The Air Fuel Ratio (A/F) sensor generates a voltage* that corresponds to the actual air fuel ratio. This sensor voltage is used to provide the ECM with feedback so that it can control the air fuel ratio. The ECM determines the deviation from the stoichiometric air fuel ratio, and regulates the fuel injection time. If the A/F sensor malfunctions, the ECM is unable to control the air fuel ratio accurately.
The A/F sensor is the planar type and is integrated with a heater, which heats the solid electrolyte (zirconia element). This heater is controlled by the ECM. When the intake air volume is low (the exhaust gas temperature is low), a current flows into the heater to heat the sensor in order to facilitate accurate oxygen concentration detection. In addition, the sensor and heater portions are the narrow type. The heat generated by the heater is conducted to the solid electrolyte through the alumina, therefore the sensor activation is accelerated.
In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air fuel ratio must be precisely controlled so that it is always close to the stoichiometric level.
*: The value changes inside the ECM. Since the A/F sensor is a current output element, the current is converted into a voltage inside the ECM. Any measurements taken at the A/F sensor or ECM connectors will show a constant voltage.
When either of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the A/F sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.
Although the DTC titles say oxygen sensor, these DTCs relate to the Air Fuel Ratio (A/F) sensor.
Sensor 1 refers to the sensor mounted in front of the Three-Way Catalytic Converter (TWC) and located near the engine assembly.
The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The A/F sensor heater circuit uses a relay on the +B side of the circuit.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0031 | Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) | The Air Fuel ratio (A/F) sensor heater current is below 0.8 A (1 trip detection logic). |
·
Open in Air Fuel Ratio (A/F) sensor (bank 1 sensor1) heater circuit
·
A/F sensor heater (bank 1 sensor 1)
·
A/F relay
·
ECM |
Comes on | DTC stored |
| P0032 | Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1) | An Air Fuel ratio (A/F) sensor heater current failure (1 trip detection logic). |
·
Short in A/F sensor (bank 1 sensor1) heater circuit
·
A/F sensor heater (bank 1 sensor 1)
·
A/F relay
·
ECM |
Comes on | DTC stored |
| P0051 | Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1) | The Air Fuel ratio (A/F) sensor heater current is below 0.8 A (1 trip detection logic). |
·
Open in Air Fuel Ratio (A/F) sensor (bank 2 sensor1) heater circuit
·
A/F sensor heater (bank 2 sensor 1)
·
A/F relay
·
ECM |
Comes on | DTC stored |
| P0052 | Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1) | An Air Fuel ratio (A/F) sensor heater current failure (1 trip detection logic). |
·
Short in A/F sensor (bank 2 sensor1) heater circuit
·
A/F sensor heater (bank 2 sensor 1)
·
A/F relay
·
ECM |
Comes on | DTC stored |
| P101D | A/F Sensor Heater Circuit Performance Bank 1 Sensor 1 Stuck ON | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM | Comes on | DTC stored |
| P103D | A/F Sensor Heater Circuit Performance Bank 2 Sensor 1 Stuck ON | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM | Comes on | DTC stored |
The ECM uses information from the Air Fuel Ratio (A/F) sensor to regulate the air fuel ratio and keep it close to the stoichiometric level. This maximizes the ability of the Three-Way Catalytic Converter (TWC) to purify the exhaust gases.
The A/F sensor detects oxygen levels in the exhaust gas and transmits the information to the ECM. The inner surface of the sensor element is exposed to the outside air. The outer surface of the sensor element is exposed to the exhaust gas. The sensor element is made of platinum coated zirconia and includes an integrated heating element.
The zirconia element generates a small voltage when there is a large difference in the oxygen concentrations between the exhaust gas and outside air. The platinum coating amplifies this voltage generation.
The A/F sensor is more efficient when heated. When the exhaust gas temperature is low, the sensor cannot generate useful voltage signals without supplementary heating. The ECM regulates the supplementary heating using a duty-cycle approach to adjust the average current in the sensor heater element. If the heater current is outside the normal range, the signal transmitted by the A/F sensor becomes inaccurate, as a result, the ECM is unable to regulate air fuel ratio properly.
When the current in the A/F sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor heater and stores a DTC.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the GTS on [A].
Start the engine and idle it for 5 minutes or more [B].
With the vehicle stationary, depress the accelerator pedal and maintain an engine speed of 3000 rpm for 1 minute [C].
Idle the engine for 5 minutes or more [D].
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [E].
Read the pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0031, P0032, P0051, P0052, P101D or P103D.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
·
DTC judgment completed
·
System normal |
| ABNORMAL |
·
DTC judgment completed
·
System abnormal |
| INCOMPLETE |
·
DTC judgment not completed
·
Perform driving pattern after confirming DTC enabling conditions |
| N/A |
·
Unable to perform DTC judgment
·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform steps [B] through [E] again.
Refer to DTC P2237.
Click hereEngine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>P2237
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Inspect the air fuel ratio sensor.
Click hereEngine / Hybrid System>1GR-FE (ENGINE CONTROL)>AIR FUEL RATIO SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *A | Bank 1 |
| *B | Bank 2 |
| *a | Front view of wire harness connector (to Air Fuel Ratio Sensor) |
Disconnect the air fuel ratio sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C21-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| C19-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the air fuel ratio sensor (bank 1 sensor 1) connector.
Disconnect the air fuel ratio sensor (bank 2 sensor 1) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C21-1 (HA1A) - C39-86 (HA1A) | Always | Below 1 Ω |
| C19-1 (HA2A) - C39-109 (HA2A) | Always | Below 1 Ω |
| C21-1 (HA1A) or C39-86 (HA1A) - Body ground | Always | 10 kΩ or higher |
| C19-1 (HA2A) or C39-109 (HA2A) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs.
Start the engine.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC P0031, P0032, P0051, P0052, P101D or P103D is output | B |
A
B
Inspect the A/F relay.
Click hereEngine / Hybrid System>1GR-FE (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the air fuel ratio sensor (bank 1 sensor 1) connector.
Disconnect the air fuel ratio sensor (bank 2 sensor 1) connector.
Remove the A/F relay from the Engine Room Relay Block Assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C21-2 (+B) - A/F relay terminal 3 | Always | Below 1 Ω |
| C19-2 (+B) - A/F relay terminal 3 | Always | Below 1 Ω |
| C21-2 (+B) or A/F relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| C19-2 (+B) or A/F relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Engine Room Relay Block Assembly |
| *2 | A/F Relay |
Remove the A/F relay from the Engine Room Relay Block Assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A/F relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the A/F relay from the Engine Room Relay Block Assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A/F relay terminal 2 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG