The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced when inspecting auxiliary battery are shown below.
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
| Effect/Inoperative Function when Necessary Procedure not Performed | Necessary Procedure | Link |
|---|---|---|
| Air Conditioning System | After the ignition switch is turned to ON, the servo motor and expansion valve standard position is recognized. | - |
1. PRECAUTION
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
2.CHECK AUXILIARY BATTERY
Check that the auxiliary battery cables are connected to the correct terminals.
If they are not, connect them properly.
Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
Check the electrolyte level in each cell.
If the electrolyte level is below the lower line, replace the auxiliary battery.
3.CHECK AUXILIARY BATTERY VOLTAGE
Pre-procedure1
Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
Procedure1
Measure the auxiliary battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal | 20°C (68°F), Ignition switch off | 12.0 V or higher |
If it is below the standard value, charge the auxiliary battery.
Post-procedure1
None
4.RECHARGE AUXILIARY BATTERY
Pre-procedure1
Recharge the auxiliary battery.
Recharge the auxiliary battery according to the charger's instructions.
Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.
| Charge Method | Charging Current |
|---|---|
| Normal | Below 5 A |
| Quick | Below 15 A |
Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
Procedure1
Measure the auxiliary battery voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal | 20°C (68°F), Ignition switch off | 12.0 V or higher |
If it is below the standard value, charge the auxiliary battery.
Post-procedure1
None
5.CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
Check that the auxiliary battery terminals are not loose or corroded.
If a terminal is loose or corroded, tighten or clean the terminal.
Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.
Below 1 Ω
If the result is not as specified, replace the fusible link or fuse as necessary.
6.CHECK AMD TERMINAL
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
Pre-procedure1
Remove the service plug grip.
Procedure1
| *A | for LHD |
| *B | for RHD |
Check that the AMD terminal is connected securely, and there is no contact problem.
If there are any arc marks, replace the affected parts.
Check that the nut for the AMD terminal is tightened to the specified torque.
If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.
Post-procedure1
Install the service plug grip.
7.CHECK DC/DC CONVERTER FUNCTION
Pre-procedure1
| *a | Probe Direction |
| *b | Current Flowing into Auxiliary Battery |
Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.
Turn the ignition switch on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.
Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.
Procedure1
| *a | Probe Direction |
| *b | Current Flowing from Auxiliary Battery |
Measure the current and voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) auxiliary battery cable | Ignition switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.) |
0 A or less |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal | Ignition switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.) |
12.5 to 15 V |
If the result is not as specified, replace the inverter with converter assembly.
Post-procedure1
None