The MG ECU, which is built into in the inverter with converter assembly, detects the temperature of the FC air compressor motor inverter using the temperature sensor built into the inverter with converter assembly. The inverter cooling system operates independently of the engine cooling system. The MG ECU uses signals from the FC air compressor motor inverter temperature sensor to check the effectiveness of the inverter cooling system. If necessary, the MG ECU will limit inverter output to help prevent inverter overheating. The ECU also detects malfunctions in the FC air compressor motor inverter temperature sensor and its wiring.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D7011 | FC Air Compressor Inverter Temperature Sensor Circuit Short to Ground | Short to ground in the FC air compressor motor inverter temperature sensor signal circuit
(1 trip detection logic) |
Inverter with converter assembly | Master Warning:
Comes on |
EV | A |
| P1D7015 | FC Air Compressor Inverter Temperature Sensor Circuit Short to Battery or Open | Open or short to +B in the FC air compressor motor inverter temperature sensor signal circuit
(1 trip detection logic) |
Inverter with converter assembly | Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P1D7011 | FC Air Compressor Inverter Temperature |
| P1D7015 |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Turn the ignition switch to ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
| Proceed to |
|---|
| NEXT |