If no air is discharged even when the air conditioning control assembly is operated, the following causes are possible.
| Symptom | Factor |
|---|---|
| Blower does not operate at all
(No air comes out) |
·
Blower with fan motor sub-assembly malfunction (battery and ground circuit) ·
Control signal malfunction between air conditioning assembly and blower with fan motor sub-assembly ·
Blower with fan motor sub-assembly malfunction ·
Air conditioning amplifier assembly malfunction ·
Warm-up Control ·
FC stack outlet coolant temperature |
Operate the manual mode to check that the blower with fan motor sub-assembly is operated normally.
Blower with fan motor sub-assembly is operated normally with manual mode.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) | FC stack outlet coolant temperature | -40°C (-40°F) to 215.9 °C (421 °F) | 50 to 85 °C (122 to 185 °F): After warming up | - |
| Tester Display |
|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) |
The temperature at the time of the warming up is satisfied the normal condition.
| Proceed to |
|---|
| OK |
| NG |
OK
NG