Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1DB011  High-Range Hydrogen Pressure Sensor Circuit Short to Ground  P1DB015  High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open  


DESCRIPTION

The hydrogen tank pressure sensor (for outlet side) is provided on the hydrogen tank tube joint assembly (for outlet side), and it detects and converts pressure of the hydrogen supply system (high-range pressure area) into a voltage values.

The FC control ECU checks for leaks in the hydrogen supply system (high-range pressure area) when the FC system is activated, and monitors pressure in the hydrogen supply system while the FC is in operation, though use of hydrogen tank pressure sensor (for outlet side) values.

A479994E03
0.073,0.052 1.688,0.76 1.615,0.708 10 false Reference: Hydrogen Tank Pressure Sensor (for outlet side) Characteristic Graph 1.896,0 2.792,0.24 0.896,0.24 10 false Voltage (V) 2.094,0.365 2.646,0.594 0.552,0.229 10 false 4.4 2.094,0.625 2.646,0.854 0.552,0.229 10 false 3.6 2.083,1.052 2.635,1.281 0.552,0.229 10 false 2.2 2.083,1.521 2.635,1.75 0.552,0.229 10 false 0.8 2.604,1.885 2.802,2.115 0.198,0.229 10 false 0 3.25,1.885 3.448,2.115 0.198,0.229 10 false 35 3.906,1.885 4.104,2.115 0.198,0.229 10 false 70 4.333,1.885 4.531,2.115 0.198,0.229 10 false 90 4.906,1.76 5.26,1.979 0.354,0.219 10 false MPa 4.896,2.229 5.25,2.448 0.354,0.219 10 false psi 3.167,2.354 3.542,2.573 0.375,0.219 10 false 5075 3.813,2.354 4.219,2.573 0.406,0.219 10 false 10150 4.271,2.354 4.729,2.573 0.458,0.219 10 false 13050 2.594,2.333 2.792,2.563 0.198,0.229 10 false 0

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1DB011 High-Range Hydrogen Pressure Sensor Circuit Short to Ground If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen tank pressure sensor (for outlet side) circuit remains at less than 0.15 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen tank pressure sensor (for outlet side)

·

FC control ECU

·

Wire harness or connector


Master Warning: Comes on FC A
P1DB015 High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen tank pressure sensor (for outlet side) circuit remains at more than 4.85V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen tank pressure sensor (for outlet side)

·

FC control ECU

·

Wire harness or connector


Master Warning: Comes on FC A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List (EV)
"FC Work Mode"
Stop Startup Working Finishing
Data List (EV)
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ -

Related Data List
DTC No. Data List
P1DB011 High-Range Hydrogen Pressure Sensor Voltage
P1DB015

HINT:

If DTCs are found, read the "High-Range Hydrogen Pressure Sensor Voltage" in the Data List on a GTS.


High-Range Hydrogen Pressure Sensor Voltage Malfunction
Less than 0.15 V
·

Open in VHPT (5 V power supply) circuit

·

Short in HPT circuit to ground

·

Short in HPT circuit to GHPT (GND) circuit

·

Short in VHPT circuit to ground


Higher than 4.85 V
·

Short in VHPT circuit to HPT circuit

·

Open in HPT circuit

·

Open in GHPT (GND) circuit



HINT:

It is suspected that malfunctions, or open/short circuits have occurred in the Hydrogen tank pressure sensor (for outlet side).


WIRING DIAGRAM

A480009E03
0.25,1.323 0.708,1.521 0.458,0.198 10 false B10 0.25,1.479 2.76,1.75 2.51,0.271 10 false Hydrogen Primary Pressure Sensor 1.25,0.531 1.708,0.729 0.458,0.198 10 false VHPM 1.344,0.823 1.802,1.021 0.458,0.198 10 false HPM 1.24,1.115 1.698,1.313 0.458,0.198 10 false GHPM 1.771,0.375 2.229,0.573 0.458,0.198 10 false 3 1.771,0.677 2.229,0.885 0.458,0.208 10 false 2 1.771,1.01 2.229,1.219 0.458,0.208 10 false 1 4.281,0.385 4.604,0.573 0.323,0.188 10 false 114 4.281,0.708 4.604,0.896 0.323,0.188 10 false 112 4.292,1.021 4.615,1.208 0.323,0.188 10 false 113 4.365,1.333 4.688,1.521 0.323,0.188 10 false 89 4.667,0.396 5.125,0.594 0.458,0.198 10 false VHPM 4.698,0.708 5.156,0.906 0.458,0.198 10 false HPM 4.677,1.01 5.135,1.208 0.458,0.198 10 false GHPM 4.677,1.323 5.135,1.521 0.458,0.198 10 false DRN3 5.927,0.271 6.25,0.458 0.323,0.188 10 false 5 V 6.271,0.448 6.594,0.635 0.323,0.188 10 false 5 V 6.292,2.156 6.615,2.344 0.323,0.188 10 false 5 V 6.24,3.833 6.563,4.021 0.323,0.188 10 false 5 V 0.219,3.021 0.677,3.219 0.458,0.198 10 false B11 0.208,3.188 2.75,3.417 2.542,0.229 10 false Hydrogen Secondary Pressure Sensor 1.271,2.208 1.729,2.406 0.458,0.198 10 false VHPL 1.354,2.531 1.813,2.729 0.458,0.198 10 false HPL 1.271,2.813 1.729,3.01 0.458,0.198 10 false GHPL 1.802,2.083 2.26,2.281 0.458,0.198 10 false 3 1.802,2.375 2.26,2.583 0.458,0.208 10 false 2 1.792,2.698 2.25,2.906 0.458,0.208 10 false 1 4.698,2.104 5.156,2.302 0.458,0.198 10 false VHPL 4.719,2.396 5.177,2.594 0.458,0.198 10 false HPL 4.698,2.698 5.156,2.896 0.458,0.198 10 false GHPL 4.698,2.979 5.156,3.177 0.458,0.198 10 false DRN1 4.365,2.083 4.688,2.271 0.323,0.188 10 false 68 4.365,2.385 4.688,2.573 0.323,0.188 10 false 67 4.354,2.688 4.677,2.875 0.323,0.188 10 false 66 4.354,2.938 4.677,3.125 0.323,0.188 10 false 90 5.115,5.313 5.573,5.51 0.458,0.198 10 false B1 0.115,4.885 3.281,5.135 3.167,0.25 10 false Hydrogen Tank Pressure Sensor (for Outlet Side) 0.5,5.469 2.042,5.688 1.542,0.219 10 false *: Shield Ground 1.281,3.917 1.74,4.115 0.458,0.198 10 false VHPT 1.375,4.198 1.833,4.396 0.458,0.198 10 false HPT 1.271,4.5 1.729,4.698 0.458,0.198 10 false GHPT 1.813,3.771 2.271,3.969 0.458,0.198 10 false 3 1.813,4.073 2.271,4.281 0.458,0.208 10 false 2 1.823,4.385 2.281,4.594 0.458,0.208 10 false 1 4.677,3.792 5.135,3.99 0.458,0.198 10 false VHPT 4.688,4.115 5.146,4.313 0.458,0.198 10 false HPT 4.656,4.406 5.115,4.604 0.458,0.198 10 false GHPT 4.667,4.677 5.125,4.875 0.458,0.198 10 false DRN2 4.302,3.781 4.625,3.969 0.323,0.188 10 false 115 4.313,4.094 4.635,4.281 0.323,0.188 10 false 117 4.302,4.406 4.625,4.594 0.323,0.188 10 false 116 4.354,4.677 4.677,4.865 0.323,0.188 10 false 95 5.125,5.479 6.875,5.75 1.75,0.271 10 false FC Control ECU 3.646,1.583 4.104,1.792 0.458,0.208 10 false * 3.646,3.24 4.104,3.448 0.458,0.208 10 false * 3.635,4.938 4.094,5.146 0.458,0.208 10 false * 0.115,4.74 0.573,4.938 0.458,0.198 10 false G7

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON and wait for 3 seconds or more.



PROCEDURE

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.
A476959

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G7)Location & Routing

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

G7-3 (VHPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V
G7-2 (HPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.



OK

2.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

NG

6.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))
2.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,G7)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

B1-117 (HPT) - G7-2 (HPT) Always Below 1 Ω
B1-116 (GHPT) - G7-1 (GHPT) Always Below 1 Ω
B1-115 (VHPT) - G7-3 (VHPT) Always Below 1 Ω
B1-117 (HPT) or G7-2 (HPT) - Body ground and other terminals Always 10 kΩ or higher
B1-115 (VHPT) or G7-3 (VHPT) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.

Reconnect the FC control ECU connector.



OK

3.REPLACE HYDROGEN TANK TUBE JOINT ASSEMBLY (HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE HYDROGEN TANK TUBE JOINT ASSEMBLY (HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

NEXT

4.CLEAR DTC
4.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > FC > Clear DTCs
50002 490
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

5.CHECK DTC OUTPUT
5.CHECK DTC OUTPUT

Pre-procedure1

a.

Turn the ignition switch to ON and wait for 3 seconds or more.


Procedure1

a.

Check for DTCs.

Powertrain > FC > Trouble Codes
50001 490
Result:
Result Proceed to
P1DB011 or P1DB015 is output A
DTCs are not output B



Post-procedure1

a.

Turn the ignition switch off.



A

B

END

6.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.
A476941

Disconnect the hydrogen secondary pressure sensor connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G7)Location & Routing

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

G7-3 (VHPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V
G7-2 (HPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen secondary pressure sensor connector.


c.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.



OK

REPLACE HYDROGEN SECONDARY PRESSURE SENSOR

NG

7.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))
7.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.
A478999

Disconnect the hydrogen primary pressure sensor connector.


c.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G7)Location & Routing

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

G7-3 (VHPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V
G7-2 (HPT) - G7-1 (GHPT) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen primary pressure sensor connector.


c.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.



OK

REPLACE HYDROGEN PRIMARY PRESSURE SENSOR

NG

8.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))
8.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN TANK PRESSURE SENSOR (FOR OUTLET SIDE))

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen tank pressure sensor (for outlet side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,G7)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(G7)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Pressure Sensor

B1-117 (HPT) - G7-2 (HPT) Always Below 1 Ω
B1-116 (GHPT) - G7-1 (GHPT) Always Below 1 Ω
B1-115 (VHPT) - G7-3 (VHPT) Always Below 1 Ω
B1-117 (HPT) or G7-2 (HPT) - Body ground and other terminals Always 10 kΩ or higher
B1-115 (VHPT) or G7-3 (VHPT) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen tank pressure sensor (for outlet side) connector.


b.

Reconnect the FC control ECU connector.



OK

9.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN SECONDARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen secondary pressure sensor connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,B11)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensor

B1-68 (VHPL) - B11-3 (VHPL) Always Below 1 Ω
B1-68 (VHPL) or B11-3 (VHPL) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen secondary pressure sensor connector.


b.

Reconnect the FC control ECU connector.



OK

10.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN PRIMARY PRESSURE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - HYDROGEN PRIMARY PRESSURE SENSOR)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Disconnect the hydrogen primary pressure sensor connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B1,B10)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

Click Connector(B10)Engine Compartment>No. 2 Stack Wire>Hydrogen Primary Pressure Sensor

B1-114 (VHPM) - B10-3 (VHPM) Always Below 1 Ω
B1-114 (VHPM) or B10-3 (VHPM) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen primary pressure sensor connector.


b.

Reconnect the FC control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR