This is the power source circuit to operate the mobile wireless charger cradle assembly.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Disconnect the mobile wireless charger cradle assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E150-1 (PGND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E150-4 (B+) - Body ground | Power switch off | 11 to 14 V |
| E150-3 (ACC) - Body ground | Power switch on (ACC) | 11 to 14 V |
| Power switch off | Below 1 V |
OK