Home › Power Source / Network › BATTERY / CHARGING › CHARGING SYSTEM
RM37H0E _57 Power Source / Network _097006 BATTERY / CHARGING _0461862 CHARGING SYSTEM G

BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced when inspecting auxiliary battery are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (Click here)

HINT:

When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

Learning completes when vehicle is driven
Effect/Inoperative Function when Necessary Procedure not Performed Necessary Procedure Link
Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more. (Click here)
Pre-collision system
Adaptive high beam system

Learning completes when vehicle is operated normally
Effect/Inoperative Function when Necessary Procedure not Performed Necessary Procedure Link
Air Conditioning System After the ignition switch is turned to ON, the servo motor and expansion valve standard position is recognized. -


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY


Hide 2.CHECK AUXILIARY BATTERY

a.

Check that the auxiliary battery cables are connected to the correct terminals.

If they are not, connect them properly.


b.

Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.


c.

Check the electrolyte level in each cell.

·

If the electrolyte level is below the lower line, replace the auxiliary battery.



Hide 3.CHECK AUXILIARY BATTERY VOLTAGE

Pre-procedure1

a.

Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


Procedure1

a.

Measure the auxiliary battery voltage according to the value(s) in the table below.

Result:
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher


HINT:

If it is below the standard value, charge the auxiliary battery.



Post-procedure1

a.

None


Hide 4.RECHARGE AUXILIARY BATTERY

Pre-procedure1

a.

Recharge the auxiliary battery.

HINT:
·

Recharge the auxiliary battery according to the charger's instructions.

·

Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.


Charge Method Charging Current
Normal Below 5 A
Quick Below 15 A



b.

Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


Procedure1

a.

Measure the auxiliary battery voltage according to the value(s) in the table below.

Result:
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher


HINT:

If it is below the standard value, charge the auxiliary battery.



Post-procedure1

a.

None


Hide 5.CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE

a.

Check that the auxiliary battery terminals are not loose or corroded.

Torque:
Positive (+) Auxiliary Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) Auxiliary Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)

If a terminal is loose or corroded, tighten or clean the terminal.


b.

Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.

Standard Resistance:

Below 1 Ω


If the result is not as specified, replace the fusible link or fuse as necessary.


Hide 6.CHECK AMD TERMINAL

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



Pre-procedure1

a.

Procedure1

a.
A484572C01
0.042,0.031 0.281,0.198 0.24,0.167 10 true *A 0.052,2.469 0.302,2.646 0.25,0.177 10 true *B
*A for LHD
*B for RHD


Check that the AMD terminal is connected securely, and there is no contact problem.

If there are any arc marks, replace the affected parts.


b.

Check that the nut for the AMD terminal is tightened to the specified torque.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.


Post-procedure1

a.

Hide 7.CHECK DC/DC CONVERTER FUNCTION

Pre-procedure1

a.
A111747C13
0.802,0.979 1.146,0.646 1.146,0.646 1.281,0.646 false 1.177,1.26 0.896,1.656 0.896,1.656 0.75,1.656 false 1.302,0.563 1.49,0.719 0.188,0.156 10 *a 0.552,1.563 0.75,1.708 0.198,0.146 10 *b
*a Probe Direction
*b Current Flowing into Auxiliary Battery


Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.


b.

Turn the ignition switch on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.


c.

Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.


Procedure1

a.
A314451C01
0.729,0.854 0.865,0.417 0.865,0.417 1.083,0.417 false 0.719,1.76 0.938,1.76 0.938,1.76 1.229,1.313 false 1.135,0.333 1.448,0.49 0.313,0.156 10 false *a 0.563,1.688 0.875,1.844 0.313,0.156 10 false *b
*a Probe Direction
*b Current Flowing from Auxiliary Battery


Measure the current and voltage according to the value(s) in the table below.

Result:
Current flowing from auxiliary battery
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery cable Ignition switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
0 A or less

Auxiliary battery voltage
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal Ignition switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
12.5 to 15 V


If the result is not as specified, replace the inverter with converter assembly.


Post-procedure1

a.

None