Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM37H0E _58 Vehicle Interior _095300 HEATING / AIR CONDITIONING _0455055 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1412  Ambient Temperature Sensor Circuit  


DESCRIPTION

The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (3.3 V) to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
B1412 Ambient Temperature Sensor Circuit
·

Diagnosis condition: None

·

Malfunction status: Open or short in ambient temperature sensor circuit

·

Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)


·

Thermistor assembly

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized Air Conditioner A

HINT:

If the ambient temperature is approximately -52.9°C (-63.22°F) or lower, DTC B1412 may be output even though the system is normal.


WIRING DIAGRAM

E407114E09
4.542,1.604 5,1.802 0.458,0.198 10 false D80 4.542,1.781 6.896,2.104 2.354,0.323 10 false Air Conditioning Amplifier Assembly 4.781,0.531 5.24,0.729 0.458,0.198 10 false TAM 4.792,1 5.25,1.198 0.458,0.198 10 false SG-2 4.479,1.01 4.896,1.177 0.417,0.167 10 false 14 4.542,0.531 4.958,0.698 0.417,0.167 10 false 1 2.99,0.531 3.406,0.698 0.417,0.167 10 false 2 3,1.01 3.417,1.177 0.417,0.167 10 false 1 1.365,1.51 1.823,1.708 0.458,0.198 10 false A35 1.354,1.677 3.708,2 2.354,0.323 10 false Thermistor Assembly 5.708,0.198 6.167,0.396 0.458,0.198 10 false 5 V 6.177,0.646 6.635,0.844 0.458,0.198 10 false AD 2.688,0.521 3.104,0.688 0.417,0.167 10 false + 2.688,1 3.104,1.167 0.417,0.167 10 false -

PROCEDURE

1.READ VALUE USING GTS (AMBIENT TEMP SENSOR)
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly system malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Body Electrical > Air Conditioner > Data List
Tester Display
Ambient Temp Sensor
50003 121 2
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT THERMISTOR ASSEMBLY
2.INSPECT THERMISTOR ASSEMBLY

OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - THERMISTOR ASSEMBLY)

NG

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - THERMISTOR ASSEMBLY)

Pre-procedure1

a.

Disconnect the D80 air conditioning amplifier assembly connector.


b.

Disconnect the A35 thermistor assembly connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(D80,A35)Location & Routing

Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assembly

Click Connector(A35)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>Thermistor Assembly

D80-1 (TAM) - A35-2 Always Below 1 Ω
D80-14 (SG-2) - A35-1 Always Below 1 Ω
D80-1 (TAM) or A35-2 - Other terminals and body ground Always 10 kΩ or higher
D80-14 (SG-2) or A35-1 - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR