Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1D251C  Radiator Outlet Coolant Temperature Sensor Circuit Voltage Out of Range  


DESCRIPTION

The cooling system of the FC system controls the FC stack temperature so that it can remain at optimum for power generation.

The 2 coolant temperature sensors are used to monitor coolant temperatures at the FC stack outlet, which has increased due to FC stack cooling, and at the radiator outlet, which has been decreased by the radiator, for controlling the FC system temperature at a proper level.

If a coolant temperature sensor value has deviated from another temperature sensor value that is supposed to be equal to the said sensor value under specified conditions, this DTC will be stored.

For the circuit diagram, refer to DTC P1D2F00.

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D2F00

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1D251C Radiator Outlet Coolant Temperature Sensor Circuit Voltage Out of Range When the system is activated after at least 6 hours have elapsed with the ignition switch off, the FC stack coolant temperature (radiator outlet) and the ambient temperature sensor value (for air conditioning) are significantly different.
(3 trip detection logic)
Water temperature sensor (for radiator outlet side) Master Warning: Comes on EV B

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List
"FC Work Mode"
Stop Startup Working Finishing
Data List
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection - ○ - - - -

HINT:

By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.


Related Data List
DTC No. Data List
P1D251C
·

FC Stack Outlet Coolant Temperature (Filtered Value)

·

Radiator Outlet Coolant Temperature (Filtered Value)



Related Active Test
DTC No. Active Test
P1D251C Control the Radiator Rotary Valve

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After performing repairs, clear the DTCs, perform the following procedure, and then check the data list items "Radiator Outlet Coolant Temperature (Filtered Value)" and "FC Stack Outlet Coolant Temperature (Filtered Value)".

1.

Turn the ignition switch off, and leave the vehicle for at least 8 hours in an environment with an ambient temperature of more than 10°C (50°F).

HINT:

The coolant passage which is monitored by the water temperature sensor (radiator outlet) is easily influenced by ambient air, and the temperature decreases significantly. For that reason, if the ambient temperature is less than 10°C (50°F), the temperature sensor value will significantly deviate from the water temperature sensor (FC stack outlet) value, as a result, these sensor values cannot be compared each other.


2.

Check that the difference between the "Radiator Outlet Coolant Temperature (Filtered Value)" and the "FC Stack Outlet Coolant Temperature (Filtered Value)" is less than 10°C (18°F).



PROCEDURE

1.CHECK DTC OUTPUT
NOTICE:

The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.


Pre-procedure1

a.

None


Procedure1

a.

According to the display on the GTS, check for DTCs in the Health Check.

Result:
Result Proceed to
Only P1D251C is output A
P1D251C is output and DTCs other than the DTCs in the table below are output B
P1D251C is output and any DTCs in the table below are output C

Malfunction Content Relevant DTC
Sensor and actuator circuit malfunction P1D2511 (EV) Radiator Outlet Coolant Temperature Sensor Circuit Short to Ground
P1D2515 (EV) Radiator Outlet Coolant Temperature Sensor Circuit Short to Battery or Open



Post-procedure1

a.

Turn the ignition switch off.



A

2.CLEAR DTC

B

2.CLEAR DTC

C

GO TO DTC CHART

2.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > EV > Clear DTCs
50002 397
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

3.CHECK DTC OUTPUT (AIR CONDITIONING SYSTEM)
3.CHECK DTC OUTPUT (AIR CONDITIONING SYSTEM)
NOTICE:

The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.


Pre-procedure1

a.

None


Procedure1

a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121
Result:
Result Proceed to
DTCs are not output A
B1412 is output B



Post-procedure1

a.

Turn the ignition switch off.



A

4.INSPECT WATER TEMPERATURE SENSOR (FOR RADIATOR OUTLET SIDE)

B

4.INSPECT WATER TEMPERATURE SENSOR (FOR RADIATOR OUTLET SIDE)

OK

NG