Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM
RM37H0E _59 Vehicle Exterior _093353 LIGHTING (EXT) _0448416 LIGHTING SYSTEM J

LIGHTING (EXT)  LIGHTING SYSTEM  Hazard Warning Switch Circuit  


DESCRIPTION

The combination meter assembly receives the hazard warning signal switch assembly ON signal and controls the operation of the hazard warning lights.

WIRING DIAGRAM

E346682E20
5.344,1.375 5.958,1.573 0.615,0.198 10 false HAZ 5.885,1.448 6.5,1.646 0.615,0.198 10 false I/F 6.448,1.469 7.063,1.667 0.615,0.198 10 false CPU 5.042,1.365 5.656,1.563 0.615,0.198 10 false 2 2.438,1.375 3.052,1.573 0.615,0.198 10 false 5 0.802,1.396 1.417,1.594 0.615,0.198 10 false 4 1.01,1.396 1.625,1.594 0.615,0.198 10 false E 2.115,1.385 2.729,1.583 0.615,0.198 10 false TB 0.854,1.969 2.938,2.469 2.083,0.5 10 false D99 0.854,2.167 3.917,2.583 3.063,0.417 10 false Hazard Warning Signal Switch Assembly 5.24,2.448 7.104,2.906 1.865,0.458 10 false D42 5.25,2.615 7.125,3.083 1.875,0.469 10 false Combination Meter Assembly

CAUTION / NOTICE / HINT

NOTICE:

When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.


PROCEDURE

1.READ VALUE USING GTS
a.

Using the GTS, read the Data List.

Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Hazard Flasher Switch Hazard warning signal switch assembly OFF or ON OFF: Hazard warning signal switch assembly off
ON: Hazard warning signal switch assembly on
-
Body Electrical > Combination Meter > Data List
Tester Display
Hazard Flasher Switch
50003 409 39
OK:

Normal conditions listed above are displayed.



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
2.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY

OK

3.CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)

NG

REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY

3.CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
a.

Disconnect the D99 hazard warning signal switch assembly connector.


b.

Disconnect the D42 combination meter assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(D99,D42)Location & Routing

Click Connector(D99)Instrument Panel>Instrument Panel Wire>Hazard Warning Signal Switch Assembly

Click Connector(D42)Instrument Panel>Instrument Panel Wire>Combination Meter Assembly

D99-5 (TB) - D42-2 (HAZ) Always Below 1 Ω
D99-4 (E) - Body ground Always Below 1 Ω
D99-5 (TB) or D42-2 (HAZ) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR