1. CAUTIONS FOR COMPRESSED HYDROGEN GAS
2. PRESSURE RELEASE OPERATION (for Low Pressure and Medium Pressure)
23A30
3.REMOVE HYDROGEN SUPPLY PRESSURE REGULATOR ASSEMBLY (for Low Pressure)
G4132
4.REMOVE HYDROGEN PRIMARY PRESSURE SENSOR (for Medium Pressure)
Detach the clamp and disconnect the connector.
Using a 24 mm deep socket wrench, remove the hydrogen primary sensor.
Protect the openings of the hydrogen supply pressure regulator assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.
Remove the O-ring from the hydrogen primary pressure sensor.
G4133
5.REMOVE HYDROGEN SECONDARY PRESSURE SENSOR (for Low Pressure)
Remove the bolt and hydrogen secondary pressure sensor.
Protect the openings of the hydrogen supply pressure regulator assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.
Remove the O-ring from the hydrogen secondary pressure sensor.