Home › Engine / Hybrid System › V35A-FTS (ENGINE CONTROL) › SFI SYSTEM
RM38G0E _51 Engine / Hybrid System _100526 V35A-FTS ENGINE CONTROL _0470271 SFI SYSTEM C

V35A-FTS ENGINE CONTROL  SFI SYSTEM  P024300  Turbocharger/Supercharger Wastegate Actuator "A"  P024700  Turbocharger/Supercharger Wastegate Actuator "B"  P25B372  Turbocharger/Supercharger Wastegate "A" Actuator Stuck Open  P25B473  Turbocharger/Supercharger Wastegate "A" Actuator Stuck Closed  P25B572  Turbocharger/Supercharger Wastegate "B" Actuator Stuck Open  P25B673  Turbocharger/Supercharger Wastegate "B" Actuator Stuck Closed  


DESCRIPTION

The waste gate valve is installed in the turbine housing. The ECM uses duty control to operate the DC motor inside the waste gate valve actuator assembly to control the opening amount according to the operation status.

The waste gate valve opening amount is detected by the waste gate valve position sensor and transmitted to the ECM. When high load engine operation is necessary, the waste gate valve closes to increase the torque and improve the response during acceleration. In the low-engine-load operating range, the waste gate valve opens to lower the exhaust manifold pressure to further reduce pumping losses and improve fuel economy.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Note
P024300 Turbocharger/Supercharger Wastegate Actuator "A" Both of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is outside the specified range or position sensor voltage at waste gate valve fully closed contact is outside the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is at or above a specified value


·

Open or short in waste gate valve actuator assembly (bank 1) circuit

·

Turbocharger sub-assembly (bank 1)

·

ECM


- SAE: P0243
P024700 Turbocharger/Supercharger Wastegate Actuator "B" Both of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is outside the specified range or position sensor voltage at waste gate valve fully closed contact is outside the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is at or above a specified value


·

Open or short in waste gate valve actuator assembly (bank 2) circuit

·

Turbocharger sub-assembly (bank 2)

·

ECM


- SAE: P0247
P25B372 Turbocharger/Supercharger Wastegate "A" Actuator Stuck Open All of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is within the specified range

·

Position sensor voltage at waste gate valve fully closed contact is outside the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is smaller than the specified value


·

Open or short in waste gate valve actuator assembly (bank 1) circuit

·

Turbocharger sub-assembly (bank 1)

·

ECM


- SAE: P25B3
P25B473 Turbocharger/Supercharger Wastegate "A" Actuator Stuck Closed All of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is outside the specified range

·

Position sensor voltage at waste gate valve fully closed contact is within the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is smaller than the specified value


·

Open or short in waste gate valve actuator assembly (bank 1) circuit

·

Turbocharger sub-assembly (bank 1)

·

ECM


- SAE: P25B4
P25B572 Turbocharger/Supercharger Wastegate "B" Actuator Stuck Open All of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is within the specified range

·

Position sensor voltage at waste gate valve fully closed contact is outside the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is smaller than the specified value


·

Open or short in waste gate valve actuator assembly (bank 2) circuit

·

Turbocharger sub-assembly (bank 2)

·

ECM


- SAE: P25B5
P25B673 Turbocharger/Supercharger Wastegate "B" Actuator Stuck Closed All of the following conditions are met during waste gate valve active detection (1 trip detection logic):
·

Position sensor voltage at waste gate valve fully open contact is outside the specified range

·

Position sensor voltage at waste gate valve fully closed contact is within the specified range

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact is smaller than the specified value


·

Open or short in waste gate valve actuator assembly (bank 2) circuit

·

Turbocharger sub-assembly (bank 2)

·

ECM


- SAE: P25B6

MONITOR DESCRIPTION

WASTE GATE VALVE ACTIVE DETECTION



While the vehicle is stopped after engine warm-up, the ECM forcibly operates the waste gate valve to make contact for 3 seconds each in the fully open and fully closed positions while the engine is idling with accelerator pedal fully released. The ECM judges from the output voltage of the position sensor whether the following 3 items are within the specified range.

·

Position sensor voltage at waste gate valve fully open contact

·

Position sensor voltage at waste gate valve fully closed contact

·

Difference between position sensor voltages at waste gate valve fully open and fully closed contact


WASTE GATE VALVE MALFUNCTION (P024300, P024700)


When any or all of the output voltages during waste gate valve fully open contact and fully closed contact and the difference in the voltage change amount are outside the specified range, the ECM stores a DTC.


WASTE GATE VALVE ACTUATOR STUCK OPEN (P25B372, P25B572)


During waste gate valve active detection, when the output voltage at waste gate valve fully open contact is within the specified range, the output voltage at fully closed contact is outside the specified range and the voltage change amount is smaller than the specified value, the valve is judged to be stuck open and the ECM stores a DTC.


WASTE GATE VALVE ACTUATOR STUCK CLOSED (P25B473, P25B673)


During waste gate valve active detection, when the output voltage at waste gate valve fully closed contact is within the specified range, the output voltage at fully open contact is outside the specified range and the voltage change amount is smaller than the specified value, the valve is judged to be stuck closed and the ECM stores a DTC.


MONITOR STRATEGY

Required Sensors/Components Waste gate valve actuator assembly
Frequency of Operation Once per driving cycle

TYPICAL ENABLING CONDITIONS

Battery voltage 11 V or higher
Engine coolant temperature 70°C (158°F) or higher
Idle On
Engine speed 400 to 2000 rpm
Vehicle speed 20 km/h (12.4 mph) or less
Atmospheric pressure 76 kPa(abs) [11.02 psi(abs)] or higher
Intake air amount More than 15 g

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON.

3.

Turn the GTS on.

4.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

5.

Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.

6.

Turn the ignition switch off and wait for at least 30 seconds.

7.

Turn the ignition switch to ON.

8.

Turn the GTS on.

9.

Start the engine.

10.

Idle the engine for 1 minute or more.

HINT:

This is for performing waste gate valve active detection.


11.

Enter the following menus: Powertrain / Engine / Trouble Codes.

12.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



13.

Enter the following menus: Powertrain / Engine / Utility / All Readiness.

14.

Input the DTC: P024300, P024700, P025B372, P025B473, P025B572 or P25B673.

15.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions



HINT:
·

If the judgment result is NORMAL, the system is normal.

·

If the judgment result is ABNORMAL, the system is malfunctioning.




WIRING DIAGRAM

CAUTION / NOTICE / HINT

HINT:
·

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

·

Bank 1 refers to the bank that includes the No. 1 cylinder*.

*: The No. 1 cylinder is the cylinder which is farthest from the transmission.

·

Bank 2 refers to the bank that does not include the No. 1 cylinder.

DTC Suspected Area
P024300, P25B372, P25B473 Bank 1
P024700, P25B572, P25B673 Bank 2



PROCEDURE

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P024300, P024700, P25B372, P25B473, P25B572 AND/OR P25B673)
a.

Read the DTCs.

Powertrain > Engine > Trouble Codes
50001 372
Result:
Result Proceed to
P024300, P024700, P25B372, P25B473, P25B572 and/or P25B673 is output A
P024300, P024700, P25B372, P25B473, P25B572 and/or P25B673 and other DTCs are output B


HINT:

If any DTCs other than P024300, P024700, P25B372, P25B473, P25B572 and/or P25B673 are output, troubleshoot those DTCs first.




A

2.CLEAR DTC

B

GO TO DTC CHART

2.CLEAR DTC
a.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 372

b.

Turn the ignition switch off and wait for at least 30 seconds.


Result:
Proceed to
NEXT



NEXT

3.READ VALUE USING GTS (WASTEGATE VALVE)
3.READ VALUE USING GTS (WASTEGATE VALVE)
a.

Start the engine.


b.

Allow the engine to idle until Coolant Temperature reaches 75°C (167°F) or higher.


c.

Turn the ignition switch off and wait for at least 30 seconds.


d.

Set the snapshot function and start saving the data.

Powertrain > Engine > Data List
Tester Display
Wastegate Valve Control Duty Ratio Bank2
Wastegate Valve Control Duty Ratio Bank1
Wastegate Valve Sensor Voltage when Fully Closed Bank1
Wastegate Valve Sensor Voltage when Fully Closed Bank2
Wastegate Valve Sensor Voltage when Fully Open Bank1
Wastegate Valve Sensor Voltage when Fully Open Bank2
Wastegate Valve Actuator Current Bank1
Wastegate Valve Actuator Current Bank2
Wastegate Valve Position Bank1
Wastegate Valve Position Bank2
50003 372 875,878,793,795,794,796,797,798,799,800

e.

Start the engine, run it at idle for 1 minute or more and then save the data.


f.

Display the saved data and read the Data List.

Standard:
Standard Condition GTS Display Specified Condition
1 When waste gate valve fully open contact Wastegate Valve Sensor Voltage when Fully Open Bank1 (Bank2) 0.8 to 1.6 V
2 When waste gate valve fully closed contact Wastegate Valve Sensor Voltage when Fully Closed Bank1 (Bank2) 3.3 to 4.4 V
3 From waste gate valve fully open to fully closed contact Wastegate Valve Sensor Voltage when Fully Closed Bank1 (Bank2) - Wastegate Valve Sensor Voltage when Fully Open Bank1 (Bank2) 1.8 to 3.8 V
4 From waste gate valve fully open to fully closed contact - 3.8 V / sec. or higher



Result:
Result Proceed to
Waste gate valve does not move (Standards 1 to 4 are not met) A
Waste gate valve abnormal sliding (Standard 4 is not met, Standards 1 to 3 are met)
Waste gate valve moves smoothly but fully closed contact position is outside the specified range (Standard 4 is met, Standard 1, 2 or 3 is not met) B
Waste gate valve moves smoothly (All Standards from 1 to 4 are met) C


HINT:

Perform "Inspection After Repair" after replacing the turbocharger sub-assembly.

Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION



A

4.PERFORM ACTIVE TEST USING GTS (CONTROL THE WASTEGATE VALVE DUTY RATIO)

B

C

6.CLEAR DTC
4.PERFORM ACTIVE TEST USING GTS (CONTROL THE WASTEGATE VALVE DUTY RATIO)
a.

Operate the Active Test at 10% until the wastegate valve makes contact, and then operate it at 30% and read the Data List.

Powertrain > Engine > Active Test
Active Test Display
Control the Wastegate Valve Duty Ratio Bank1
Data List Display
Wastegate Valve Actuator Current Bank1
50004 372 65 797
Powertrain > Engine > Active Test
Active Test Display
Control the Wastegate Valve Duty Ratio Bank2
Data List Display
Wastegate Valve Actuator Current Bank2
50004 372 62 798
Result:
GTS Operation Wastegate Valve Actuator Current Bank1 or Wastegate Valve Actuator Current Bank2
30% 0.7 A or higher



Result:
Proceed to
OK
NG


HINT:

Perform "Inspection After Repair" after replacing the turbocharger sub-assembly.

Click hereEngine / Hybrid System>V35A-FTS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION



OK

NG

5.CHECK HARNESS AND CONNECTOR (WASTE GATE VALVE ACTUATOR ASSEMBLY- ECM)
5.CHECK HARNESS AND CONNECTOR (WASTE GATE VALVE ACTUATOR ASSEMBLY- ECM)
a.

Disconnect the waste gate valve actuator assembly connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(C45,C37,C46)Location & Routing

Click Connector(C45)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>No. 1 Turbocharger Sub-Assembly

Click Connector(C37)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>ECM

Click Connector(C46)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>No. 2 Turbocharger Sub-Assembly

C45-2 (WG1+) - C37-1 (WGM+) Always Below 1 Ω
C45-1 (WG1-) - C37-2 (WGM-) Always Below 1 Ω
C46-1 (WG2+) - C37-20 (WG2+) Always Below 1 Ω
C46-2 (WG2-) - C37-21 (WG2-) Always Below 1 Ω
C45-2 (WG1+) or C37-1 (WGM+) - Body ground and other terminals Always 10 kΩ or higher
C45-1 (WG1-) or C37-2 (WGM-) - Body ground and other terminals Always 10 kΩ or higher
C46-1 (WG2+) or C37-20 (WG2+) - Body ground and other terminals Always 10 kΩ or higher
C46-2 (WG2-) or C37-21 (WG2-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CLEAR DTC
a.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 372

b.

Turn the ignition switch off and wait for at least 30 seconds.


Result:
Proceed to
NEXT



NEXT

7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.


b.

Perform the All Readiness.

Powertrain > Engine > Utility
Tester Display
All Readiness
50005 372 1020

c.

Input the DTC: P024300, P024700, P25B372, P25B473, P25B572 or P25B673.


d.

Check the DTC judgment result.

Result:
GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions





Result:
Proceed to
NEXT



NEXT

END