The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air outlet damper to the appropriate position, which controls the rear air outlet switching. The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| B143B7F | Air Inlet Damper Control Servo Motor Actuator Stuck Off | Diagnosis Condition: During No. 1 blower damper servo sub-assembly operation Malfunction Status The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning Detection Time: Continuously for 30 seconds or more |
·
No. 1 blower damper servo sub-assembly
·
Air conditioning harness assembly
·
Blower assembly
·
Air conditioning amplifier assembly |
Memorized | Air Conditioner | A |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | No. 1 blower damper servo sub-assembly operating | ○ | ○ |
| Malfunction Status | Damper servo operation request signals are output but the damper position sensor value does not change | ○ | - |
| Damper servo operation request signals are output but the damper position sensor value is abnormal | - | ○ | |
| Detection Time | Continuously for 30 seconds or more | Continuously for 30 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
This DTC is also output for the damper link, damper lock, etc. Before performing inspection, perform servomotor initialization and check that there are no mechanical malfunctions.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION
This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION
Check that the No. 1 blower damper servo sub-assembly is installed correctly.
The No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for a wire harness caught between the links of the motors and dampers.
No wire harnesses are caught between the links of the motors and dampers.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Using the GTS, perform the following Active Test and read the Data List value.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly operation | Min: 128 Max: 384 |
for LHD (Single Layer):
Operates between 238 to 258
for LHD (Double Layer):
Operates between 258 to 290
for RHD:
Operates between 222 to 254 |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
- |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Using the GTS, perform the following Active Test and read the Data List value.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly operation | Min: 128 Max: 384 |
for LHD (Single Layer):
Operates between 238 to 258
for LHD (Double Layer):
Operates between 258 to 290
for RHD:
Operates between 222 to 254 |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Target Pulse | No. 1 blower damper servo sub-assembly target pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
- |
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
- |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Target Pulse |
| Air Inlet Damper Control Servo Motor Actual Pulse |
The target pulse value of the Data List matches the actual pulse.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
| Proceed to |
|---|
| NEXT |
NEXT
Using the GTS, perform the following Active Test and read the Data List value.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly operation | Min: 128 Max: 384 |
for LHD (Single Layer):
Operates between 238 to 258
for LHD (Double Layer):
Operates between 258 to 290
for RHD:
Operates between 222 to 254 |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | 128 to 384 |
for LHD (Single Layer):
·
Fresh: 238 (pulse)
·
Recirculation: 258 (pulse)
for LHD (Double Layer):
·
Fresh: 290 (pulse)
·
Recirculation: 258 (pulse)
for RHD:
·
Fresh: 222 (pulse)
·
Recirculation: 254 (pulse) |
- |
| Active Test Display |
|---|
| Air Inlet Damper Control Servo Motor |
| Data List Display |
|---|
| Air Inlet Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Using the GTS, perform the following Active Test and read the Data List value.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Right Air Mix Damper Control Servo Motor | No. 4 air conditioning radiator damper servo sub-assembly operation | Min: 128 Max: 384 |
Operates between 186 to 258 |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Front Right Air Mix Damper Control Servo Motor Actual Pulse | No. 4 air conditioning radiator damper servo sub-assembly actual pulse | 128 to 384 |
·
MAX COLD: 258 (pulse)
·
MAX HOT: 186 (pulse) |
- |
| Active Test Display |
|---|
| Front Right Air Mix Damper Control Servo Motor |
| Data List Display |
|---|
| Front Right Air Mix Damper Control Servo Motor Actual Pulse |
The value of the Data List changes in accordance with the operation of the Active Test.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the No. 1 blower damper servo sub-assembly.
Procedure1
Operate the dampers by hand.
The dampers are easily operated by hand.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG