR(for RHD)>DISASSEMBLY)
Remove the air conditioning harness assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z54-6 (TEA) - 2 | Always | Below 1 Ω |
| z54-5 (SGA) - 1 | Always | Below 1 Ω |
| z54-6 (TEA) - Body ground | Always | 10 kΩ or higher |
| z54-5 (SGA) - Body ground | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to No. 1 Cooler Thermistor) |
| *b | Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for LHD)>DISASSEMBLY)
C
(See pageVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for RHD)>DISASSEMBLY)