One hydrogen detector each is positioned on the upper fuel injector assembly in the front compartment, between the No. 1 hydrogen tank assembly and No. 2 hydrogen tank assembly in the under floor, and in the upper No. 3 hydrogen tank assembly, to detect hydrogen leaks from the vehicle pipe joints and output the hydrogen concentration of these to the EV control ECU.
Concentration detection begins when approximately 5 seconds have elapsed after the ignition switch is turned from off to ON. When a detected concentration is above 2%, a warning light is illuminated to indicate it to the driver, and when it is above 3%, the FC system is forced to shut down.
The sensor actuation circuit has the bridge circuit shown in the illustration below, and the detection and compensation elements are designed to be equal in resistance when they are exposed to air without hydrogen gas. As a result, RS x R1 = RR x R2 is maintained, and the bridge circuit is in equilibrium, causing a sensor output to be 0 V. However, if the detection element is exposed to air that includes hydrogen gas, it burns and the resistance will increase due to the heat, causing the bridge circuit to become unbalanced, as a result, the sensor output will also increase. This sensor output is proportional to the concentration of hydrogen gas.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DCA31 | Hydrogen Detector (Motor Room) No Signal | All of the following conditions are met, and the output frequency of the hydrogen detector (for front compartment side) is less than 0.75 kHz and such a frequency continues for 3 seconds or more:
·
+B voltage is not low ·
2 seconds or more after starting the EV control ECU (1 trip detection logic) |
·
Hydrogen detector (for front compartment side) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
| DTC No. | Data List |
|---|---|
| P1DCA31 | Hydrogen Detector (Motor Room) Frequency |
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 30 seconds or more.
Pre-procedure1
Disconnect the hydrogen detector (for front compartment side) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B20)Location & Routingewd_type=routing;type=c;code=B20 Click Connector(B20)Engine Compartment>No. 2 Stack Wire>Hydrogen Detector (Motor Room)ewd_type=component;type=c;code=B20;pinno=3,4,1 |
||
| B20-3 (VDMR) - B20-4 (GND) | Ignition switch ON | 4.8 to 5.2 V |
| B20-1 (HDMR) - B20-4 (GND) | Ignition switch ON | 4.8 to 5.2 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen detector (for front compartment side) connector.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1DCA31 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the hydrogen detector (for front compartment side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A16,B20)Location & Routingewd_type=routing;type=c,c;code=A16,B20 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=32,31,30 Click Connector(B20)Engine Compartment>No. 2 Stack Wire>Hydrogen Detector (Motor Room)ewd_type=component;type=c;code=B20;pinno=3,1,4 |
||
| A16-32 (VDMR) - B20-3 (VDMR) | Always | Below 1 Ω |
| A16-31 (HDMR) - B20-1 (HDMR) | Always | Below 1 Ω |
| A16-30 (EDMR) - B20-4 (GND) | Always | Below 1 Ω |
| A16-32 (VDMR) or B20-3 (VDMR) - Body ground and other terminals | Always | 10 kΩ or higher |
| A16-31 (HDMR) or B20-1 (HDMR) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen detector (for front compartment side) connector.
Reconnect the EV control ECU connector.
OK
NG