Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1DDE31  Hydrogen Detector Sensor "B" No Signal  


DESCRIPTION

Refer to DTC P1DCA31.

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1DCA31

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1DDE31 Hydrogen Detector Sensor "B" No Signal All of the following conditions are met, and the output frequency of the hydrogen detector (for hydrogen tank 3 side) is less than 0.75 kHz and such a frequency continues for 3 seconds or more:
·

+B voltage is not low

·

2 seconds or more after starting the EV control ECU


(1 trip detection logic)
·

Hydrogen detector (for hydrogen tank 3 side)

·

EV control ECU

·

Wire harness or connector


Master Warning: Comes on EV A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List
"FC Work Mode"
Stop Startup Working Finishing
Data List
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ -

Related Data List
DTC No. Data List
P1DDE31 Hydrogen Detector 2 Frequency

WIRING DIAGRAM

A477028E09
4.76,2.948 5.219,3.146 0.458,0.198 10 false G14*1 4.76,3.115 5.927,3.417 1.167,0.302 10 false EV Control ECU 4.75,2.198 5.208,2.396 0.458,0.198 10 false ED3 4.49,2.198 4.802,2.396 0.313,0.198 10 false 33 4.771,1.698 5.219,1.906 0.448,0.208 10 false HD3 4.49,1.698 4.948,1.896 0.458,0.198 10 false 26 4.781,1.104 5.396,1.302 0.615,0.198 10 false VD3 4.5,1.094 4.813,1.292 0.313,0.198 10 false 16 0.427,2.719 0.885,2.917 0.458,0.198 10 false G11 0.427,2.885 3.344,3.146 2.917,0.26 10 false Hydrogen Detector (for Hydrogen Tank 3 Side) 2.875,2.208 3.031,2.406 0.156,0.198 10 false 4 2.479,2.198 2.938,2.396 0.458,0.198 10 false GND 2.885,1.667 3.042,1.865 0.156,0.198 10 false 1 2.49,1.667 2.896,1.865 0.406,0.198 10 false HD3 2.875,1.115 3.063,1.354 0.188,0.24 10 false 3 2.479,1.208 2.896,1.396 0.417,0.188 10 false VD3 5.479,0.823 5.938,1.021 0.458,0.198 10 false 5 V 5.458,1.406 5.917,1.604 0.458,0.198 10 false 5 V 5.229,2.948 5.688,3.146 0.458,0.198 10 false A14*2 3.563,3.052 4.385,3.24 0.823,0.188 10 false *1: for LHD 3.552,3.365 4.375,3.552 0.823,0.188 10 false *2: for RHD

CAUTION / NOTICE / HINT

NOTICE:
·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON and wait for 30 seconds or more.



PROCEDURE

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE))

Pre-procedure1

a.
A477025

Disconnect the hydrogen detector (for hydrogen tank 3 side) connector.


b.

Turn the ignition switch to ON.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(G11)Location & Routing

Click Connector(G11)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (NO.3)

G11-3 (VD3) - G11-4 (GND) Ignition switch ON 4.8 to 5.2 V
G11-1 (HD3) - G11-4 (GND) Ignition switch ON 4.8 to 5.2 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

Turn the ignition switch off.


b.

Reconnect the hydrogen detector (for hydrogen tank 3 side) connector.



OK

2.REPLACE HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE)

NG

5.CONFIRM MODEL
2.REPLACE HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE)

NEXT

3.CLEAR DTC
3.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > EV > Clear DTCs
50002 397
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

4.CHECK DTC OUTPUT
4.CHECK DTC OUTPUT

Pre-procedure1

a.

None


Procedure1

a.

Check for DTCs.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P1DDE31 is output A
DTCs are not output B



Post-procedure1

a.

Turn the ignition switch off.



A

B

END

5.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD A
for RHD B



A

6.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE))

B

7.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE))
6.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.

Disconnect the hydrogen detector (for hydrogen tank 3 side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(G14,G11)Location & Routing

Click Connector(G14)Instrument Panel>Floor Wire>EV Control ECU

Click Connector(G11)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (NO.3)

G14-16 (VD3) - G11-3 (VD3) Always Below 1 Ω
G14-26 (HD3) - G11-1 (HD3) Always Below 1 Ω
G14-33 (ED3) - G11-4 (GND) Always Below 1 Ω
G14-16 (VD3) or G11-3 (VD3) - Body ground and other terminals Always 10 kΩ or higher
G14-26 (HD3) or G11-1 (HD3) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen detector (for hydrogen tank 3 side) connector.


b.

Reconnect the EV control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (EV CONTROL ECU - HYDROGEN DETECTOR (FOR HYDROGEN TANK 3 SIDE))

Pre-procedure1

a.

Disconnect the EV control ECU connector.


b.

Disconnect the hydrogen detector (for hydrogen tank 3 side) connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(A14,G11)Location & Routing

Click Connector(A14)Instrument Panel>Front Compartment Main Wire>EV Control ECU

Click Connector(G11)Body>Floor Wire / No. 3 Floor Wire>Hydrogen Detector (NO.3)

A14-16 (VD3) - G11-3 (VD3) Always Below 1 Ω
A14-26 (HD3) - G11-1 (HD3) Always Below 1 Ω
A14-33 (ED3) - G11-4 (GND) Always Below 1 Ω
A14-16 (VD3) or G11-3 (VD3) - Body ground and other terminals Always 10 kΩ or higher
A14-26 (HD3) or G11-1 (HD3) - Body ground and other terminals Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the hydrogen detector (for hydrogen tank 3 side) connector.


b.

Reconnect the EV control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR