HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Blower Motor does not Operate  


DESCRIPTION

If no air is discharged even when the air conditioning control assembly is operated, the following causes are possible.

Symptom Factor
Blower does not operate at all

(No air comes out)


·

Blower with fan motor sub-assembly malfunction (battery and ground circuit)

·

Control signal malfunction between air conditioning assembly and blower with fan motor sub-assembly

·

Blower with fan motor sub-assembly malfunction

·

Air conditioning amplifier assembly malfunction

·

Warm-up Control

·

FC stack outlet coolant temperature



PROCEDURE

1.CHECK AIR CONDITIONING SYSTEM (MANUAL MODE)
a.

Operate the manual mode to check that the blower with fan motor sub-assembly is operated normally.

OK:

Blower with fan motor sub-assembly is operated normally with manual mode.



Result:
Proceed to
OK
NG



OK

2.READ VALUE USING GTS (COOLANT TEMPERATURE)

NG

2.READ VALUE USING GTS (COOLANT TEMPERATURE)
a.

Read the Data List according to the display on the GTS.

Powertrain > EV > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
FC Stack Outlet Coolant Temperature (Filtered Value) FC stack outlet coolant temperature -40°C (-40°F) to 215.9 °C (421 °F) 50 to 85 °C (122 to 185 °F): After warming up -
Powertrain > EV > Data List
Tester Display
FC Stack Outlet Coolant Temperature (Filtered Value)
50003 397 998
OK:

The temperature at the time of the warming up is satisfied the normal condition.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG