| *1 | OIL COOLER TUBE SUB-ASSEMBLY | - | - |
The necessary procedures(adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator assembly removal/installation are shown below.
When the cable is disconnected/reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
1. PRECAUTION
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
3.REMOVE RADIATOR WITH COOLER CONDENSER ASSEMBLY
82121 4.DISCONNECT ENGINE WIRE
16603B 5.REMOVE IDLER PULLEY SUB-ASSEMBLY
27060 6.REMOVE GENERATOR ASSEMBLY
Remove the bolt and disconnect the oil cooler tube sub-assembly from the generator assembly.
Remove the 2 bolts and 2 nuts.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and generator assembly.