N*m (kgf*cm, ft.*lbf): Specified torque | - | - |
88211B
1.INSTALL MILLIMETER WAVE RADAR SENSOR ASSEMBLY
|
Screw |
|
Bolt |
|
Connector | - | - |
Temporarily install the millimeter wave radar sensor assembly with attach the guide.
Tighten the 2 bolts and screw in the order shown in the illustration.
Connect the connector.
53295
2.INSTALL LOWER RADIATOR AIR DEFLECTOR
53291B
3.INSTALL RADIATOR COVER PLATE
53292A
4.INSTALL UPPER RADIATOR SUPPORT SEAL
88211B
5.ADJUST MILLIMETER WAVE RADAR SENSOR ASSEMBLY
When the millimeter wave radar sensor assembly is replaced with a new one, adjustment of the radar sensor beam axis must be performed.
Millimeter wave radar sensor assembly learning can be performed by using either Target Adjustment (Triangle Target) or Target Adjustment (Flat Surface Target) or Driving Adjustment.
Target Adjustment (Triangle Target):
Target Adjustment (Flat Surface Target):
Driving Adjustment:
Click hereADAS / AD>ADVANCED DRIVER ASSISTANCE SYSTEM>MILLIMETER WAVE RADAR SENSOR>DRIVING ADJUSTMENT