The pop up hood warning light is located in the combination meter assembly.
When the SRS is normal, the pop up hood warning light comes on for approximately 6 seconds after the ignition switch is turned from off to ON, and then goes off automatically.
If there is a malfunction in the SRS, the pop up hood warning light comes on to inform the driver of a problem.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
After replacing the airbag ECU assembly, refer to initialization.
Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE
Inspect the fuses for circuits related to this system before performing the following procedure.
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
Measure the auxiliary battery voltage with the ignition switch off.
11 to 14 V
It may be possible to tell whether the auxiliary battery is discharged by operating the horn.
If the voltage is below 11 V, recharge or replace the auxiliary battery before proceeding to the next step.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 60 seconds.
Check that the connector is properly connected to the airbag ECU assembly.
The connector is properly connected.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Combination Meter Assembly |
| *2 | Airbag ECU Assembly |
| *3 | Wire Harness |
Disconnect the airbag ECU assembly connector.
Check that the terminals of the connectors are not deformed or damaged.
The terminals are not deformed or damaged.
Check that the connectors are not loose, deformed or damaged.
The connector locking button is not disengaged, and the claw of the lock is not deformed or damaged.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 |
||
| D41-36 (IG2) - Body ground | Ignition switch ON | 11 to 14 V |
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 |
||
| D41-33 (E1)- Body ground | Always | Below 1 Ω |
| D41-32 (E2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 60 seconds.
Connect the connector to the combination meter assembly.
Disconnect the connector from the airbag ECU assembly.
Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON and check the pop up hood warning light condition.
After the primary check period, the pop up hood warning light turns off for approximately 10 seconds and then turns back on.
The primary check period is approximately 6 seconds after the ignition switch is turned to ON.
| Proceed to |
|---|
| OK |
| NG |
OK
NG