This DTC is stored when CXPI communication between the room light control relay and main body ECU (multiplex network body ECU) stops for 10 seconds or more.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| B12A0 | Lost Communication with Illumination Module "A" | No communication between main body ECU (multiplex network body ECU) and room light control relay (for Front Side) for 10 seconds or more | ·
Main body ECU (multiplex network body ECU) ·
Room light control relay (for Front Side) ·
Harness or connector |
Main Body | A |
| B12A1 | Lost Communication with Illumination Module "B" | No communication between main body ECU (multiplex network body ECU) and room light control relay (for Rear Side) for 10 seconds or more | ·
Main body ECU (multiplex network body ECU) ·
Room light control relay (for Rear Side) ·
Harness or connector |
Main Body | A |
Inspect the fuses for circuits related to this system before performing the following procedure.
Recognition code registration is necessary when replacing the main body ECU (multiplex network body ECU).
If the main body ECU (multiplex network body ECU) is replaced, refer to the Service Bulletin.
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Some parts must be initialized and set when replacing or removing and installing parts.
Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE
Pre-procedure1
Clear the DTCs.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| B12A0 and B12A1 are output | A |
| B12A0 is output | B |
| B12A1 is output | C |
Post-procedure1
None
A
B
C
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D115 room light control relay (for Front Side) connector.
Disconnect the G76 room light control relay (for Rear Side) connector.
Disconnect the D12 main body ECU (multiplex network body ECU) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D115,D12)Location & Routingewd_type=routing;type=c,c;code=D115,D12 Click Connector(D115)Instrument Panel>Instrument Panel Wire>Room Light Control Relayewd_type=component;type=c;code=D115;pinno=10 Click Connector(D12)Instrument Panel>Instrument Panel Wire>Main Body ECUewd_type=component;type=c;code=D12;pinno=11 |
||
| D115-10 (CXPI) - D12-11 (CXP2) | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| D115-10 (CXPI) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the D115 room light control relay (for Front Side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D115)Location & Routingewd_type=routing;type=c;code=D115 Click Connector(D115)Instrument Panel>Instrument Panel Wire>Room Light Control Relayewd_type=component;type=c;code=D115;pinno=9 |
||
| D115-9 (E) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D115)Location & Routingewd_type=routing;type=c;code=D115 Click Connector(D115)Instrument Panel>Instrument Panel Wire>Room Light Control Relayewd_type=component;type=c;code=D115;pinno=14 |
||
| D115-14 (ILA4) - Body ground | Ignition switch off | 10 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D115 room light control relay (for Front Side) connector.
Disconnect the G76 room light control relay (for Rear Side) connector.
Disconnect the D12 main body ECU (multiplex network body ECU) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D115,D12)Location & Routingewd_type=routing;type=c,c;code=D115,D12 Click Connector(D115)Instrument Panel>Instrument Panel Wire>Room Light Control Relayewd_type=component;type=c;code=D115;pinno=10 Click Connector(D12)Instrument Panel>Instrument Panel Wire>Main Body ECUewd_type=component;type=c;code=D12;pinno=11 |
||
| D115-10 (CXPI) - D12-11 (CXP2) | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| D115-10 (CXPI) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the G76 room light control relay (for Rear Side) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G76)Location & Routingewd_type=routing;type=c;code=G76 Click Connector(G76)Body>Floor Wire / No. 3 Floor Wire>Rear Room Light Control Relayewd_type=component;type=c;code=G76;pinno=9 |
||
| G76-9 (BU-) - Body ground | Always | Below 1 Ω |
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G76)Location & Routingewd_type=routing;type=c;code=G76 Click Connector(G76)Body>Floor Wire / No. 3 Floor Wire>Rear Room Light Control Relayewd_type=component;type=c;code=G76;pinno=7 |
||
| G76-7 (BU+) - Body ground | Ignition switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the D115 room light control relay (for Front Side) connector.
Disconnect the G76 room light control relay (for Rear Side) connector.
Disconnect the D12 main body ECU (multiplex network body ECU) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G76,D12)Location & Routingewd_type=routing;type=c,c;code=G76,D12 Click Connector(G76)Body>Floor Wire / No. 3 Floor Wire>Rear Room Light Control Relayewd_type=component;type=c;code=G76;pinno=10 Click Connector(D12)Instrument Panel>Instrument Panel Wire>Main Body ECUewd_type=component;type=c;code=D12;pinno=11 |
||
| G76-10 (CXPI) - D12-11 (CXP2) | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| G76-10 (CXPI) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG