| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 1 | UREA INJECTOR ASSEMBLY | 23720 | ( ) |
- | - |
| 2 | INSULATOR | 77697C | - | - | - |
| 3 | EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY | 25051 | - | - | - |
| *1 | Urea Injector Clamp | - | - |
|
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf) | ● | Non-reusable part |
23720 1.INSTALL UREA INJECTOR ASSEMBLY
| *a | 6.0 mm (0.236 in.) | *b | Cutaway view |
| *c | 2.5 mm (0.098 in.) or more | *d | Bottom |
Install the urea injector clamp and tighten the nut until the clamp clearance is 6 mm (0.236 in.).
Tighten the clamp nut with pushing the urea injector assembly toward the top of the vehicle.
Measure the clearance the urea injector and clamp.
2.5 mm (0.098 in.) or more
The removed urea injector assembly, urea injector clamp and nut are not reusable.
77697C 2.INSTALL INSULATOR
25051 3.INSTALL EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY