The hydrogen system of the FC system feeds the FC stack with hydrogen, so that the FC stack can generate power. The tank shut valve is a valve that opens or closes so as to allow compressed hydrogen to flow from the hydrogen tank to the FC stack when the system is in operation. The tank shut valve is provided on each of the 3 hydrogen tank assemblies, and it will open when the system starts operating, and will close when the system shuts off.
If either one of the tank shut valves remains stuck open due to mechanical malfunctions, changes in the hydrogen pressure will cause a DTC to set.
Tank shut valve 1 is built into the No. 1 hydrogen tank assembly, tank shut valve 2 is built into the No. 2 hydrogen tank assembly and tank shut valve 3 is built into the No. 3 hydrogen tank assembly.
For the circuit diagram, refer to DTC P1E4000.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1E4000
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1E367E | Tank Shut Valve 1 Actuator Stuck On | Detects a malfunction where any single tank shut valve does not close:
When the ignition switch is turned from ON (READY)(Working) to off, a change in the high-range hydrogen pressure is small. (1 trip detection logic) |
·
No. 1 hydrogen tank assembly (tank shut valve 1) ·
No. 2 hydrogen tank assembly (tank shut valve 1) ·
No. 3 hydrogen tank assembly (tank shut valve 3) |
Master Warning: Comes on | EV | B |
If all tank shut valves do not open, the FC system will shut off.
If any single tank shut valve does not open, the distance the vehicle can travel will be shorter.
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | - | - | - | - | ○ |
By accessing the "FC Work Mode" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1E367E | ·
High-Range Hydrogen Pressure (Filtered Value) ·
Tank Shut Valve 1 Drive Status ·
Tank Shut Valve 2 Drive Status ·
Tank Shut Valve 3 Drive Status |
I f all of the tank shut valves 1, 2 and 3 do not open, the "High-Range Hydrogen Pressure (Filtered Value)" will not increase and the FC system will be unable to start.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Forcing the SOC of the EV supply battery assembly to decrease by applying electrical loads such as turning on the air conditioning (HOT MAX, maximum airflow), or depressing the accelerator pedal with the shift state in park (P), the "FC Intermittent Operation" of the Data List is easily to enter OFF (power generation mode).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Mode" is FC Working.
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY).
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Result | Proceed to |
|---|---|
| Only P1E367E is output | A |
| P1E367E is output and DTCs other than the DTCs in the table below are output | B |
| P1E367E is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1E0012 (Hydrogen Filling Control) | Tank Shut Valve 1 Circuit Short to Battery |
| P1E0014 (Hydrogen Filling Control) | Tank Shut Valve 1 Circuit Short to Ground or Open | |
| P1E1012 (Hydrogen Filling Control) | Tank Shut Valve 2 Circuit Short to Battery | |
| P1E1014 (Hydrogen Filling Control) | Tank Shut Valve 2 Circuit Short to Ground or Open | |
| P1E5A12 (Hydrogen Filling Control) | Tank Shut Valve 3 Circuit Short to Battery | |
| P1E5A14 (Hydrogen Filling Control) | Tank Shut Valve 3 Circuit Short to Ground or Open | |
| System malfunction | P1DB01C (EV) | High-Range Hydrogen Pressure Sensor Circuit Voltage Out of Range |
DTC P1E367E may be store due to problems that cause the DTCs shown above to output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
Turn the ignition switch to ON (READY).
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| High-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of High-Range Hydrogen Pressure (Filtered Value) is less than 10000 kPa(abs) | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Fill the tank until the "High-Range Hydrogen Pressure (Filtered Value)" in the Data List exceeds 10000 kPa(abs).
| Proceed to |
|---|
| NEXT |
NEXT
This procedure is for troubleshooting tank shut valve 1 that has stuck open.
Close the manual valves on the No. 2 hydrogen tank assembly and No. 3 hydrogen tank assembly to check the pressure of the No. 1 hydrogen tank assembly.
Pre-procedure1
Clear the DTCs.
Remove the under cover.
| *1 | No. 2 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 2 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
| *1 | No. 3 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 3 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working.
| Tester Display |
|---|
| FC Work Mode |
| High-Range Hydrogen Pressure (Filtered Value) |
Record the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (1)
Turn the ignition switch off and wait for 10 minutes or more.
After the ignition switch is turned off, the "High-Range Hydrogen Pressure (Filtered Value)" is reduced to depressurized by 5000 to 10000 kPa due to system shutdown control.
Turn the ignition switch to ON.
Read the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (2)
| Tester Display |
|---|
| High-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List decreases from the value recorded in (1) | A |
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List is the same as the value recorded in (1) | B |
If normal, the "High-Range Hydrogen Pressure (Filtered Value)" is decreased by 5000 to 10000 kPa due to system shutdown control.
Turn the ignition switch off.
Post-procedure1
| *1 | No. 2 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 2 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
| *1 | No. 3 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 3 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Install the under cover.
A
B
This procedure is for troubleshooting tank shut valve 2 that has stuck open.
Close the manual valves on the No. 1 hydrogen tank assembly and No. 3 hydrogen tank assembly to check the pressure of the No. 2 hydrogen tank assembly.
Pre-procedure1
Clear the DTCs.
Remove the under cover.
| *1 | No. 1 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 1 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *1 | No. 3 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 3 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working.
| Tester Display |
|---|
| FC Work Mode |
| High-Range Hydrogen Pressure (Filtered Value) |
Record the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (1)
Turn the ignition switch off and wait for 10 minutes or more.
After the ignition switch is turned off, the "High-Range Hydrogen Pressure (Filtered Value)" is reduced to depressurized by 5000 to 10000 kPa due to system shutdown control.
Turn the ignition switch to ON.
Read the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (2)
| Tester Display |
|---|
| High-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List decreases from the value recorded in (1) | A |
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List is the same as the value recorded in (1) | B |
If normal, the "High-Range Hydrogen Pressure (Filtered Value)" is decreased by 5000 to 10000 kPa due to system shutdown control.
Turn the ignition switch off.
Post-procedure1
| *1 | No. 1 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 1 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *1 | No. 3 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 3 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 3 hydrogen tank assembly must be replaced.
Install the under cover.
A
B
This procedure is for troubleshooting tank shut valve 3 that has stuck open.
Close the manual valves on the No. 1 hydrogen tank assembly and No. 2 hydrogen tank assembly to check the pressure of the No. 3 hydrogen tank assembly.
Pre-procedure1
Clear the DTCs.
Remove the under cover.
| *1 | No. 1 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 1 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *1 | No. 2 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Open |
| *c | Manual Valve Closed |
| *d | Clockwise |
Using an 8 mm hexagon socket wrench, rotate the adjustment bolt clockwise to close the manual valve of the No. 2 hydrogen tank assembly.
20 N*m (204 kgf*cm, 15 ft.*lbf)
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
Procedure1
Turn the ignition switch to ON (READY) with the shift lever in P, and check that the Data List "FC Work Mode" is Working.
| Tester Display |
|---|
| FC Work Mode |
| High-Range Hydrogen Pressure (Filtered Value) |
Record the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (1)
Turn the ignition switch off and wait for 10 minutes or more.
After the ignition switch is turned off, the "High-Range Hydrogen Pressure (Filtered Value)" is reduced to depressurized by 5000 to 10000 kPa due to system shutdown control.
Turn the ignition switch to ON.
Read the "High-Range Hydrogen Pressure (Filtered Value)" of the Data List. (2)
| Tester Display |
|---|
| High-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List decreases from the value recorded in (1) | A |
| The value of "High-Range Hydrogen Pressure (Filtered Value)" (2) in the Data List is the same as the value recorded in (1) | B |
If normal, the "High-Range Hydrogen Pressure (Filtered Value)" is decreased by 5000 to 10000 kPa due to system shutdown control.
Post-procedure1
Turn the ignition switch off.
| *1 | No. 1 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 1 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 1 hydrogen tank assembly must be replaced.
| *1 | No. 2 Hydrogen Tank Assembly |
| *a | Adjustment Bolt |
| *b | Manual Valve Closed |
| *c | Manual Valve Open |
| *d | Counterclockwise |
Using an 8 mm socket hexagon wrench, rotate the adjustment bolt counterclockwise until it contacts the plug, and open the No. 2 hydrogen tank assembly manual valve.
The manual valve is the component that shuts off the pressure from the hydrogen tank assembly, so be careful not to damage the hexagonal portion.
If the hexagonal portion has been damaged, the No. 2 hydrogen tank assembly must be replaced.
Install the under cover.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B