Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1D8511  Hydrogen Pump Motor Temperature Sensor Circuit Short to Ground  P1D8515  Hydrogen Pump Motor Temperature Sensor Circuit Short to Battery or Open  


DESCRIPTION

The hydrogen pump motor temperature sensor monitors temperatures of the hydrogen recirculation pump assembly. The hydrogen pump motor temperature sensor has a built-in thermistor with a resistance that varies according to the temperature of the hydrogen pump motor. When the hydrogen pump motor temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the EV control ECU as voltage changes.

The hydrogen pump motor temperature sensor is connected to the EV control ECU, and a power voltage of 5 V is supplied from the HTM terminal of the EV control ECU to the sensor via resistor R. Since resistor R and the sensor are connected in series, resistance varies as a hydrogen pump motor temperature changes, and potential of the HTM terminal also varies.

A342606E04
0.104,0.229 1.125,0.458 1.021,0.229 10 false Reference: 2.604,0.365 3.396,0.615 0.792,0.25 10 false Resistance 3.792,3.188 4.583,3.438 0.792,0.25 10 false Temperature 2.823,0.615 3.615,0.865 0.792,0.25 10 false (kΩ) 2.573,0.802 3.365,1.052 0.792,0.25 10 false 10000 2.646,1.146 3.438,1.396 0.792,0.25 10 false 1000 2.719,1.5 3.51,1.75 0.792,0.25 10 false 100 2.792,1.854 3.583,2.104 0.792,0.25 10 false 10 2.865,2.208 3.656,2.458 0.792,0.25 10 false 1 2.74,2.563 3.531,2.813 0.792,0.25 10 false 0.1 2.917,2.708 3.708,2.958 0.792,0.25 10 false -50 2.927,2.917 3.719,3.167 0.792,0.25 10 false -80 3.552,2.708 4.344,2.958 0.792,0.25 10 false 0 3.51,2.896 3.781,3.146 0.271,0.25 10 false 32 4.104,2.708 4.375,2.958 0.271,0.25 10 false 50 4.656,2.719 4.979,2.938 0.323,0.219 10 false 100 5.26,2.719 5.583,2.938 0.323,0.219 10 false 150 4.063,2.896 4.354,3.135 0.292,0.24 10 false 122 4.667,2.896 4.958,3.135 0.292,0.24 10 false 212 5.271,2.896 5.563,3.135 0.292,0.24 10 false 302 5.656,2.698 5.948,2.938 0.292,0.24 10 false (°C) 5.667,2.896 5.958,3.135 0.292,0.24 10 false (°F) 0.094,0.49 2.281,0.865 2.188,0.375 10 false Hydrogen Pump Motor Temperature Sensor Characteristic Graph

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1D8511 Hydrogen Pump Motor Temperature Sensor Circuit Short to Ground If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the hydrogen pump motor temperature sensor circuit remains at less than 0.05 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor)

·

EV control ECU

·

Wire harness or connector


Master Warning: Comes on EV A
P1D8515 Hydrogen Pump Motor Temperature Sensor Circuit Short to Battery or Open If the +B voltage is not low when the ignition switch is turned to ON, the output voltage of the hydrogen pump motor temperature sensor circuit remains at more than 4.95 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor)

·

EV control ECU

·

Wire harness or connector


Master Warning: Comes on EV A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List
"FC Work Mode"
Stop Startup Working Finishing
Data List
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ -

HINT:

By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.


Related Data List
DTC No. Data List
P1D8511
·

Hydrogen Pump Motor Temperature Sensor Voltage

·

Hydrogen Pump Motor Temperature (Filtered Value)


P1D8515

WIRING DIAGRAM

A342605E04
0.927,2.052 2.323,2.406 1.396,0.354 10 false Hydrogen Pump Motor Temperature Sensor 2.552,1.156 3.01,1.354 0.458,0.198 10 false THW 2.667,1.646 3.125,1.844 0.458,0.198 10 false E2 0.396,2.948 0.854,3.146 0.458,0.198 10 false B25 0.406,3.125 3.031,3.479 2.625,0.354 10 false Hydrogen Recirculation Pump Assembly 5.031,2.979 5.49,3.177 0.458,0.198 10 false A15 5.031,3.135 6.427,3.49 1.396,0.354 10 false EV Control ECU 2.969,1.156 3.427,1.354 0.458,0.198 10 false 2 2.969,1.635 3.427,1.833 0.458,0.198 10 false 1 4.323,1.167 4.781,1.365 0.458,0.198 10 false 26 4.323,1.656 4.781,1.854 0.458,0.198 10 false 34 4.573,1.167 5.031,1.365 0.458,0.198 10 false HTM 4.573,1.656 5.031,1.854 0.458,0.198 10 false GHTM 5.76,0.75 6.219,0.948 0.458,0.198 10 false 5 V

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON and wait for 3 seconds or more.



PROCEDURE

1.READ VALUE USING GTS (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR VOLTAGE)
a.

Read the value displayed on the GTS.

Powertrain > EV > Data List
Tester Display
Hydrogen Pump Motor Temperature Sensor Voltage
50003 397 729
Result:
Result Proceed to
The value of Hydrogen Pump Motor Temperature Sensor Voltage is more than 4.95 V A
The value of Hydrogen Pump Motor Temperature Sensor Voltage is less than 0.05 V B


HINT:
·

If there is an open circuit, the GTS indicates more than 4.95 V.

·

If there is a short circuit, the GTS indicates less than 0.05 V.





A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

4.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

Pre-procedure1

a.
A476970

Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


b.

Connect terminals 2 (THW) and 1 (E2) of the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector on the wire harness side.


Procedure1

a.
A408370C04
0.698,3.396 1.094,3.708 0.396,0.313 1.156,4.188 1.552,3.646 true 2.198,4.156 1.917,3.625 true 0.604,0.146 0.917,0.302 0.313,0.156 10 false *1 2.781,0.104 3.094,0.26 0.313,0.156 10 false *2 0.813,2.688 1.125,2.844 0.313,0.156 10 false *a 0.781,3.458 1.208,3.677 0.427,0.219 10 false B25 2.177,4.229 2.604,4.448 0.427,0.219 10 false THW 0.979,4.24 1.406,4.458 0.427,0.219 10 false E2
*1 Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor)
*2 EV Control ECU
*a Front view of wire harness connector
(to Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor))


Read the value displayed on the GTS.

Powertrain > EV > Data List
Tester Display
Hydrogen Pump Motor Temperature Sensor Voltage
50003 397 729

Result:
Result Proceed to
The value of Hydrogen Pump Motor Temperature Sensor Voltage is less than 0.05 V A
None of the above conditions are met B


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.



A

REPLACE HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR)

B

3.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR))
3.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.

Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(A15,B25)Location & Routing

Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(B25)Engine Compartment>No. 2 Stack Wire>Hydrogen Recirculation Pump Assembly

A15-26 (HTM) - B25-2 (THW) Always Below 1 Ω
A15-34 (GHTM) - B25-1 (E2) Always Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


b.

Reconnect the EV control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)

Pre-procedure1

a.
A476970

Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


Procedure1

a.
A335356C04
0.719,0.427 1.031,0.625 0.313,0.198 10 false *1 2.604,0.281 2.917,0.479 0.313,0.198 10 false *2
*1 Hydrogen Recirculation Pump Assembly (Hydrogen Pump Motor Temperature Sensor)
*2 EV Control ECU


Read the value displayed on the GTS.

Powertrain > EV > Data List
Tester Display
Hydrogen Pump Motor Temperature Sensor Voltage
50003 397 729

Result:
Result Proceed to
The value of Hydrogen Pump Motor Temperature Sensor Voltage is more than 4.95 V A
None of the above conditions are met B


Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.



A

REPLACE HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR)

B

5.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR))
5.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN RECIRCULATION PUMP ASSEMBLY (HYDROGEN PUMP MOTOR TEMPERATURE SENSOR))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.

Disconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(A15,B25)Location & Routing

Click Connector(A15)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(B25)Engine Compartment>No. 2 Stack Wire>Hydrogen Recirculation Pump Assembly

A15-26 (HTM) or B25-2 (THW) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen recirculation pump assembly (hydrogen pump motor temperature sensor) connector.


b.

Reconnect the EV control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR