Refer to DTC P1DCA31.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1DCA31
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DD031 | Hydrogen Detector Sensor "A" No Signal | All of the following conditions are met, and the output frequency of the hydrogen detector (for hydrogen tank 1, 2 side) is less than 0.75 kHz and such a frequency continues for 3 seconds or more:
·
+B voltage is not low ·
2 seconds or more after starting the EV control ECU (1 trip detection logic) |
·
Hydrogen detector (for hydrogen tank 1, 2 side) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | ○ | ○ | ○ | ○ | ○ | - |
| DTC No. | Data List |
|---|---|
| P1DD031 | Hydrogen Detector 1 Frequency |
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON and wait for 30 seconds or more.
Pre-procedure1
Disconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G6)Location & Routingewd_type=routing;type=c;code=G6 Click Connector(G6)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (Upper Tank)ewd_type=component;type=c;code=G6;pinno=3,4,1 |
||
| G6-3 (VDTN) - G6-4 (GND) | Ignition switch ON | 4.8 to 5.2 V |
| G6-1 (HDTN) - G6-4 (GND) | Ignition switch ON | 4.8 to 5.2 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>HYDROGEN DETECTOR (for Hydrogen Tank Side)>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1DD031 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G14,G6)Location & Routingewd_type=routing;type=c,c;code=G14,G6 Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECUewd_type=component;type=c;code=G14;pinno=17,27,34 Click Connector(G6)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (Upper Tank)ewd_type=component;type=c;code=G6;pinno=3,1,4 |
||
| G14-17 (VDTN) - G6-3 (VDTN) | Always | Below 1 Ω |
| G14-27 (HDTN) - G6-1 (HDTN) | Always | Below 1 Ω |
| G14-34 (EDTN) - G6-4 (GND) | Always | Below 1 Ω |
| G14-17 (VDTN) or G6-3 (VDTN) - Body ground and other terminals | Always | 10 kΩ or higher |
| G14-27 (HDTN) or G6-1 (HDTN) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the EV control ECU connector.
Disconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A14,G6)Location & Routingewd_type=routing;type=c,c;code=A14,G6 Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A14;pinno=17,27,34 Click Connector(G6)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (Upper Tank)ewd_type=component;type=c;code=G6;pinno=3,1,4 |
||
| A14-17 (VDTN) - G6-3 (VDTN) | Always | Below 1 Ω |
| A14-27 (HDTN) - G6-1 (HDTN) | Always | Below 1 Ω |
| A14-34 (EDTN) - G6-4 (GND) | Always | Below 1 Ω |
| A14-17 (VDTN) or G6-3 (VDTN) - Body ground and other terminals | Always | 10 kΩ or higher |
| A14-27 (HDTN) or G6-1 (HDTN) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen detector (for hydrogen tank 1, 2 side) connector.
Reconnect the EV control ECU connector.
OK
NG