The hydrogen pump motor temperature sensor monitors temperatures of the hydrogen recirculation pump assembly. The hydrogen pump motor temperature sensor has a built-in thermistor with a resistance that varies according to the temperature of the hydrogen pump motor. When the hydrogen pump motor temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the EV control ECU as voltage changes.
The hydrogen pump motor temperature sensor is connected to the EV control ECU, and a power voltage of 5 V is supplied from the HTM terminal of the EV control ECU to the sensor via resistor R. Since resistor R and the sensor are connected in series, resistance varies as a hydrogen pump motor temperature changes, and potential of the HTM terminal also varies.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D8511 | Hydrogen Pump Motor Temperature Sensor Circuit Short to Ground | If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the hydrogen pump motor temperature sensor circuit remains at less than 0.05 V for more than 3 seconds.
(1 trip detection logic) |
·
Hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| P1D8515 | Hydrogen Pump Motor Temperature Sensor Circuit Short to Battery or Open | If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the hydrogen pump motor temperature sensor circuit remains at more than 4.95 V for more than 3 seconds.
(1 trip detection logic) |
·
Hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1D8511 | ·
Hydrogen Pump Motor Temperature Sensor Voltage ·
Hydrogen Pump Motor Temperature (Filtered Value) |
| P1D8515 |
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 3 seconds or more.
Read the value displayed on the GTS.
| Tester Display |
|---|
| Hydrogen Pump Motor Temperature Sensor Voltage |
| Result | Proceed to |
|---|---|
| The value of Hydrogen Pump Motor Temperature Sensor Voltage is more than 4.95 V | A |
| The value of Hydrogen Pump Motor Temperature Sensor Voltage is less than 0.05 V | B |
If there is an open circuit, the GTS indicates more than 4.95 V.
If there is a short circuit, the GTS indicates less than 0.05 V.
A
B
Pre-procedure1
Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Connect terminals 2 (THW) and 1 (E2) of the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector on the wire harness side.
Procedure1
| *1 | Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor) |
| *2 | EV Control ECU |
| *a | Front view of wire harness connector
(to Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor)) |
Read the value displayed on the GTS.
| Tester Display |
|---|
| Hydrogen Pump Motor Temperature Sensor Voltage |
| Result | Proceed to |
|---|---|
| The value of Hydrogen Pump Motor Temperature Sensor Voltage is less than 0.05 V | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A15,B25)Location & Routingewd_type=routing;type=c,c;code=A15,B25 Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A15;pinno=26,34 Click Connector(B25)Engine Compartment>No. 2 Stack Wire>Hydrogen Recirculation Pump Assemblyewd_type=component;type=c;code=B25;pinno=2,1 |
||
| A15-26 (HTM) - B25-2 (THW) | Always | Below 1 Ω |
| A15-34 (GHTM) - B25-1 (E2) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Procedure1
| *1 | Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor) |
| *2 | EV Control ECU |
Read the value displayed on the GTS.
| Tester Display |
|---|
| Hydrogen Pump Motor Temperature Sensor Voltage |
| Result | Proceed to |
|---|---|
| The value of Hydrogen Pump Motor Temperature Sensor Voltage is more than 4.95 V | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A15,B25)Location & Routingewd_type=routing;type=c,c;code=A15,B25 Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A15;pinno=26 Click Connector(B25)Engine Compartment>No. 2 Stack Wire>Hydrogen Recirculation Pump Assemblyewd_type=component;type=c;code=B25;pinno=2 |
||
| A15-26 (HTM) or B25-2 (THW) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.
Reconnect the EV control ECU connector.
OK
NG