Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1DFA11  Hydrogen Intake Pressure Sensor Circuit Short to Ground  P1DFA15  Hydrogen Intake Pressure Sensor Circuit Short to Battery or Open  


DESCRIPTION

The hydrogen tank pressure sensor (for inlet side) is provided on the hydrogen tank tube joint assembly (for inlet side), and is used to detect pressures in the No. 1, No. 2 and No. 3 hydrogen tank assemblies and convert them into voltage.

The hydrogen fuel control ECU assembly monitors hydrogen pressure when the tanks are filled.

A479994E04
0.094,0.073 1.74,0.76 1.646,0.688 10 false Reference: Hydrogen Tank Pressure Sensor (for inlet side) Characteristic Graph 1.927,0.031 2.823,0.229 0.896,0.198 10 false Voltage (V) 2.094,0.365 2.646,0.594 0.552,0.229 10 false 4.4 2.094,0.625 2.646,0.854 0.552,0.229 10 false 3.6 2.083,1.052 2.635,1.281 0.552,0.229 10 false 2.2 2.083,1.521 2.635,1.75 0.552,0.229 10 false 0.8 2.604,1.885 2.802,2.115 0.198,0.229 10 false 0 3.25,1.885 3.448,2.115 0.198,0.229 10 false 35 3.906,1.885 4.104,2.115 0.198,0.229 10 false 70 4.333,1.885 4.531,2.115 0.198,0.229 10 false 90 4.906,1.76 5.26,1.979 0.354,0.219 10 false MPa 4.896,2.229 5.25,2.448 0.354,0.219 10 false psi 3.167,2.354 3.542,2.573 0.375,0.219 10 false 5075 3.813,2.354 4.26,2.573 0.448,0.219 10 false 10150 4.271,2.354 4.729,2.583 0.458,0.229 10 false 13050 2.594,2.333 2.792,2.563 0.198,0.229 10 false 0

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1DFA11 Hydrogen Intake Pressure Sensor Circuit Short to Ground If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen tank pressure sensor (for inlet side) circuit remains at less than 0.15 V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen tank pressure sensor (for inlet side)

·

Hydrogen fuel control ECU assembly

·

Wire harness or connector


Master Warning: Comes on Hydrogen Filling Control A
P1DFA15 Hydrogen Intake Pressure Sensor Circuit Short to Battery or Open If the +B voltage is not low when the ignition switch is ON, the output voltage of the hydrogen tank pressure sensor (for inlet side) circuit remains at more than 4.85V for more than 3 seconds.
(1 trip detection logic)
·

Hydrogen tank pressure sensor (for inlet side)

·

Hydrogen fuel control ECU assembly

·

Wire harness or connector


Master Warning: Comes on Hydrogen Filling Control A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List (EV)
"FC Work Mode"
Stop Startup Working Finishing
Data List (EV)
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ ○

Related Data List
DTC No. Data List
P1DFA11 Hydrogen Intake Pressure Sensor Voltage
P1DFA15

HINT:

If DTCs are found, read the "Hydrogen Intake Pressure Sensor Voltage" in the Data List on a GTS.


Hydrogen Intake Pressure Sensor Voltage Malfunction
Less than 0.15 V
·

Open in VHPC (5 V power supply) circuit

·

Short in HPC circuit to ground

·

Short in HPC circuit to GHPC (GND) circuit


Higher than 4.85 V
·

Short in VHPC circuit to HPC circuit

·

Open in HPC circuit

·

Open in GHPC (GND) circuit



HINT:

It is suspected that malfunctions, or open/short circuits have occurred in the hydrogen tank pressure sensor (for inlet side).


WIRING DIAGRAM

A477012E02
5.844,0.854 6.302,1.052 0.458,0.198 10 false 5 V 5.854,1.563 6.313,1.76 0.458,0.198 10 false 5 V 0.344,2.927 1,3.125 0.656,0.198 10 false G2 0.333,3.083 1.875,3.635 1.542,0.552 10 false Hydrogen Tank Pressure Sensor (for Inlet Side) 0.292,4.385 1.667,4.583 1.375,0.198 10 false *: Shield Ground 3.333,3.375 3.646,3.573 0.313,0.198 10 false * 4.396,3.927 4.854,4.125 0.458,0.198 10 false G4 4.417,4.083 6.833,4.51 2.417,0.427 10 false Hydrogen Fuel Control ECU Assembly 4.323,3.073 4.635,3.271 0.313,0.198 10 false 25 4.594,3.083 5.208,3.281 0.615,0.198 10 false SDRN 1.219,1.219 1.833,1.417 0.615,0.198 10 false VHPC 1.292,1.958 1.75,2.156 0.458,0.198 10 false HPC 1.198,2.604 1.813,2.802 0.615,0.198 10 false GHPC 1.729,1.104 1.885,1.302 0.156,0.198 10 false 3 1.729,1.875 1.885,2.073 0.156,0.198 10 false 2 1.729,2.5 1.885,2.698 0.156,0.198 10 false 1 4.583,1.135 5.198,1.333 0.615,0.198 10 false VHPC 4.625,1.865 5.083,2.063 0.458,0.198 10 false HPC 4.594,2.5 5.208,2.698 0.615,0.198 10 false GHPC 4.313,1.125 4.625,1.323 0.313,0.198 10 false 11 4.302,1.854 4.615,2.052 0.313,0.198 10 false 27 4.313,2.49 4.625,2.688 0.313,0.198 10 false 26

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON and wait for 1 minute or more.



PROCEDURE

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HYDROGEN TANK PRESSURE SENSOR (FOR INLET SIDE))

Pre-procedure1

a.
A476959

Disconnect the hydrogen tank pressure sensor (for inlet side) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G2)Location & Routing

Click Connector(G2)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Tube Joint Assembly

G2-3 (VHPC) - G2-1 (GHPC) Ignition switch ON 4.75 to 5.25 V
G2-2 (HPC) - G2-1 (GHPC) Ignition switch ON 4.75 to 5.25 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen tank pressure sensor (for inlet side) connector.



OK

2.REPLACE HYDROGEN TANK TUBE JOINT ASSEMBLY (HYDROGEN TANK PRESSURE SENSOR (FOR INLET SIDE))

NG

5.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - HYDROGEN TANK PRESSURE SENSOR (FOR INLET SIDE))
2.REPLACE HYDROGEN TANK TUBE JOINT ASSEMBLY (HYDROGEN TANK PRESSURE SENSOR (FOR INLET SIDE))
HINT:

Click hereEngine / Hybrid System>FUEL>TUBE JOINT (for Inlet Side)>REMOVAL


Result:
Proceed to
NEXT



NEXT

3.CLEAR DTC
3.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > Hydrogen Filling Control > Clear DTCs
50002 494
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

4.CHECK DTC OUTPUT
4.CHECK DTC OUTPUT

Pre-procedure1

a.

Turn the ignition switch to ON and wait for 1 minute or more.


Procedure1

a.

Check for DTCs.

Powertrain > Hydrogen Filling Control > Trouble Codes
50001 494
Result:
Result Proceed to
P1DFA11 or P1DFA15 is output A
DTCs are not output B



Post-procedure1

a.

Turn the ignition switch off.



A

REPLACE HYDROGEN FUEL CONTROL ECU ASSEMBLY

B

END

5.CHECK HARNESS AND CONNECTOR (HYDROGEN FUEL CONTROL ECU ASSEMBLY - HYDROGEN TANK PRESSURE SENSOR (FOR INLET SIDE))

Pre-procedure1

a.

Disconnect the hydrogen fuel control ECU assembly connector.


b.

Disconnect the hydrogen tank pressure sensor (for inlet side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G4,G2)Location & Routing

Click Connector(G4)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Fuel Control ECU Assembly

Click Connector(G2)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Tank Tube Joint Assembly

G4-27 (HPC) - G2-2 (HPC) Always Below 1 Ω
G4-26 (GHPC) - G2-1 (GHPC) Always Below 1 Ω
G4-11 (VHPC) - G2-3 (VHPC) Always Below 1 Ω
G4-27 (HPC) or G2-2 (HPC) - Body ground and other terminals Always 10 kΩ or higher
G4-11 (VHPC) or G2-3 (VHPC) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen tank pressure sensor (for inlet side) connector.


b.

Reconnect the hydrogen fuel control ECU assembly connector.



OK

REPLACE HYDROGEN FUEL CONTROL ECU ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR