The hydrogen system of the FC system feeds the FC stack with hydrogen, so that the FC stack can generate power.
The hydrogen supply line, which is from the tank shut valves up to the hydrogen injectors, are maintained at a higher hydrogen pressure than the pressure applied to the FC stack, and it consists of the high-range pressure area where the pressure equal to the hydrogen tank pressure is applied, and the medium-range pressure area.
Pressures in the hydrogen supply line located between the tank shut valves and hydrogen injectors are monitored by the system, and if the monitored pressure has decreased excessively, this will be interpreted as occurrence of a large amount of hydrogen leakage due to damage in the line, and the DTC will be stored.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *3 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *4 | No. 1 Hydrogen Tank Assembly |
| *5 | No. 2 Hydrogen Tank Assembly | *6 | No. 3 Hydrogen Tank Assembly |
| *7 | Hydrogen Tank Temperature Sensor 1 | *8 | Hydrogen Tank Temperature Sensor 2 |
| *9 | Hydrogen Tank Temperature Sensor 3 | *10 | Tank Shut Valve 1 |
| *11 | Tank Shut Valve 2 | *12 | Tank Shut Valve 3 |
| *13 | Hydrogen Supply Regulator Assembly | *14 | Hydrogen Primary Pressure Sensor |
| *15 | Fuel Injector Assembly | *16 | Hydrogen Secondary Pressure Sensor |
| *17 | FC Stack | *18 | Hydrogen Recirculation Pump Assembly |
| *19 | Exhaust Drainage Valve (Hydrogen Recirculation Separator Assembly) | *20 | FC Air Pressure Regulator Assembly (Air Pressure Regulating Valve) |
| *21 | FC Air Pressure Regulator Assembly (Air Sealing Valve) | *22 | FC Air By-pass Valve Assembly (Air Shunt Valve) |
| *23 | Pressure Relief Valve | *24 | Manual Valve |
| *25 | Pressure Relief Device | - | - |
| *a | Hydrogen System | *b | Air System |
| *c | From the FC Air Compressor with Motor Assembly | *d | To the Exhaust Drainage Pipe |
| *e | Hydrogen Supply Line | *f | High-range Pressure Area |
| *g | Medium-range Pressure Area | - | - |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1E427A | Hydrogen Leak (Excessive Hydrogen Flow) Fluid Leak or Seal Failure | Pressure is monitored all the time while the FC is operating, and the DTC will be output if the high-range or medium-range hydrogen pressure has decreased abruptly.
(1 trip detection logic) |
·
High-range hydrogen pressure pipe ·
Medium-range hydrogen pressure pipe ·
Hydrogen tank pressure sensor (for outlet side) ·
Hydrogen primary pressure sensor ·
Sealed area of each component |
Master Warning: Comes on | EV | B |
This DTC indicates leaks in the high- and medium-range hydrogen pressure system, which covers from the hydrogen tanks to hydrogen injectors.
Troubleshoot hydrogen leaks from the high-range pressure area first.
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | - | ○ | ○ | ○ | - |
By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1E427A | ·
Tank Shut Valve 1 Drive Status ·
Tank Shut Valve 2 Drive Status ·
Tank Shut Valve 3 Drive Status ·
Hydrogen Injector 1 Injection Period ·
Hydrogen Injector 2 Injection Period ·
Hydrogen Injector 3 Injection Period ·
Target Low-Range Hydrogen Pressure ·
High-Range Hydrogen Pressure (Filtered Value) ·
Medium-Range Hydrogen Pressure (Filtered Value) ·
Motor Room Hydrogen Density ·
Tank Area 1 Hydrogen Density ·
Tank Area 2 Hydrogen Density |
By performing the instructions below, leaks from the high- or medium-range hydrogen pressure system can be identified to some extent by the changes in the "High-Range Hydrogen Pressure (Filtered Value)" and "Medium-Range Hydrogen Pressure (Filtered Value)" with the ignition switch ON.
Turn the ignition switch to ON (READY) with the shift state in park (P).
Turn the ignition switch off.
Turn the ignition switch to ON and observe changes in the "High-Range Hydrogen Pressure (Filtered Value)" and "Medium-Range Hydrogen Pressure (Filtered Value)" in the Data List.
When the ignition switch is ON, as the tank shut valves and hydrogen injectors are closed, the high- and medium-range hydrogen pressures do not show significant variations in their values, and they are stable.
If hydrogen leakage is suspected, the FC system forces all tank shut valves and hydrogen injectors to close and a decrease in the pressure will be checked during the FC Startup Process.
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Click hereEngine / Hybrid System>FUEL>FUEL SYSTEM>PRECAUTION
This DTC indicates a large amount of hydrogen leakage, so perform operations in a well-ventilated area and listen carefully for the sound of leaking hydrogen gas. Use a hydrogen gas detector, and be extremely cautions due to possible hydrogen gas leaks.
After completion of repair, check that no hydrogen leaks from the hydrogen pipes using a hydrogen gas detector.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working. Then, wait for 1 minute or more (If FC system cannot be activated, check the DTCs that are present at the time).
Turn the ignition switch off and wait for 10 minutes or more.
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Result | Proceed to |
|---|---|
| Only P1E427A is output | A |
| P1E427A is output and DTCs other than the DTCs in the table below are output | B |
| P1E427A is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1DB011 (FC) | High-Range Hydrogen Pressure Sensor Circuit Short to Ground |
| P1DB015 (FC) | High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | |
| P1DB511 (FC) | Medium-Range Hydrogen Pressure Sensor Circuit Short to Ground | |
| P1DB515 (FC) | Medium-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | |
| P1D9A1C (FC) | Hydrogen Injector 1 Circuit Voltage Out of Range | |
| P1DA01C (FC) | Hydrogen Injector 2 Circuit Voltage Out of Range | |
| P1DA51C (FC) | Hydrogen Injector 3 Circuit Voltage Out of Range | |
DTC P1E427A may be store due to problems that cause the DTCs shown above to output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
OK
NG
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Open the hood with the ignition switch off, check for hydrogen leaks around the underbody and in the front compartment with a hydrogen gas detector. If leakage is found, pay extra attention to fire safety in the following operations.
For procedures to check for leaks from hydrogen pipes and components (high-range pressure and medium-range pressure), refer toEngine / Hybrid System>FUEL>FUEL SYSTEM>ON-VEHICLE INSPECTION.
Pre-procedure1
Turn the ignition switch off.
Remove the under cover.
Procedure1
Check that the hydrogen tank and hydrogen pipes are not damaged.
Check for a gas leaking sound, and then check if there are hydrogen leaks in the hydrogen pipes and components with a hydrogen gas detector.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | High-range Hydrogen Pressure Pipe (for filling) |
| *3 | Hydrogen Tank Tube Joint | *4 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *5 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *6 | No. 1 Hydrogen Tank Assembly |
| *7 | No. 2 Hydrogen Tank Assembly | *8 | No. 3 Hydrogen Tank Assembly |
| *9 | High-range Hydrogen Pressure Pipe (for feeding) | *10 | Hydrogen Supply Regulator Assembly |
| *11 | Medium-range Hydrogen Pressure Pipe | *12 | Low-range Hydrogen Pressure Pipe |
| *13 | FC Stack Assembly | *14 | Hydrogen Injector |
| *a | High-range Pressure Area (when filling)
(Hydrogen Inlet Receptacle Assembly → Hydrogen Tank Assembly ) |
*b | High-range Pressure Area
(Hydrogen Tank Assembly → Hydrogen Supply Regulator Assembly) |
| *c | Medium-range Pressure Area
(Hydrogen Supply Regulator Assembly → Hydrogen Injector) |
*d | Low-range Pressure Area
(Hydrogen Injector → FC Stack) |
300 ppm or less. (Hydrogen gas detector)
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the under cover.
OK
NG
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Open the hood with the ignition switch off, check for hydrogen leaks around the underbody and in the front compartment with a hydrogen gas detector. If leakage is found, pay extra attention to fire safety in the following operations.
Turn the ignition switch to ON (READY) causes the tank shut valve to open, and this pressurizes hydrogen in the hydrogen pipes. At this time, locate leaking areas of the hydrogen pipe. If there are leaks, the hydrogen pressure in the pipe decreases gradually, so perform checks quickly.
For procedures to check for leaks from hydrogen pipes and components (high-range pressure and medium-range pressure), refer toEngine / Hybrid System>FUEL>FUEL SYSTEM>ON-VEHICLE INSPECTION.
Pre-procedure1
Remove the under cover.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
If there are no leaks, the high-range and medium-range hydrogen systems will be pressurized full in virtually a few seconds after the ignition switch is turned to ON (READY) (the tank shut valves open). For the low-range hydrogen system, after the ignition switch is turned to ON (READY), when the "FC Work Mode" in the Data List enters Working and Intermittent Operation turns OFF, the hydrogen injector is caused to open so that hydrogen can be supplied.
Turn the ignition switch off.
Procedure1
Check for a gas leaking sound, and then check if there are hydrogen leaks in the hydrogen pipes and components with a hydrogen gas detector.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | High-range Hydrogen Pressure Pipe (for filling) |
| *3 | Hydrogen Tank Tube Joint | *4 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *5 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *6 | No. 1 Hydrogen Tank Assembly |
| *7 | No. 2 Hydrogen Tank Assembly | *8 | No. 3 Hydrogen Tank Assembly |
| *9 | High-range Hydrogen Pressure Pipe (for feeding) | *10 | Hydrogen Supply Regulator Assembly |
| *11 | Medium-range Hydrogen Pressure Pipe | *12 | Low-range Hydrogen Pressure Pipe |
| *13 | FC Stack Assembly | *14 | Hydrogen Injector |
| *a | High-range Pressure Area (when filling)
(Hydrogen Inlet Receptacle Assembly → Hydrogen Tank Assembly ) |
*b | High-range Pressure Area
(Hydrogen Tank Assembly → Hydrogen Supply Regulator Assembly) |
| *c | Medium-range Pressure Area
(Hydrogen Supply Regulator Assembly → Hydrogen Injector) |
*d | Low-range Pressure Area
(Hydrogen Injector → FC Stack) |
300 ppm or less. (Hydrogen gas detector)
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the under cover.
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Pre-procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
If there are no leaks, the high-range and medium-range hydrogen systems will be pressurized full in virtually a few seconds after the ignition switch is turned to ON (READY) (the tank shut valves open). For the low-range hydrogen system, after the ignition switch is turned to ON (READY), when the "FC Work Mode" in the Data List enters Working and Intermittent Operation turns OFF, the hydrogen injector is caused to open so that hydrogen can be supplied.
Turn the ignition switch off.
Procedure1
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
Post-procedure1
None
NEXT
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
NEXT