RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466410 HYDROGEN PRESSURE SENSOR A

FC CONTROL  HYDROGEN PRESSURE SENSOR  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
A484122N02
0.448,0.365 4.396,2.677 3.948,2.313 4.448,1.656 6.917,3.635 2.469,1.979 2.521,1.563 2.844,1.063 2.844,1.063 3.031,1.063 true 1.948,1.375 1.875,1.688 1.875,1.688 1.646,1.688 true 3.042,1.99 2.781,2.396 2.781,2.396 2.552,2.396 true 6.302,0.26 6.74,0.26 true 5,3.052 5.635,3.052 true 4.917,2.542 5.24,2.042 5.24,2.042 5.427,2.042 true 4.531,1.75 4.906,2.031 0.375,0.281 12 false *A 0.542,0.438 0.917,0.719 0.375,0.281 12 false *B 1.458,1.542 1.823,1.906 0.365,0.365 18 false 5 4.792,2.927 5.167,3.292 0.375,0.365 18 false 4 5.833,0.135 6.396,0.49 0.563,0.354 18 false 1, 2 2.385,2.271 2.76,2.635 0.375,0.365 18 false 3 5.5,1.938 5.875,2.219 0.375,0.281 10 false ● 3.094,0.958 3.469,1.24 0.375,0.281 10 false ●

Procedure Part Name Code
Z101186

Z101188

Z101187

1 CAUTIONS FOR COMPRESSED HYDROGEN GAS - - - (Click here)
2 PRESSURE RELEASE OPERATION (for Low Pressure and Medium Pressure) - - - (Click here)
3 HYDROGEN SUPPLY PRESSURE REGULATOR ASSEMBLY 23A30 - - -
4 HYDROGEN PRIMARY PRESSURE SENSOR G4132 (Click here) - -
5 HYDROGEN SECONDARY PRESSURE SENSOR G4133 (Click here) - -

*A for Medium Pressure *B for Low Pressure
● Non-reusable part - -

CAUTION / NOTICE / HINT

PROCEDURE

Hide 1. CAUTIONS FOR COMPRESSED HYDROGEN GAS

Hide 2. PRESSURE RELEASE OPERATION (for Low Pressure and Medium Pressure)

Hide 23A30 3.REMOVE HYDROGEN SUPPLY PRESSURE REGULATOR ASSEMBLY (for Low Pressure)

Hide G4132 4.REMOVE HYDROGEN PRIMARY PRESSURE SENSOR (for Medium Pressure)

a.
A480946N01
0.125,0.146 0.292,0.427 0.167,0.281 18 true i 3.802,0.208 4,0.531 0.198,0.323 18 true ii 0.521,2.042 0.729,2.365 0.208,0.323 18 true iii 3.833,2.063 4.063,2.406 0.229,0.344 18 true iv

i.

Detach the clamp and disconnect the connector.


ii.

Using a 24 mm deep socket wrench, remove the hydrogen primary sensor.


iii.

Protect the openings of the hydrogen supply pressure regulator assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.


iv.

Remove the O-ring from the hydrogen primary pressure sensor.



Hide G4133 5.REMOVE HYDROGEN SECONDARY PRESSURE SENSOR (for Low Pressure)

a.
A475831E01
0.25,0.125 0.531,0.479 0.281,0.354 18 false i 3.125,0.125 3.406,0.479 0.281,0.354 18 false ii 5.406,0.104 5.688,0.458 0.281,0.354 18 false iii

i.

Remove the bolt and hydrogen secondary pressure sensor.


ii.

Protect the openings of the hydrogen supply pressure regulator assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.


iii.

Remove the O-ring from the hydrogen secondary pressure sensor.