| *1 | ROCKER PANEL MOULDING LH | - | - |
| ● | Non-reusable part | - | - |
Use the same procedure for the RH and LH sides.
The procedure listed below is for the LH side.
75861C
2.INSTALL ROCKER PANEL MOULDING PAD
| *a | Mark-off Line | - | - |
|
Installation Area | - | - |
Clean the rocker panel moulding LH surface:
1. When reusing the rocker panel moulding LH, remove remaining double-sided tape from the rocker panel moulding LH.
2. Using a heat light, heat the rocker panel moulding LH surface.
| Part | Temperature |
|---|---|
| Rocker Panel Moulding LH | 20 to 30°C (68 to 86°F) |
| Rocker Panel Moulding Pad | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the rocker panel moulding LH excessively.
3. Remove any remaining double-sided tape from the rocker panel moulding LH and wipe off any tape adhesive residue with cleaner.
4. Clean the installation area surface.
Installing the rocker panel moulding pad with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Also, clean a new rocker panel moulding LH surface.
Using a heat light, heat the rocker panel moulding LH and a new rocker panel moulding pad.
Do not heat the rocker panel moulding LH and rocker panel moulding pad excessively.
Install the 2 rocker panel moulding pads in the position shown in the illustration.
The application strength of the rocker panel moulding pad will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the rocker panel moulding LH.
75897B
3.INSTALL NO. 3 MOULDING TAPE
| *1 | No. 4 Rocker Panel Moulding Protector | *2 | Rocker Panel Moulding Cover LH |
| *a | Mark-off Line | - | - |
|
Installation Area | - | - |
Clean the installation area surface.
Using a heat light, heat the installation area and a new No. 3 moulding tape.
| Part | Temperature |
|---|---|
| No. 4 Rocker Panel Moulding Protector | 20 to 30°C (68 to 86°F) |
| Rocker Panel Moulding Cover LH | 20 to 30°C (68 to 86°F) |
| No. 3 Moulding Tape | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the installation area and No. 3 moulding tape excessively.
Install the 3 No. 3 moulding tapes in the position shown in the illustration.
The application strength of the No. 3 moulding tape will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the installation area.
76926F
4.INSTALL SIDE MUDGUARD PROTECTOR LH
| *a | Mark-off Line | - | - |
|
Installation Area | - | - |
Clean the rocker panel moulding LH surface:
1. When reusing the rocker panel moulding LH, remove remaining double-sided tape from the rocker panel moulding LH.
2. Using a heat light, heat the rocker panel moulding LH surface.
| Part | Temperature |
|---|---|
| Rocker Panel Moulding LH | 20 to 30°C (68 to 86°F) |
| Side Moulding Protector LH | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the rocker panel moulding LH excessively.
3. Remove any remaining double-sided tape from the rocker panel moulding LH and wipe off any tape adhesive residue with cleaner.
4. Clean the installation area surface.
Installing the side moulding protector LH with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Also, clean a new rocker panel moulding LH surface.
Using a heat light, heat the rocker panel moulding LH and a new side moulding protector LH.
Do not heat the rocker panel moulding LH and side moulding protector LH excessively.
Install the side moulding protector LH in the position shown in the illustration.
The application strength of the side moulding protector LH will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the rocker panel moulding LH.
75864B
5.INSTALL NO. 4 ROCKER PANEL MOULDING PROTECTOR
| *a | Mark-off Line | - | - |
|
Installation Area | - | - |
Clean the rocker panel moulding LH surface:
1. When reusing the rocker panel moulding LH, remove remaining double-sided tape from the rocker panel moulding LH.
2. Using a heat light, heat the rocker panel moulding LH surface.
| Part | Temperature |
|---|---|
| Rocker Panel Moulding LH | 20 to 30°C (68 to 86°F) |
| No. 4 Rocker Panel Moulding Protector | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the rocker panel moulding LH excessively.
3. Remove any remaining double-sided tape from the rocker panel moulding LH and wipe off any tape adhesive residue with cleaner.
4. Clean the installation area surface.
Installing the No. 4 rocker panel moulding protector with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Also, clean a new rocker panel moulding LH surface.
Using a heat light, heat the rocker panel moulding LH and a new No. 4 rocker panel moulding protector.
Do not heat the rocker panel moulding LH and No. 4 rocker panel moulding protector excessively.
Install the No. 4 rocker panel moulding protector in the position shown in the illustration.
The application strength of the No. 4 rocker panel moulding protector will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the rocker panel moulding LH.
75858A
6.INSTALL ROCKER PANEL MOULDING COVER LH
| *a | Mark-off Line | - | - |
|
Installation Area | - | - |
Clean the rocker panel moulding LH surface:
1. When reusing the rocker panel moulding LH, remove remaining double-sided tape from the rocker panel moulding LH.
2. Using a heat light, heat the rocker panel moulding LH surface.
| Part | Temperature |
|---|---|
| Rocker Panel Moulding LH | 20 to 30°C (68 to 86°F) |
| Rocker Panel Moulding Cover LH | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the rocker panel moulding LH excessively.
3. Remove any remaining double-sided tape from the rocker panel moulding LH and wipe off any tape adhesive residue with cleaner.
4. Clean the installation area surface.
Installing the rocker panel moulding cover LH with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Also, clean a new rocker panel moulding LH surface.
Using a heat light, heat the rocker panel moulding LH and a new rocker panel moulding cover LH.
Do not heat the rocker panel moulding LH and rocker panel moulding cover LH excessively.
Install the rocker panel moulding cover LH in the position shown in the illustration.
The application strength of the rocker panel moulding cover LH will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the rocker panel moulding LH.