If the manual up/down function does not operate, there may be a malfunction in the power window regulator switch, front power window regulator motor RH or harness or connector.
Check for LIN communication system DTCs related to the power window control system (See page Power Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING).
LIN communication system DTCs are not output
OK
NG
(See pagePower Source / Network>NETWORKING>LIN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING)
Check if DTC B2312 is output (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>DTC CHECK / CLEAR).
DTC B2312 is not output.
OK
NG
Use the Data List to check if the power window regulator motor is functioning properly (See page Vehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| P Door P/W Up SW | Front passenger side power window manual up signal / ON or OFF | ON: Front passenger side power window manual up switch operated
OFF: Front passenger side power window switch not operated |
- |
| P Door P/W Down SW | Front passenger side power window manual down signal / ON or OFF | ON: Front passenger side power window manual down switch operated
OFF: Front passenger side power window switch not operated |
- |
The display changes according to operation of the power window regulator switch.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for LHD) | B |
| OK (for RHD) | C |
A
B
C
Disconnect the I3*1 or I25*2 switch connector.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I3-1 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I25-1 (GND) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the I4*1 or I12*2 motor connector.
*1: for LHD
*2: for RHD
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I4-2 (B) - Body ground | Always | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I12-2 (B) - Body ground | Always | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I4-1 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I12-1 (GND) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the I3*1 or I25*2 switch connector.
*1: for LHD
*2: for RHD
Disconnect the I4*1 or I12*2 motor connector.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I3-6 (UP) - I4-10 (UP) | Always | Below 1 Ω |
| I3-7 (DOWN) - I4-7 (DOWN) | Always | Below 1 Ω |
| I3-8 (AUTO) - I4-4 (AUTO) | Always | Below 1 Ω |
| I3-6 (UP) or I4-10 (UP) - Body ground | Always | 10 kΩ or higher |
| I3-7 (DOWN) or I4-7 (DOWN) - Body ground | Always | 10 kΩ or higher |
| I3-8 (AUTO) or I4-4 (AUTO) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I25-6 (UP) - I12-10 (UP) | Always | Below 1 Ω |
| I25-7 (DOWN) - I12-7 (DOWN) | Always | Below 1 Ω |
| I25-8 (AUTO) - I12-4 (AUTO) | Always | Below 1 Ω |
| I25-6 (UP) or I12-10 (UP) - Body ground | Always | 10 kΩ or higher |
| I25-7 (DOWN) or I12-7 (DOWN) - Body ground | Always | 10 kΩ or higher |
| I25-8 (AUTO) or I12-4 (AUTO) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the power window regulator switch (See page Vehicle Exterior>WINDOW / GLASS>FRONT PASSENGER SIDE POWER WINDOW SWITCH>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| I3-6 (UP) - I3-1 (GND) | Manual up operation | Below 1 Ω |
| I3-7 (DOWN) - I3-1 (GND) | Manual down operation | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| I25-6 (UP) - I11-1 (GND) | Manual up operation | Below 1 Ω |
| I25-7 (DOWN) - I11-1 (GND) | Manual down operation | Below 1 Ω |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for LHD) | B |
| OK (for RHD) | C |
A
B
C