The EV control ECU detects serial communication malfunctions with the FC hydrogen pump inverter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D8387 | Lost Communication with Hydrogen Pump Inverter Missing Message | When hydrogen pump LIN communication control is ON, there is a communication stop between the EV control ECU and hydrogen pump inverter for 1.5 seconds or more continuously.
(1 trip detection logic) |
·
FC hydrogen pump inverter assembly ·
EV control ECU ·
IGCT NO. 2 relay ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | ○ | ○ | ○ | ○ | - |
By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1D8387 | - |
Inspect the fuses of circuits related to this system before performing the following procedure.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Working Mode" is Startup or Working. Then, wait for 2 minutes or more.
Pre-procedure1
Disconnect the FC hydrogen pump inverter assembly connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B3)Location & Routingewd_type=routing;type=c;code=B3 Click Connector(B3)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B3;pinno=1 |
||
| B3-1 (H+B1) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the FC hydrogen pump inverter assembly connector.
OK
NG
Pre-procedure1
Disconnect the FC hydrogen pump inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B3)Location & Routingewd_type=routing;type=c;code=B3 Click Connector(B3)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B3;pinno=2 |
||
| B3-2 (HGND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC hydrogen pump inverter assembly connector.
OK
NG
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the FC hydrogen pump inverter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A15,B3)Location & Routingewd_type=routing;type=c,c;code=A15,B3 Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A15;pinno=9 Click Connector(B3)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B3;pinno=3 |
||
| A15-9 (LIN1) - B3-3 (HLIN) | Always | Below 1 Ω |
| A15-9 (LIN1) or B3-3 (HLIN) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC hydrogen pump inverter assembly connector.
Reconnect the EV control ECU connector.
OK
NG
Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Startup or Working. Then, wait for 2 minutes or more.
| Tester Display |
|---|
| FC Work Mode |
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1D8387 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
Disconnect the FC hydrogen pump inverter assembly connector.
Remove the IGCT NO. 2 relay from the No. 1 front compartment relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B3)Location & Routingewd_type=routing;type=c;code=B3 Click Connector(B3)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B3;pinno=1 |
||
| B3-1 (H+B1) - 5 (IGCT NO. 2 relay holder) | Always | Below 1 Ω |
| B3-1 (H+B1) or 5 (IGCT NO. 2 relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reinstall the IGCT NO. 2 relay.
Reconnect the FC hydrogen pump inverter assembly connector.
OK
NG