The hydrogen system of the FC system feeds the FC stack with hydrogen, so that the FC stack can generate power. The hydrogen tank temperature sensor calculates a remaining amount of the hydrogen in the tank, and then corrects the calculation value with the temperature inside the tank so that a precise remaining amount of hydrogen can be output to the meter.
The remaining amount of hydrogen is used when the hydrogen tanks are refilled.
If the temperature difference among the 3 tanks has deviated from an estimated difference under specified conditions, there is judged to be a deviation from characteristics in any of the temperature sensors and a DTC is stored.
For the circuit diagram, refer to DTC P1DB01C.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1DB01C
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DE51C | Hydrogen Tank 1 Temperature Sensor Circuit Voltage Out of Range | When the FC system is started several hours after turning the ignition switch off, the temperature sensor values of the No. 1, No. 2 and No. 3 hydrogen tank assemblies are compared, and if the deviation is at or above the threshold, any of the tank temperature sensors is judged to be malfunctioning.
(3 times) |
·
No. 1 hydrogen tank assembly ·
No. 2 hydrogen tank assembly ·
No. 3 hydrogen tank assembly |
Master Warning: Comes on | EV | A |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | ○ | - | - | - | - |
The Hydrogen Tank 1 Temperature (Filtered Value), Hydrogen Tank 2 Temperature (Filtered Value) and Hydrogen Tank 3 Temperature (Filtered Value) in the Data List are useful when troubleshooting.
| DTC No. | Data List |
|---|---|
| P1DE51C | ·
Ambient Temperature ·
Hydrogen Tank 1 Temperature (Filtered Value) ·
Hydrogen Tank 2 Temperature (Filtered Value) ·
Hydrogen Tank 3 Temperature (Filtered Value) |
After filling, a hydrogen tank temperature may increase.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch off and leave the vehicle for at least 8 hours.
Check that a temperature difference between the Hydrogen Tank 1 Temperature (Filtered Value), Hydrogen Tank 2 Temperature (Filtered Value) and Hydrogen Tank 3 Temperature (Filtered Value) is less than 15°C (27°F) (it is almost equal to an ambient temperature at the time).
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch off and leave the vehicle for at least 8 hours.
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| Hydrogen Tank 1 Temperature (Filtered Value) |
| Hydrogen Tank 2 Temperature (Filtered Value) |
| Hydrogen Tank 3 Temperature (Filtered Value) |
Difference between the Hydrogen Tank 1 Temperature (Filtered Value), Hydrogen Tank 2 Temperature (Filtered Value) and Hydrogen Tank 3 Temperature (Filtered Value) is less than 15°C (27°F).
Measure the ambient temperature using a thermometer.
| Result | Proceed to | |
|---|---|---|
| OK | A | |
| NG | Difference between the "Hydrogen Tank 1 Temperature (Filtered Value)" and the ambient temperature is more than 10°C (18°F) | B |
| Difference between the "Hydrogen Tank 2 Temperature (Filtered Value)" and the ambient temperature is more than 10°C (18°F) | C | |
| Difference between the "Hydrogen Tank 3 Temperature (Filtered Value)" and the ambient temperature is more than 10°C (18°F) | D | |
Post-procedure1
Turn the ignition switch off.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C