The Intake Air Temperature (IAT) sensor is built into the charge air cooler and senses the IAT. A built-in thermistor in the sensor changes its resistance value according to the intake air temperature. The lower the intake air temperature, the greater the thermistor resistance value. The higher the intake air temperature, the lower the thermistor resistance value (see Fig. 1).
The sensor is connected to the ECM. The 5 V power source voltage in the ECM is applied to the sensor from terminal THIA via resistor R. Resistor R and the sensor are connected in series. When the resistance value of the sensor changes in accordance with changes in the IAT, the potential at terminal THIA also changes. Based on this signal, the ECM corrects the fuel injection volume to improve driveability with a cold engine.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P1495 | Intake Air Temperature Sensor 1 Circuit | Open or short in intake air temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
·
Open or short in intake air temperature (IAT) sensor circuit
·
IAT sensor
·
ECM |
Comes on | DTC stored |
| P1496 | Intake Air Temperature Sensor 1 Circuit Low | Short in IAT sensor circuit for 0.5 seconds (1 trip detection logic) |
·
Short in IAT sensor circuit
·
IAT sensor
·
ECM |
Comes on | DTC stored |
| P1497 | Intake Air Temperature Sensor 1 Circuit High | Open in IAT sensor circuit for 0.5 seconds (1 trip detection logic) |
·
Open in IAT sensor circuit
·
IAT sensor
·
ECM |
Comes on | DTC stored |
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).
If DTCs relating to different systems are output, and they share terminal E2 as their ground, check this ground circuit first.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Turn the ignition switch ON and turn the GTS ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air Temp (Turbo).
| Tester Display |
|---|
| Intake Air Temp (Turbo) |
Read the value.
Same as air temperature near intake manifold.
| Result | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| OK (same as air temperature near intake manifold) | C |
If there is an open circuit, the GTS indicates -40°C (-40°F).
If there is a short circuit, the GTS indicates 140°C (284°F) or more.
A
B
C
Click hereEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM>CHECK FOR INTERMITTENT PROBLEMS
| *1 | IAT Sensor |
| *2 | ECM |
| *a | Front view of wire harness connector (to IAT Sensor) |
Disconnect the C60 intake air temperature (IAT) sensor connector.
Connect terminals 1 and 2 of the IAT sensor wire harness side connector.
Connect the GTS to the DLC3.
Turn the ignition switch ON and turn the GTS ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air Temp (Turbo).
| Tester Display |
|---|
| Intake Air Temp (Turbo) |
Read the value.
140°C (284°F) or higher
| Proceed to |
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector (to IAT Sensor) |
| *b | Front view of wire harness connector (to ECM) |
Disconnect the C60 IAT sensor connector.
Disconnect the C39 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C60-2 - C39-74 (THIA) | Always | Below 1 Ω |
| C60-1 - C39-75 (E2) | Always | Below 1 Ω |
| Proceed to |
| OK |
| NG |
OK
NG
Disconnect the C60 IAT sensor connector.
Connect the GTS to the DLC3.
Turn the ignition switch ON and turn the GTS ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air Temp (Turbo).
| Tester Display |
|---|
| Intake Air Temp (Turbo) |
Read the value.
-40°C (-40°F)
| Proceed to |
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector (to IAT Sensor) |
| *b | Front view of wire harness connector (to ECM) |
Disconnect the C60 IAT sensor connector.
Disconnect the C39 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C60-2 or C39-74 (THIA) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
| OK |
| NG |
OK