MALFUNCTION DESCRIPTION
The EV control ECU (main CPU) monitors the battery ECU assembly.
The cause of this malfunction may be the following:
Battery ECU assembly malfunction
The EV control ECU (main CPU) monitors the battery ECU assembly and stores this DTC when it detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation | The battery ECU assembly value received by the EV control ECU (main CPU) exceeds the threshold for a certain period of time.
(1 trip detection logic) |
Battery ECU assembly | Master Warning:
Comes on |
EV | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY) and wait for 10 seconds or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Read the current DTCs.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A1F94 is output | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B