Output to the front seat cushion heater temperature sensor stops if one of the following occurs: 1) the temperature sensor is open or shorted; or 2) the temperature sensor is damaged and its output value does not change.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| B14C011 | Front Right Seat Heat Sensor Circuit Short to Ground | A short to ground in the temperature sensor circuit of the front right seat heater occurs for 4 seconds or more. |
·
Air conditioning amplifier assembly
·
Front seat cushion heater assembly RH
·
Harness or connector |
Air Conditioner | A |
| B14C015 | Front Right Seat Heat Sensor Circuit Short to Battery or Open | A short to +B or open in the temperature sensor circuit of the front right seat heater occurs for 4 seconds or more. |
·
Air conditioning amplifier assembly
·
Front seat cushion heater assembly RH
·
Harness or connector |
Air Conditioner | A |
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs.
| Result | Proceed to |
|---|---|
| B14C011 and B14C015 are not output | A |
| B14C011 or B14C015 is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
Pre-procedure1
Disconnect the I30 air conditioning amplifier assembly connector.
Disconnect the h9 front seat cushion heater assembly RH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(I30,h9)Location & Routingewd_type=routing;type=c,c;code=I30,h9 Click Connector(h9)Seat>Front Seat Wire RH>Front Seat Cushion Heater RH (Front Seat Cushion Pad RH)ewd_type=component;type=c;code=h9;pinno=4,5 |
||
| I30-12 (TSR) - h9-4 | Always | Below 1 Ω |
| I30-12 (TSR) or h9-4 - Other terminals and body ground | Always | 10 kΩ or higher |
| I30-1 (SG-6) - h9-5 | Always | Below 1 Ω |
| I30-1 (SG-6) or h9-5 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
OK
NG