| *1 | HOOD TO COWL TOP SEAL | - | - |
|
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf) |
|
N*m (kgf*cm, ft.*lbf): Specified torque |
28800 1.INSTALL BATTERY
28899 2.INSTALL BATTERY INSULATOR
74405 3.INSTALL NO. 2 BATTERY CLAMP SUB-ASSEMBLY
4.CONNECT CABLE TO POSITIVE BATTERY TERMINAL
5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
55781D 6.CONNECT COWL TOP VENTILATOR LOUVER RH
7. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART