This DTC is stored when the blind spot monitor sensor RH judges that there is a communication problem with the blind spot monitor sensor LH.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| U0232 | Lost Communication with Blind Spot Monitor Slave Module | The blind spot monitor sensor (master) cannot receive signals from the blind spot monitor sensor (slave) | ·
Open or short in CAN bus main wire or connector ·
Open or short in No. 7 CAN junction connector ·
Blind spot monitor sensor RH ·
Power source circuit of blind spot monitor sensor LH ·
Blind spot monitor sensor LH ground circuit ·
Blind spot monitor sensor LH |
Blind Spot Monitor Master | B |
When checking for DTCs, make sure that the blind spot monitor system is turned on.
Inspect the fuses for circuits related to this system before performing the following procedure.
Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
Using the GTS, check for DTCs according to the prompts on the screen.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| U117787 and U117887 are output | B |
A
B
Pre-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Procedure1
| *a | Component with harness connected
(No. 7 CAN Junction Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=3,14 |
||
| G130-3 (CANH) - G130-14 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| G130-3 (CANH) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-14 (CANL) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-3 (CANH) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G130-14 (CANL) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Result | Proceed to |
|---|---|
| G130-3 (CANH) - G130-14 (CANL) is more than or equal to 70 Ω | A |
| G130-3 (CANH) - G130-14 (CANL) is less than or equal to 54 Ω | B |
| G130-3 (CANH) - Body ground is less than or equal to 200 Ω | C |
| G130-14 (CANL) - Body ground is less than or equal to 200 Ω | D |
| G130-3 (CANH) - +B is less than or equal to 6 kΩ | E |
| G130-14 (CANL) - +B is less than or equal to 6 kΩ | F |
| None of the above conditions are met | G |
Post-procedure1
None
A
B
C
D
E
F
G
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=2,13 |
||
| G130-2 (CANH) - G130-13 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=3,14 |
||
| G130-3 (CANH) - G130-14 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G60 blind spot monitor sensor LH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G60)Location & Routingewd_type=routing;type=c;code=G60 Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=G60;pinno=1,6 |
||
| G60-1 (CA2P) - G60-6 (CA2N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G56 blind spot monitor sensor RH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G56)Location & Routingewd_type=routing;type=c;code=G56 Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RHewd_type=component;type=c;code=G56;pinno=1,6 |
||
| G56-1 (CA2P) -G56-6 (CA2N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=2,13 |
||
| G130-2 (CANH) - G130-13 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=3,14 |
||
| G130-3 (CANH) - G130-14 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G60 blind spot monitor sensor LH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G60)Location & Routingewd_type=routing;type=c;code=G60 Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=G60;pinno=1,6 |
||
| G60-1 (CA2P) - G60-6 (CA2N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G56 blind spot monitor sensor RH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G56)Location & Routingewd_type=routing;type=c;code=G56 Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RHewd_type=component;type=c;code=G56;pinno=1,6 |
||
| G56-1 (CA2P) -G56-6 (CA2N) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=2,13 |
||
| G130-2 (CANH) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-13 (CANL) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-2 (CANH) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G130-13 (CANL) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G130 No. 7 CAN junction connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G130)Location & Routingewd_type=routing;type=c;code=G130 Click Connector(G130)Body>Floor Wire / No. 3 Floor Wire>No. 7 CAN Junction Connectorewd_type=component;type=c;code=G130;pinno=3,14 |
||
| G130-3 (CANH) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-14 (CANL) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G130-3 (CANH) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G130-14 (CANL) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G60 blind spot monitor sensor LH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G60)Location & Routingewd_type=routing;type=c;code=G60 Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=G60;pinno=1,6 |
||
| G60-1 (CA2P) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G60-6 (CA2N) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G60-1 (CA2P) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G60-6 (CA2N) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the G130 No. 7 CAN junction connector.
Disconnect the G56 blind spot monitor sensor RH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G56)Location & Routingewd_type=routing;type=c;code=G56 Click Connector(G56)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor RHewd_type=component;type=c;code=G56;pinno=1,6 |
||
| G56-1 (CA2P) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G56-6 (CA2N) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G56-1 (CA2P) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G56-6 (CA2N) - +B | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the cable to the negative (-) auxiliary battery terminal.
Disconnect the G60 blind spot monitor sensor LH connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G60)Location & Routingewd_type=routing;type=c;code=G60 Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=G60;pinno=10 |
||
| G60-10 (BLGD) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
OK
NG
Pre-procedure1
Disconnect the G60 blind spot monitor sensor LH connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G60)Location & Routingewd_type=routing;type=c;code=G60 Click Connector(G60)Body>Floor Wire / No. 3 Floor Wire>Blind Spot Monitor Sensor LHewd_type=component;type=c;code=G60;pinno=5 |
||
| G60-5 (BLB) - Body ground | Ignition switch ON | 11 to 14 V |
| G60-5 (BLB) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
Replace the blind spot monitor sensor LH.
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
B