Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1F4A1F  Fuel Cell Control Module Power Relay Sense Circuit Intermittent  


DESCRIPTION

The FC control ECU monitors the +B power source voltage and detects a momentary interruption.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1F4A1F Fuel Cell Control Module Power Relay Sense Circuit Intermittent The FC control ECU was reset due to a momentary interruption of the power supply while the ignition switch is ON (READY).
(1 trip detection logic)
·

Auxiliary battery

·

FC-B relay

·

IGCT NO. 2 relay

·

FC control ECU

·

Wire harness or connector


Master Warning: Comes on FC A

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List (EV)
"FC Work Mode"
Stop Startup Working Finishing
Data List (EV)
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection ○ ○ ○ ○ ○ -

WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following procedure.

·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

Turn the ignition switch to ON (READY) and wait for 30 seconds or more.



PROCEDURE

1.CHECK AUXILIARY BATTERY TERMINAL
a.

Confirm whether the auxiliary battery terminals have been disconnected recently.


Result:
Result Proceed to
Terminals have been disconnected A
Terminals have not been disconnected B



A

2.CHECK WARNING LIGHT (MASTER WARNING LIGHT)

B

4.CHECK DTC OUTPUT
2.CHECK WARNING LIGHT (MASTER WARNING LIGHT)

Pre-procedure1

a.

With the ignition switch off, turn the ignition switch to ON (READY) and wait for 30 seconds or more.


Procedure1

a.

Confirm that the master warning light illuminates.

Result:
Result Proceed to
Master warning light illuminates A
Master warning light does not illuminate B


HINT:

DTC P1F4A1F may be stored after disconnecting and reconnecting the auxiliary battery terminals. If this happens, the DTC will not be output if the ignition switch is turned off and then to ON (READY) again. In this case, clear DTCs to complete the inspection.



Post-procedure1

a.

Turn the ignition switch off.



A

3.CLEAR DTC

B

END

3.CLEAR DTC

Pre-procedure1

a.

None


Procedure1

a.

Clear the DTCs.

Powertrain > FC > Clear DTCs
50002 490
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

4.CHECK DTC OUTPUT
4.CHECK DTC OUTPUT

Pre-procedure1

a.

Turn the ignition switch to ON (READY) and wait for 30 seconds or more.


Procedure1

a.

Check for DTCs.

Powertrain > FC > Trouble Codes
50001 490
Result:
Result Proceed to
Only P1F4A1F is output A
P1F4A1F and other DTCs are output B



Post-procedure1

a.

Turn the ignition switch off.



A

5.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)

B

GO TO DTC CHART

5.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)
a.

Check the connection of the auxiliary battery terminal.

OK:

The terminal is connected securely and there is no contact problem.



Result:
Proceed to
OK
NG



OK

6.CHECK CONNECTOR CONNECTION CONDITION (FC CONTROL ECU)

NG

CONNECT SECURELY

6.CHECK CONNECTOR CONNECTION CONDITION (FC CONTROL ECU)
a.
A476938

Check the connection condition of the FC control ECU connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

NOTICE:

Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.


OK:

- The connector is connected securely.

- The terminals are not deformed and are connected securely.

- No water or foreign matter in the connector.


HINT:

When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.



Result:
Result Proceed to
OK A
NG (The connector is not connected securely) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) C



A

7.INSPECT RELAY (FC-B RELAY)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.INSPECT RELAY (FC-B RELAY)

OK

8.CHECK CONNECTOR CONNECTION CONDITION (FC CONTROL ECU - FC-B RELAY)

NG

REPLACE RELAY (FC-B RELAY)

8.CHECK CONNECTOR CONNECTION CONDITION (FC CONTROL ECU - FC-B RELAY)

Pre-procedure1

a.

Disconnect the FC control ECU connector.


b.

Remove the FC-B relay from the No. 1 front compartment relay block.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition

Click Location & Routing(B1)Location & Routing

Click Connector(B1)Engine Compartment>No. 2 Stack Wire>FC Control ECU

B1-43 (+B1) - 5 (FC-B relay holder) Ignition switch off Below 1 Ω
B1-83 (+B2) - 5 (FC-B relay holder) Ignition switch off Below 1 Ω


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the FC-B relay.


b.

Connect the FC control ECU connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR