Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM38G0E _58 Vehicle Interior _100766 HEATING / AIR CONDITIONING _0467925 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  P053511  Evaporator Temperature Sensor Circuit Short to Ground  


DESCRIPTION

The No. 1 cooler thermistor is installed to the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the e No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
P053511 Evaporator Temperature Sensor Circuit Short to Ground Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Short (GND) in evaporator temperature sensor circuit


Detection Time:

Continuously for 4 seconds or more


·

No. 1 cooler thermistor

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

WIRING DIAGRAM

E316646E56
2.969,0.969 3.25,1.208 0.281,0.24 10 false 1 2.979,0.5 3.26,0.74 0.281,0.24 10 false 2 1.135,1.542 2.698,1.938 1.563,0.396 10 false No. 1 Cooler Thermistor 3.042,1.406 4.594,1.781 1.552,0.375 10 false Air Conditioning Harness Assembly 4.823,1.792 7.094,2.104 2.271,0.313 10 false Air Conditioning Amplifier Assembly 4.563,0.5 4.844,0.74 0.281,0.24 10 false 6 4.563,0.99 4.844,1.229 0.281,0.24 10 false 5 4.813,0.469 5.333,0.75 0.521,0.281 10 false TE 4.823,0.948 5.292,1.198 0.469,0.25 10 false SG-3 5.885,0.292 6.167,0.531 0.281,0.24 10 false 5 V 6.156,0.625 6.438,0.865 0.281,0.24 10 false AD 4.802,1.625 5.125,1.854 0.323,0.229 10 false z16

PROCEDURE

1.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)

Pre-procedure1

a.
A226261C89
0.917,1.771 1.281,2 0.365,0.229 10 false *1 2.667,1.771 3.031,2 0.365,0.229 10 false *2 1.99,0.698 2.448,0.969 0.458,0.271 10 false TE 1.948,1.01 2.469,1.25 0.521,0.24 10 false SG-3
*1 No. 1 Cooler Thermistor
*2 Air Conditioning Amplifier Assembly


Disconnect the No. 1 cooler thermistor connector.


Procedure1

b.

According to the display on the GTS, read the Data List.

Body Electrical > Air Conditioner > Data List
Tester Display
Evaporator Fin Thermistor
50003 450 105
OK:
GTS Display Specified Condition
Evaporator Fin Thermistor -327.68°C (-557.82°F)


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

NG

2.CHECK AIR CONDITIONING HARNESS ASSEMBLY
2.CHECK AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Remove the air conditioning harness assembly.

HINT:


E378688C46
0.917,0.833 1.333,1.083 0.417,0.25 1.333,1.583 1.667,1.583 1.667,1.583 1.781,1.26 true 2.323,1.583 1.99,1.583 1.99,1.583 1.927,1.25 true 1.167,0.229 1.479,0.427 0.313,0.198 10 false *a 4.469,0.302 4.781,0.5 0.313,0.198 10 false *b 1.01,0.896 1.323,1.094 0.313,0.198 10 false z16 0.979,1.49 1.469,1.708 0.49,0.219 10 false SG-3 2.396,1.479 2.885,1.698 0.49,0.219 10 false TE
*a Front view of air conditioning harness assembly connector
(to Air Conditioning Amplifier Assembly)
*b Front view of air conditioning harness assembly connector
(to No. 1 Cooler Thermistor)



Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z16)Location & Routing

Click Connector(z16)Instrument Panel>other>Air Conditioning Unit Assembly , Air Conditioning Amplifier Assembly

2 or z16-6 (TE) - Other terminals and body ground Always 10 kΩ or higher
1 or z16-5 (SG-3) - Other terminals and body ground Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG