Refer to the description for DTC P0A001C.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A0011 | Motor Electronics Coolant Temperature Sensor "A" Circuit Short to Ground | Short to ground in the coolant temperature sensor circuit
(1 trip detection logic) |
Inverter with converter assembly | Master Warning:
Comes on |
EV | A |
| P0A0015 | Motor Electronics Coolant Temperature Sensor "A" Circuit Short to Battery or Open | Open or short to +B in the coolant temperature sensor circuit
(1 trip detection logic) |
Inverter with converter assembly | Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P0A0011 | Inverter Coolant Water Temperature |
| P0A0015 |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
After the repair, clear the DTCs. If "Inverter Coolant Water Temperature" does not show an abnormal value (110°C (230°F) or -50°C (-58°F)) when the ignition switch is turned to ON, the condition is judged as normal.
(If a Low malfunction exists in the coolant temperature sensor wiring, 110°C (230°F) is displayed and if a High malfunction exists, -50°C (-58°F) is displayed.)
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
| Proceed to |
|---|
| NEXT |
NEXT