Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467925 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B143B7F  Air Inlet Damper Control Servo Motor Actuator Stuck Off  


DESCRIPTION

The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air outlet damper to the appropriate position, which controls the rear air outlet switching. The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
B143B7F Air Inlet Damper Control Servo Motor Actuator Stuck Off Diagnosis Condition:

During No. 1 blower damper servo sub-assembly operation


Malfunction Status

The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning


Detection Time:

Continuously for 30 seconds or more


·

No. 1 blower damper servo sub-assembly

·

Air conditioning harness assembly

·

Blower assembly

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition No. 1 blower damper servo sub-assembly operating ○ ○
Malfunction Status Damper servo operation request signals are output but the damper position sensor value does not change ○ -
Damper servo operation request signals are output but the damper position sensor value is abnormal - ○
Detection Time Continuously for 30 seconds or more Continuously for 30 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

E343005E33
2.573,1.333 2.885,1.531 0.313,0.198 10 false IC 0.229,2.552 1.969,3.208 1.74,0.656 10 false No. 1 Blower Damper Servo Sub-assembly 2.75,2.729 5.354,2.927 2.604,0.198 10 false Air Conditioning Harness Assembly 5.563,2.531 5.875,2.729 0.313,0.198 10 false z16 5.531,2.729 7.104,3.417 1.573,0.688 10 false Air Conditioning Amplifier Assembly 0.781,3.344 3.104,3.688 2.323,0.344 10 false : LIN Communication Line 5.323,0.615 5.479,0.813 0.156,0.198 10 false 4 5.323,1.156 5.479,1.354 0.156,0.198 10 false 3 5.333,1.802 5.49,2 0.156,0.198 10 false 2 6.615,0.604 6.927,0.802 0.313,0.198 10 false +B 6.771,1.333 7.083,1.531 0.313,0.198 10 false IC 5.531,0.615 6.302,0.813 0.771,0.198 10 false BBUS 5.552,1.219 6.01,1.417 0.458,0.198 10 false BUS 5.552,1.802 6.323,2 0.771,0.198 10 false BUS G

CAUTION / NOTICE / HINT

NOTICE:
·

This DTC is also output for the damper link, damper lock, etc. Before performing inspection, perform servomotor initialization and check that there are no mechanical malfunctions.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION

·

This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION



PROCEDURE

1.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
a.

Check that the No. 1 blower damper servo sub-assembly is installed correctly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY


OK:

The No. 1 blower damper servo sub-assembly is installed correctly.



Result:
Proceed to
OK
NG



OK

2.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)

NG

REINSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

2.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
a.

Check for a wire harness caught between the links of the motors and dampers.

OK:

No wire harnesses are caught between the links of the motors and dampers.



Result:
Proceed to
OK
NG



OK

3.PERFORM ACTIVE TEST USING GTS

NG

REMOVE PINCHED WIRE HARNESS

3.PERFORM ACTIVE TEST USING GTS
a.

Using the GTS, perform the following Active Test and read the Data List value.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly operation Min: 128
Max: 384
for LHD (Single Layer):

Operates between 238 to 258


for LHD (Double Layer):

Operates between 258 to 290


for RHD:

Operates between 222 to 254


Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Air Inlet Damper Control Servo Motor Actual Pulse No. 1 blower damper servo sub-assembly actual pulse 128 to 384
for LHD (Single Layer):
·

Fresh: 238 (pulse)

·

Recirculation: 258 (pulse)


for LHD (Double Layer):
·

Fresh: 290 (pulse)

·

Recirculation: 258 (pulse)


for RHD:
·

Fresh: 222 (pulse)

·

Recirculation: 254 (pulse)


-
Body Electrical > Air Conditioner > Active Test
Active Test Display
Air Inlet Damper Control Servo Motor
Data List Display
Air Inlet Damper Control Servo Motor Actual Pulse
50004 450 32 213
OK:

The value of the Data List changes in accordance with the operation of the Active Test.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS

NG

7.PERFORM ACTIVE TEST USING GTS
4.PERFORM ACTIVE TEST USING GTS
a.

Using the GTS, perform the following Active Test and read the Data List value.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly operation Min: 128
Max: 384
for LHD (Single Layer):

Operates between 238 to 258


for LHD (Double Layer):

Operates between 258 to 290


for RHD:

Operates between 222 to 254


Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Air Inlet Damper Control Servo Motor Target Pulse No. 1 blower damper servo sub-assembly target pulse 128 to 384
for LHD (Single Layer):
·

Fresh: 238 (pulse)

·

Recirculation: 258 (pulse)


for LHD (Double Layer):
·

Fresh: 290 (pulse)

·

Recirculation: 258 (pulse)


for RHD:
·

Fresh: 222 (pulse)

·

Recirculation: 254 (pulse)


-
Air Inlet Damper Control Servo Motor Actual Pulse No. 1 blower damper servo sub-assembly actual pulse 128 to 384
for LHD (Single Layer):
·

Fresh: 238 (pulse)

·

Recirculation: 258 (pulse)


for LHD (Double Layer):
·

Fresh: 290 (pulse)

·

Recirculation: 258 (pulse)


for RHD:
·

Fresh: 222 (pulse)

·

Recirculation: 254 (pulse)


-
Body Electrical > Air Conditioner > Active Test
Active Test Display
Air Inlet Damper Control Servo Motor
Data List Display
Air Inlet Damper Control Servo Motor Target Pulse
Air Inlet Damper Control Servo Motor Actual Pulse
50004 450 32 212,213
OK:

The target pulse value of the Data List matches the actual pulse.



Result:
Proceed to
OK
NG



OK

NG

5.REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
5.REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NEXT

6.PERFORM ACTIVE TEST USING GTS
6.PERFORM ACTIVE TEST USING GTS
a.

Using the GTS, perform the following Active Test and read the Data List value.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly operation Min: 128
Max: 384
for LHD (Single Layer):

Operates between 238 to 258


for LHD (Double Layer):

Operates between 258 to 290


for RHD:

Operates between 222 to 254


Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Air Inlet Damper Control Servo Motor Actual Pulse No. 1 blower damper servo sub-assembly actual pulse 128 to 384
for LHD (Single Layer):
·

Fresh: 238 (pulse)

·

Recirculation: 258 (pulse)


for LHD (Double Layer):
·

Fresh: 290 (pulse)

·

Recirculation: 258 (pulse)


for RHD:
·

Fresh: 222 (pulse)

·

Recirculation: 254 (pulse)


-
Body Electrical > Air Conditioner > Active Test
Active Test Display
Air Inlet Damper Control Servo Motor
Data List Display
Air Inlet Damper Control Servo Motor Actual Pulse
50004 450 32 213
OK:

The value of the Data List changes in accordance with the operation of the Active Test.



Result:
Proceed to
OK
NG



OK

END

NG

7.PERFORM ACTIVE TEST USING GTS
a.

Using the GTS, perform the following Active Test and read the Data List value.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Right Air Mix Damper Control Servo Motor No. 4 air conditioning radiator damper servo sub-assembly operation Min: 128
Max: 384
Operates between 186 to 258
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Front Right Air Mix Damper Control Servo Motor Actual Pulse No. 4 air conditioning radiator damper servo sub-assembly actual pulse 128 to 384
·

MAX COLD: 258 (pulse)

·

MAX HOT: 186 (pulse)


-
Body Electrical > Air Conditioner > Active Test
Active Test Display
Front Right Air Mix Damper Control Servo Motor
Data List Display
Front Right Air Mix Damper Control Servo Motor Actual Pulse
50004 450 28 205
OK:

The value of the Data List changes in accordance with the operation of the Active Test.



Result:
Proceed to
OK
NG



OK

5.REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

8.CHECK BLOWER ASSEMBLY (DAMPER)
8.CHECK BLOWER ASSEMBLY (DAMPER)

Pre-procedure1

a.

Remove the No. 1 blower damper servo sub-assembly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY



Procedure1

b.

Operate the dampers by hand.

OK:

The dampers are easily operated by hand.


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPLACE BLOWER ASSEMBLY