RM38G0E _53 Suspension _100546 SUSPENSION CONTROL _0470891 ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM C

SUSPENSION CONTROL  ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM  C183912  Rr Stabilizer Solenoid A Control Circuit Circuit Short to Battery  


DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area DTC Output from
C183912 Rr Stabilizer Solenoid A Control Circuit Circuit Short to Battery Short circuit detected in solenoid valve
·

Stabilizer control with accumulator housing assembly

·

Harness or connector

·

Stabilizer control ECU


Electronic-Kinetic Dynamic Suspension System (E-KDSS)

WIRING DIAGRAM

C457025E03
0.635,2.49 1.094,2.677 0.458,0.188 10 false vV1 0.625,2.677 2.792,3.229 2.167,0.552 10 false Stabilizer Control with Accumulator Housing Assembly 5.302,2.188 5.76,2.375 0.458,0.188 10 false Q13 5.313,2.365 6.823,2.573 1.51,0.208 10 false Stabilizer Control ECU 5.5,1.406 5.958,1.594 0.458,0.188 10 false RUP- 5.49,0.635 5.948,0.823 0.458,0.188 10 false RUP+ 2.958,0.5 3.115,0.698 0.156,0.198 10 false 1 2.958,1.292 3.115,1.49 0.156,0.198 10 false 2 5.271,0.521 5.427,0.719 0.156,0.198 10 false 6 5.26,1.302 5.417,1.5 0.156,0.198 10 false 5 0.625,1.635 2.927,1.875 2.302,0.24 10 false Rear Upper Chamber Solenoid Valve

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SUPPLY - STABILIZER CONTROL ECU)
a.

Disconnect the Q13 stabilizer control ECU connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(Q13)Location & Routing

Click Connector(Q13)Body>Air Conditioning Wiring Harness Assembly / Floor Wire / Step Rear Floor Wire RH / Theft Warning Sensor Cord Sub-Assembly>Stabilizer Control ECU

Q13-5 (RUP-) - Body ground Always Below 1 V
Q13-6 (RUP+) - Body ground Always Below 1 V



c.

Connect the Q13 stabilizer control ECU connector.


Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - BODY GROUND)
a.

Disconnect the Q13 stabilizer control ECU connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(Q13)Location & Routing

Click Connector(Q13)Body>Air Conditioning Wiring Harness Assembly / Floor Wire / Step Rear Floor Wire RH / Theft Warning Sensor Cord Sub-Assembly>Stabilizer Control ECU

Q13-5 (RUP-) - Body ground Always 10 kΩ or higher
Q13-6 (RUP+) - Body ground Always 10 kΩ or higher



c.

Connect the Q13 stabilizer control ECU connector.


Result:
Proceed to
OK
NG



OK

3.INSPECT STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY (REAR UPPER CHAMBER SOLENOID VALVE)

NG

4.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY - BODY GROUND)
3.INSPECT STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY (REAR UPPER CHAMBER SOLENOID VALVE)
a.
C457010C03
0.104,0.083 0.417,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)


Disconnect the vV1 stabilizer control with accumulator housing assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 4.58 to 5.02 Ω



c.

Connect the vV1 stabilizer control with accumulator housing assembly connector.


Result:
Proceed to
OK
NG



OK

REPLACE STABILIZER CONTROL ECU

NG

REPLACE STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY

4.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY - BODY GROUND)
a.
C457010C03
0.104,0.083 0.417,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)


Disconnect the vV1 stabilizer control with accumulator housing assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - Body ground Always 10 kΩ or higher
2 - Body ground Always 10 kΩ or higher



c.

Connect the vV1 stabilizer control with accumulator housing assembly connector.


Result:
Proceed to
OK
NG



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

REPLACE STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY