Home › Engine / Hybrid System › 3UR-FE (ENGINE CONTROL) › SFI SYSTEM(w/ Secondary Air Injection System) › from 2017.08
RM2660E _51 Engine / Hybrid System _052775 3UR-FE ENGINE CONTROL _0327320 SFI SYSTEM(w/ Secondary Air Injection System) C

3UR-FE ENGINE CONTROL  SFI SYSTEM(w/ Secondary Air Injection System)  P0327  Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor)  P0328  Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor)  P032C  Knock Sensor 3 Circuit Low  P032D  Knock Sensor 3 Circuit High  P0332  Knock Sensor 2 Circuit Low Input (Bank 2)  P0333  Knock Sensor 2 Circuit High Input (Bank 2)  P033C  Knock Sensor 4 Circuit Low Input  P033D  Knock Sensor 4 Circuit High Input  


DESCRIPTION

A flat type knock sensor (non-resonant type) has a structure that can detect vibrations between approximately 6 kHz and 15 kHz.

Knock sensors are fitted onto the engine block to detect engine knocking.

The knock sensor contains a piezoelectric element which generates a voltage when it becomes deformed.

The voltage is generated when the engine block vibrates due to knocking. Any occurrence of engine knocking can be suppressed by delaying the ignition timing.

DTC Code DTC Detection Condition Trouble Area
P0327 The output voltage of the knock sensor (for Bank 1 Sensor 1) is 0.5 V or less (1 trip detection logic).
·

Short in knock sensor (for Bank 1 Sensor 1) circuit


·

Knock sensor (for Bank 1 Sensor 1)


·

ECM


P0328 The output voltage of the knock sensor (for Bank 1 Sensor 1) is 4.5 V or higher (1 trip detection logic).
·

Open in knock sensor (for Bank 1 Sensor 1) circuit


·

Knock sensor (for Bank 1 Sensor 1)


·

ECM


P0332 The output voltage of the knock sensor (for Bank 2 Sensor 1) is 0.5 V or less (1 trip detection logic).
·

Short in knock sensor (for Bank 2 Sensor1) circuit


·

Knock sensor (for Bank 2 Sensor 1)


·

ECM


P0333 The output voltage of the knock sensor (for Bank 2 Sensor 1) is 4.5 V or higher (1 trip detection logic).
·

Open in knock sensor (for Bank 2 Sensor1) circuit


·

Knock sensor (for Bank 2 Sensor 1)


·

ECM


P032C The output voltage of the knock sensor (for Bank 1 Sensor 2) is 0.5 V or less (1 trip detection logic).
·

Short in knock sensor (for Bank 1 Sensor 2) circuit


·

Knock sensor (for Bank 1 Sensor 2)


·

ECM


P032D The output voltage of the knock sensor (for Bank 1 Sensor 2) is 4.5 V or higher (1 trip detection logic).
·

Open in knock sensor (for Bank 1 Sensor 2) circuit


·

Knock sensor (for Bank 1 Sensor 2)


·

ECM


P033C The output voltage of the knock sensor (for Bank 2 Sensor 2) is 0.5 V or less (1 trip detection logic).
·

Short in knock sensor (for Bank 2 Sensor 2) circuit


·

Knock sensor (for Bank 2 Sensor 2)


·

ECM


P033D The output voltage of the knock sensor (for Bank 2 Sensor 2) is 4.5 V or higher (1 trip detection logic).
·

Open in knock sensor (for Bank 2 Sensor 2) circuit


·

Knock sensor (for Bank 2 Sensor 2)


·

ECM



HINT:

When any of DTCs P0327, P0328, P0332, P0333, P032C, P032D, P033C and P033D is stored, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is delayed to its maximum retardation. Fail-safe mode continues until the engine switch is turned off.


Reference: Inspection using an oscilloscope.

A150243E26
0.365,0.552 1.948,0.771 1.583,0.219 10 false KNK1 Signal Waveform 2.625,1.927 2.979,2.125 0.354,0.198 10 false GND 2.448,1.167 3.01,1.365 0.563,0.198 10 false 1 V/DIV. 1.042,2.844 1.885,3.042 0.844,0.198 10 false 1 msec./DIV.

Standard:
Tester Connection Tool Setting Condition Specified Condition
C45-94 (KNK1) - C45-93 (EKNK) 0.01 to 10 V/DIV.
0.01 to 10 msec./DIV.
Keep engine speed at 4000 rpm with warm engine The correct waveform is as shown
C45-117 (KNK2) - C45-116 (EKN2) 0.01 to 10 V/DIV.
0.01 to 10 msec./DIV.
Keep engine speed at 4000 rpm with warm engine The correct waveform is as shown
C45-92 (KNK3) - C45-91 (EKN3) 0.01 to 10 V/DIV.
0.01 to 10 msec./DIV.
Keep engine speed at 4000 rpm with warm engine The correct waveform is as shown
C45-115 (KNK4) - C45-114 (EKN4) 0.01 to 10 V/DIV.
0.01 to 10 msec./DIV.
Keep engine speed at 4000 rpm with warm engine The correct waveform is as shown


MONITOR DESCRIPTION

The knock sensor, located on the cylinder block, detects spark knock. When spark knock occurs, the piezoelectric element of the sensor vibrates. When the ECM detects a voltage in this frequency range, it retards the ignition timing to suppress the spark knock.

The ECM also senses background engine noise with the knock sensor and uses this noise to check for faults in the sensor. If the knock sensor signal level is too low for more than 10 seconds, or if the knock sensor output voltage is outside the normal range, the ECM interprets this as a fault in the knock sensor and stores DTC(s).

WIRING DIAGRAM

A165784E16
1.281,1.542 3.563,1.74 2.281,0.198 10 false Knock Sensor (for Bank 1 Sensor 1) 5.854,0.75 6.292,0.958 0.438,0.208 10 false KNK1 5.573,0.76 5.781,0.969 0.208,0.208 10 false 94 5.854,2.583 6.292,2.792 0.438,0.208 10 false KNK2 5.521,2.292 5.802,2.5 0.281,0.208 10 false 117 5.854,4.406 6.292,4.615 0.438,0.208 10 false KNK3 5.563,4.156 5.771,4.365 0.208,0.208 10 false 92 5.854,5.979 6.292,6.188 0.438,0.208 10 false KNK4 5.51,5.74 5.792,5.948 0.281,0.208 10 false 115 5.854,1.927 6.292,2.135 0.438,0.208 10 false EKNK 5.594,1.927 5.802,2.135 0.208,0.208 10 false 93 5.854,3.479 6.292,3.688 0.438,0.208 10 false EKN2 5.521,3.479 5.792,3.688 0.271,0.208 10 false 116 5.854,5.323 6.292,5.531 0.438,0.208 10 false EKN3 5.573,5.333 5.781,5.542 0.208,0.208 10 false 91 5.844,6.927 6.281,7.135 0.438,0.208 10 false EKN4 5.49,6.917 5.76,7.125 0.271,0.208 10 false 114 0.635,8.281 1.417,8.49 0.781,0.208 10 false *: Shielded 1.26,0.99 1.375,1.198 0.115,0.208 10 false 1 2.323,0.969 2.448,1.177 0.125,0.208 10 false 2 1.281,1.385 1.573,1.573 0.292,0.188 10 false U3 1.281,3.146 3.656,3.344 2.375,0.198 10 false Knock Sensor (for Bank 2 Sensor 1) 1.26,2.563 1.375,2.771 0.115,0.208 10 false 1 2.302,2.552 2.427,2.76 0.125,0.208 10 false 2 1.281,2.969 1.552,3.135 0.271,0.167 10 false U4 1.281,4.99 3.823,5.188 2.542,0.198 10 false Knock Sensor (for Bank 1 Sensor 2) 1.25,4.375 1.365,4.583 0.115,0.208 10 false 1 2.313,4.365 2.438,4.573 0.125,0.208 10 false 2 1.281,4.813 1.563,5.021 0.281,0.208 10 false U5 1.281,6.521 3.615,6.719 2.333,0.198 10 false Knock Sensor (for Bank 2 Sensor 2) 1.25,5.979 1.365,6.188 0.115,0.208 10 false 1 2.302,5.958 2.427,6.167 0.125,0.208 10 false 2 1.281,6.375 1.552,6.521 0.271,0.146 10 false U6 6.031,7.688 6.344,7.854 0.313,0.167 10 false C45 6.031,7.833 6.427,8 0.396,0.167 10 false ECM 4.542,0.677 4.688,0.865 0.146,0.188 10 false * 4.531,2.292 4.677,2.479 0.146,0.188 10 false * 4.521,4.083 4.667,4.271 0.146,0.188 10 false * 4.542,5.698 4.688,5.885 0.146,0.188 10 false *

CAUTION / NOTICE / HINT

HINT:
·

DTCs P0327 and P0328 are for the bank 1 sensor 1 knock sensor circuit.

·

DTCs P032C and P032D are for the bank 1 sensor 2 knock sensor circuit.

·

DTCs P0332 and P0333 are for the bank 2 sensor 1 knock sensor circuit.

·

DTCs P033C and P033D are for the bank 2 sensor 2 knock sensor circuit.

·

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

·

Bank 1 refers to the bank that includes the No. 1 cylinder*.

*: The No. 1 cylinder is the cylinder which is farthest from the transmission.

·

Bank 2 refers to the bank that does not include the No. 1 cylinder.



PROCEDURE

1.INSPECT KNOCK SENSOR
U163768E02
1.104,2.052 2.531,1.146 true 1.031,2.042 1.625,1.146 true 0.948,2.042 0.958,1.167 true 0.854,2.063 0.448,2.563 true 1.042,2.146 1.729,2.906 true 0.854,2.156 0.927,2.927 true 0.948,2.125 1.344,3.135 true 1.125,2.125 2.01,2.604 true 0.073,0.042 2.469,0.479 2.396,0.438 10 false Front view of wire harness connector: (to ECM) 0.146,0.896 0.51,1.083 0.365,0.188 10 false C45 2.406,0.958 3.146,1.167 0.74,0.208 10 false 94 (KNK1) 1.469,0.958 2.24,1.167 0.771,0.208 10 false 93 (EKNK) 2.073,2.521 2.906,2.729 0.833,0.208 10 false 117 (KNK2) 1.76,2.854 2.646,3.063 0.885,0.208 10 false 116 (EKN2) 0.635,0.969 1.469,1.177 0.833,0.208 10 false 92 (KNK3) 0.104,2.583 0.99,2.792 0.885,0.208 10 false 91 (EKN3) 1.198,3.135 2.031,3.333 0.833,0.198 10 false 115 (KNK4) 0.271,2.969 1.156,3.177 0.885,0.208 10 false 114 (EKN4)

a.

Disconnect the C45 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-94 (KNK1) - C45-93 (EKNK) 20°C (68°F) 120 to 280 kΩ
C45-117 (KNK2) - C45-116 (EKN2) 20°C (68°F) 120 to 280 kΩ
C45-92 (KNK3) - C45-91 (EKN3) 20°C (68°F) 120 to 280 kΩ
C45-115 (KNK4) - C45-114 (EKN4) 20°C (68°F) 120 to 280 kΩ


Result
Result Proceed to
NG A
OK B



A

2.CHECK HARNESS AND CONNECTOR (ECM - KNOCK SENSOR)

B

3.INSPECT ECM
2.CHECK HARNESS AND CONNECTOR (ECM - KNOCK SENSOR)
a.

Disconnect the C45 ECM connector.


b.

Disconnect the U3, U4, U5 or U6 knock sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
U3-2 - C45-94 (KNK1) Always Below 1 Ω
U3-1 - C45-93 (EKNK) Always Below 1 Ω
U4-2 - C45-117 (KNK2) Always Below 1 Ω
U4-1 - C45-116 (EKN2) Always Below 1 Ω
U5-2 - C45-92 (KNK3) Always Below 1 Ω
U5-1 - C45-91 (EKN3) Always Below 1 Ω
U6-2 - C45-115 (KNK4) Always Below 1 Ω
U6-1 - C45-114 (EKN4) Always Below 1 Ω
U3-2 or C45-94 (KNK1) - Body ground Always 10 kΩ or higher
U3-1 or C45-93 (EKNK) - Body ground Always 10 kΩ or higher
U4-2 or C45-117 (KNK2) - Body ground Always 10 kΩ or higher
U4-1 or C45-116 (EKN2) - Body ground Always 10 kΩ or higher
U5-2 or C45-92 (KNK3) - Body ground Always 10 kΩ or higher
U5-1 or C45-91 (EKN3) - Body ground Always 10 kΩ or higher
U6-2 or C45-115 (KNK4) - Body ground Always 10 kΩ or higher
U6-1 or C45-114 (EKN4) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT ECM
a.
U162845E02
0.125,0.073 2.479,0.417 2.354,0.344 10 false Front view of wire harness connector: (to Knock Sensor) 0.635,1.313 0.875,1.479 0.24,0.167 10 false U3 0.646,1.646 0.896,1.854 0.25,0.208 10 false U4 0.635,1.979 0.896,2.167 0.26,0.188 10 false U5 0.625,2.302 0.865,2.49 0.24,0.188 10 false U6

Disconnect the U3, U4, U5 or U6 knock sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
U3-1 - U3-2 Engine switch on (IG) 4.5 to 5.5 V
U4-1 - U4-2 Engine switch on (IG) 4.5 to 5.5 V
U5-1 - U5-2 Engine switch on (IG) 4.5 to 5.5 V
U6-1 - U6-2 Engine switch on (IG) 4.5 to 5.5 V




OK

NG