| *1 | HOSE CLAMP | - | - |
| *1 | NO. 1 HYDROGEN SUPPLY REGULATOR PLUG | *2 | O-RING |
| ● | Non-reusable part |
|
TOYOTA Genuine FC Grease |
| *1 | O-RING | - | - |
| ● | Non-reusable part |
|
TOYOTA Genuine FC Grease |
| *1 | COMPRESSION SPRING | *2 | HARNESS BRACKET |
| *3 | GROMMET | - | - |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 36 | NO. 1 HYDROGEN TANK INFORMATION LABEL | 77A18 | ( )
|
- | - |
| *1 | LABEL COVER FILM | - | - |
| ● | Non-reusable part | - | - |
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the No. 2 hydrogen tank assembly removal/installation are shown below.
When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
| Effect/Inoperative Function When Necessary Procedures are not Performed | Necessary Procedures | Link |
|---|---|---|
| Air conditioning system | After the ignition switch is turned to ON, the servo motor and expansion valve standard position is recognized. | - |
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
| *a | When inside of piping is pressurized |
Do not install or remove any hydrogen system components without first performing depressurization procedures.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | Manual Valve Open |
Do not perform depressurization procedures when the manual valve of the hydrogen tank assembly is open.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
When performing depressurization, do not perform procedures by hand without wearing protective glasses and gloves.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | After depressurization procedures, the high pressure piping union nut that is loosened first. |
After performing depressurization procedures, when first loosening the union nut of the high pressure hydrogen piping, do not loosen the union nut by hand without wearing protective glasses and gloves.
Even when depressurization procedures are performed, the pressurized hydrogen gas inside the high pressure hydrogen piping cannot be completely depressurized, so the highly pressurized hydrogen gas remaining in the high pressure hydrogen piping could blow out, resulting in a serious accident.
| *a | Heavy load exceeding the weight limits or size limits of the engine lifter |
Because the hydrogen tank assembly is extremely heavy, make sure to follow the work procedures described in the repair manual.
If work is not performed according to the procedures described in the repair manual, there is a danger that the engine lifter could drop and components could fall down.
When hoisting up the hydrogen tank assembly, do not hoist it when not properly balanced.
The hydrogen tank assembly could fall, resulting in a serious accident.
When installing or removing a compressed hydrogen gas tank immediately after discharging compressed hydrogen gas, do not touch the tank or piping if there is frost on it.
Touching the tank or piping while there is frost on it could result in burn-like injuries due to frostbite.
When performing the primary leak inspection, do not perform procedures without wearing protective glasses and gloves.
High pressure nitrogen gas could cause a serious accident.
When opening the tank shut valve and applying pressure to SST (hydrogen venting tool), stay away from SST (flexible hose).
If SST (flexible hose) comes off, you could be struck by the loose end of SST (flexible hose), causing a serious accident.
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
Place signs [HIGH PRESSURE GAS WORK IN PROGRESS - DO NOT TOUCH!], etc. to warn other technicians to be cautious. (An example sign is included, so make a copy and use it.)
When performing depressurization, do not open or close any parts of the hydrogen gas piping except for the following:
- Adjustment bolt of the hydrogen tank assembly manual valve
- Tank shut valve of the hydrogen tank assembly
- No. 1 hydrogen supply regulator plug
When installing or removing the hydrogen tank assembly, high pressure hydrogen piping, hydrogen inlet receptacle, hydrogen tank tube joint assembly or hydrogen supply regulator, to prevent strain such as twisting from being applied to the high pressure hydrogen piping.
Even when not removing or installing the high pressure hydrogen piping, be careful not to pull or otherwise apply strain to the high pressure hydrogen piping.
When reusable parts such as the hydrogen tank assembly valve portion, hydrogen inlet receptacle, hydrogen tank tube joint assembly and hydrogen supply regulator have been removed, to protect the seal portions and threaded portions from damage as well as to prevent foreign matter such as dust and metal fragments from entering through openings, cover these areas with protective tape.
Do not use packing tape, or any other tape that will leave residue on parts, as protective tape.
| *a | Protective Tape |
| *b | Seal Portion |
| *c | Threaded Portion |
Protect seal portions and threaded portions as shown in the illustration.
To protect the seal portions and threaded portions from damage or contamination by foreign matter, remove the protective tape immediately before installation.
When reassembling components that have been removed, make sure that there is no foreign matter adhering to the openings.
After installing high pressure hydrogen system components, first perform primary leak inspection with low pressure nitrogen gas, and then perform secondary leak inspection.
| *a | Atmosphere Ventilation Hole Cap |
| *b | Relief Valve |
Do not insert any sharp objects into the relief valve of the hydrogen supply regulator.
Do not remove the atmosphere ventilation hole cap of the hydrogen supply regulator.
When the vehicle is parked with the ignition switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the ignition switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
58404B
2.REMOVE REAR NO. 4 FLOOR BOARD SUB-ASSEMBLY
|
Bolt |
|
Screw |
58403L
3.REMOVE REAR NO. 3 FLOOR BOARD SUB-ASSEMBLY
|
Screw |
|
Nut |
|
Grommet | - | - |
58402K
4.REMOVE NO. 2 FLOOR BOARD SUB-ASSEMBLY
|
Bolt |
|
Nut |
|
Grommet | - | - |
Remove the 3 bolts and nut, detach the 8 clips and loosen the 5 grommets.
Slide the cover and loosen the grommet and remove the No. 2 floor board sub-assembly.
58401M
5.REMOVE NO. 1 FLOOR BOARD SUB-ASSEMBLY
|
Bolt |
|
Nut |
|
Grommet | - | - |
Remove the 3 bolts and nut, detach the 8 clips and loosen the 5 grommets.
Slide the cover and loosen the grommet and remove the No. 2 floor board sub-assembly.
57628E
6.REMOVE REAR FLOOR SIDE MEMBER COVER LH
57627G
7.REMOVE REAR FLOOR SIDE MEMBER COVER RH
58398F
8.REMOVE NO. 1 FLOOR UNDER COVER
|
Screw |
|
Nut |
|
Grommet | - | - |
52383E
9.REMOVE NO. 1 DIFFERENTIAL SUPPORT PROTECTOR
52384C
10.REMOVE NO. 2 DIFFERENTIAL SUPPORT PROTECTOR
53661B
11.REMOVE REAR SUSPENSION BRACE COVER
17DB3
12.REMOVE NO. 3 FC EXHAUST PIPE
13.DISCHARGE COMPRESSED HYDROGEN GAS COMPRESSED HYDROGEN GAS (When replacing the hydrogen tank assembly)
14. PRESSURE RELEASE OPERATION
15.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
77BC0
16.REMOVE HYDROGEN TANK TUBE JOINT ASSEMBLY (for Inlet Side)
77BC0
17.REMOVE HYDROGEN TANK TUBE JOINT ASSEMBLY (for Outlet Side)
G1148
18.REMOVE MOTOR CABLE
82163
19.REMOVE NO. 3 FLOOR WIRE
77286H
20.REMOVE NO. 3 FUEL TUBE CLAMP
77286L
21.REMOVE NO. 5 FUEL TUBE CLAMP
Detach the 3 clamp and disconnect the connector and 2 No. 5 fuel tube clamps from the No. 1 hydrogen tank bracket.
77B0F
22.DISCONNECT NO.3 HYDROGEN SUPPLY TUBE SUB-ASSEMBLY
Remove the bolt and disconnect the No. 3 hydrogen supply tube sub-assembly from the hydrogen supply regulator.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
Remove the 2 O-rings from the No. 3 hydrogen supply tube sub-assembly.
To prevent contamination by foreign matter, cover the connecting portions of the No. 3 hydrogen supply tube sub-assembly with plastic bags.
To prevent contamination by foreign matter, cover the openings of the hydrogen supply regulator with protective tape.
When the hydrogen supply regulator will be replaced with a new one, it is not necessary to protect the openings with protective tape.
77A20
23.REMOVE NO. 2 HYDROGEN TANK ASSEMBLY
| *a | Heavy load exceeding the weight limits or size limits of the engine lifter |
Because the hydrogen tank assembly is extremely heavy, make sure to follow the work procedures described in the repair manual.
If work is not performed according to the procedures described in the repair manual, there is a danger that the engine lifter could drop and components could fall down.
| *a | SST (Hydrogen Tank Stand No. 2) | *b | Belt |
| *c | SST (Support No. 1) | *d | SST (Set Bolt A) |
| *e | SST (Support No. 2) | - | - |
Set SST (hydrogen tank stand No. 2) on the engine lifter and secure it with the belt.
Set SST (hydrogen tank stand No. 2) in the middle of the engine lifter and secure the center portion with the belt.
Remove 2 SST (set bolt A) and SST (support No. 1).
Remove 2 SST (set bolt A) and SST (support No. 2).
| *a | Front side of vehicle | *b | SST (Support Rail No. 1) |
| *c | SST (Support No. 3) | *d | SST (Set Bolt C) |
| *e | SST (Set Bolt B) | *f | Scale surface: 692 mm (27.2 in.) |
| *g | Scale surface: 56 mm (2.20 in.) | *h | Scale surface: 88 mm (3.47 in.) |
| *i | Scale surface: 467 mm (18.4 in.) | *j | Front side of vehicle: 244 mm (9.61 in.)
Rear side of vehicle: 265 mm (10.4 in.) |
Adjust SST (support No. 3), SST (support rail No. 1), and tighten SST (set bolt B), SST (set bolt C).
This is done to align SST (hydrogen tank stand No. 2) with the installation condition of the No. 2 hydrogen tank assembly on the vehicle.
| *a | Protrusion | *b | SST (Support No. 3) |
Operate the engine lifter, and set SST (hydrogen tank stand No. 2) against the No. 2 hydrogen tank assembly.
Align the protrusions of each No. 2 hydrogen tank frame sub-assembly with the holes of SST (support No. 3).
When the gap between the No. 2 hydrogen tank frame sub-assembly and SST (support No. 3) is large, rotate SST (support No. 3) to adjust the height.
Remove the 5 bolts.
Operate the engine lifter and slowly remove the No. 2 hydrogen tank assembly from the vehicle.
Make sure that the No. 2 hydrogen tank assembly does not interfere with the hydrogen tank tube.
Check the body paint near the mounting bolts of the No. 2 hydrogen tank frame sub-assembly, and if the paint is peeled off, apply paint.
G4151
24.REMOVE HYDROGEN DETECTOR
77BA6
26.REMOVE NO. 6 HYDROGEN TANK TUBE
|
|
Detach the clamp and using a 19 mm union nut wrench, loosen the union nut and remove the No. 6 hydrogen tank tube from the No. 2 hydrogen tank assembly.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
To prevent contamination by foreign matter, cover the openings of the No. 2 hydrogen tank assembly with protective tape.
When the No. 2 hydrogen tank assembly will be replaced with a new one, it is not necessary to protect the openings with protective tape.
To prevent contamination by foreign matter, cover the connecting portions of the No. 6 hydrogen tank tube with plastic bags.
77BA3
27.REMOVE NO. 3 HYDROGEN TANK TUBE
|
|
Detach the clamp and using a 19 mm union nut wrench, loosen the union nut and remove the No. 3 hydrogen tank tube from the No. 2 hydrogen tank assembly.
When frost has formed on the hydrogen tank assembly or piping, water droplets may be formed when the frost begins to melt. If water droplets enter the tank or piping, it could result in blockage of the hydrogen piping, so do not allow water droplets to enter the tank or piping.
To prevent contamination by foreign matter, cover the openings of the No. 2 hydrogen tank assembly with protective tape.
When the No. 2 hydrogen tank assembly will be replaced with a new one, it is not necessary to protect the openings with protective tape.
To prevent contamination by foreign matter, cover the connecting portions of the No. 3 hydrogen tank tube with plastic bags.
77286J
28.REMOVE NO. 4 FUEL TUBE CLAMP
77AC0
29.REMOVE HYDROGEN SUPPLY REGULATOR ASSEMBLY
77BB5
30.REMOVE NO. 1 HYDROGEN TANK BRACKET
77B45B
31.REMOVE NO. 2 HYDROGEN TANK SPRING BOLT CUP
Remove the 2 bolts, 2 No. 2 hydrogen tank spring bolt cups and 2 compression springs.
77B0A
32.REMOVE NO. 2 HYDROGEN TANK BAND SUB-ASSEMBLY
77A20
33.REMOVE NO. 2 HYDROGEN TANK ASSEMBLY
| *a | Wheel Chocks | - | - |
Using an engine sling device and belts, remove the No. 2 hydrogen tank assembly from the No. 2 hydrogen tank frame sub-assembly.
When hoisting up the hydrogen tank assembly, do not hoist it when not properly balanced.
The hydrogen tank assembly could fall, resulting in a serious accident.
Place the No. 2 hydrogen tank assembly on wheel chocks or similar.
34.REMOVE NO. 2 HYDROGEN TANK FRAME SUB-ASSEMBLY
Remove the nut and harness bracket.
This procedure is only performed when the harness bracket is being replaced.
Remove the 8 grommets.
This procedure is only performed when the grommet is being replaced.
Remove the No. 2 hydrogen tank frame sub-assembly LH and No. 2 hydrogen tank frame sub-assembly RH.
77B61D
35.REMOVE NO. 3 HYDROGEN TANK FRAME SEAT
|
|
77A18
36.REMOVE NO. 1 HYDROGEN TANK INFORMATION LABEL
|
|
| *1 | Label Cover Film | *2 | No. 1 Hydrogen Tank Information Label |
Using a scraper peel off the No. 1 hydrogen tank information label from the No. 2 hydrogen tank assembly.
Using a solvent and cloth, clean the contact surfaces of the No. 1 hydrogen information label and No. 2 hydrogen tank assembly.