| ● | Non-reusable part | - | - |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 5 | NO. 1 SENSOR BRACKET | 89439D | - | - | - |
| 6 | NO. 2 NITROGEN OXIDES SENSOR | 89463D | - | - | - |
17117A 1.REMOVE INTAKE PIPE INSULATOR
17169 2.REMOVE NO. 3 EXHAUST MANIFOLD HEAT INSULATOR
89463C 3.REMOVE NO. 1 NITROGEN OXIDES SENSOR
Disconnect the connector from the No. 1 nitrogen oxides sensor.
Detach the sensor wire from the bracket.
Loosen the nitrogen oxides sensor probe.
Remove the 2 bolts and No. 1 nitrogen oxides sensor.
82715W 4.REMOVE WIRING HARNESS CLAMP BRACKET
89439D 5.REMOVE NO. 1 SENSOR BRACKET
89463D 6.REMOVE NO. 2 NITROGEN OXIDES SENSOR
Using SST, disconnect the No. 2 nitrogen oxides sensor.
Disconnect the connector from the No. 2 nitrogen oxides sensor.
Remove the 2 nuts, detach the clamp and then remove the No. 2 nitrogen oxides sensor.