The EV control ECU regulates the hydrogen pump inverter through use of communication signals, operating the hydrogen pump motor.
Based on the diagnostic information that can be obtained from the hydrogen pump inverter through LIN communication, the EV control ECU detects malfunctions in the hydrogen pump inverter or hydrogen pump.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D8396 | Hydrogen Pump Inverter Component Internal Failure | A signal indicating that the hydrogen pump inverter has detected a malfunction is received for 2 seconds or more continuously under the following conditions:
·
"FC Work Mode" is in FC Startup Process or Working ·
Communication with the hydrogen pump inverter is normal (1 trip detection logic) |
·
Hydrogen recirculation pump assembly ·
Hydrogen pump inverter assembly |
Master Warning: Comes on | EV | B |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | ○ | ○ | ○ | ○ | - |
By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1D8396 | ·
Hydrogen Pump Speed ·
Target Hydrogen Pump Speed ·
Hydrogen Pump Main Power Supply Status ·
Hydrogen Pump Output Status ·
Hydrogen Pump Load Status ·
Hydrogen Pump LIN Communication Control ·
Hydrogen Pump CPU Abnormal ·
Hydrogen Pump Inverter Over Temperature Status |
| DTC No. | Active Test |
|---|---|
| P1D8396 | Control the Hydrogen Pump |
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.
Make sure to remove the EV supply battery assembly service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (w/ 1500W Type Voltage Inverter)
After removing the service plug grip from the EV supply battery assembly, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the FC converter power outlet cable (inverter with converter assembly) on FC converter side and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.
After removal of the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
When reinstalling the service plug grip to the EV supply battery assembly, after lowering the EV supply battery assembly service plug grip 90°, securely slide it until a "click" sound is heard.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Forcing the SOC of the EV supply battery assembly to decrease by applying electrical loads such as turning on the air conditioning (HOT MAX, maximum airflow), or depressing the accelerator pedal with the shift state in park (P), the "FC Intermittent Operation" of the Data List is easily to enter OFF (power generation mode).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift lever in P, and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF. Then, wait for 1 minute or more.
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Result | Proceed to |
|---|---|
| Only P1D8396 is output | A |
| P1D8396 is output and DTCs other than the DTCs in the table below are output | B |
| P1D8396 is output and any DTCs in the table below are output | C |
| Malfunction Content | Malfunction Content | |
|---|---|---|
| Communication system malfunction | P1D8387 (EV) | Lost Communication with Hydrogen Pump Inverter Missing Message |
| System malfunction | P1C8449 (Hybrid (EV) Control System) | High Voltage Power Resource Circuit Short during Ready ON |
| P1A0F00 (Hybrid (EV) Control System) | DC/DC Converter "A" Overvoltage (Control Module Performance) | |
| P1A6F00 (Hybrid (EV) Control System) | DC/DC Converter "A" Overvoltage (Inverter Performance) | |
| P1A2F00 (Hybrid (EV) Control System) | DC/DC Converter "A" Overvoltage (Position Sensor Circuit Range/Performance) | |
| P1A7F00 (Hybrid (EV) Control System) | DC/DC Converter "A" Overvoltage (System Performance) | |
| P1A8400 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Overvoltage (Control Module Performance) | |
| P1A8E00 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Overvoltage (Inverter Performance) | |
| P1A8900 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Overvoltage (Position Sensor Circuit Range/Performance) | |
| P1A8F00 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Overvoltage (System Performance) | |
| P31B300 (Hybrid (EV) Control System) | Hybrid/EV Battery Voltage High | |
| P0A944B (Hybrid (EV) Control System) | DC/DC Converter "A" Over Temperature | |
| P1A9400 (Hybrid (EV) Control System) | DC/DC Converter "A" Overcurrent (Control Module Performance) | |
| P1AA400 (Hybrid (EV) Control System) | DC/DC Converter "A" Overcurrent (Inverter Performance) | |
| P1A9900 (Hybrid (EV) Control System) | DC/DC Converter "A" Overcurrent (Position Sensor Circuit Range/Performance) | |
| P1AA900 (Hybrid (EV) Control System) | DC/DC Converter "A" Overcurrent (System Performance) | |
| P0A949E (Hybrid (EV) Control System) | DC/DC Converter "A" Fail Signal Stuck On | |
| P1D824B (Hybrid (EV) Control System) | FC Air Compressor Inverter Over Temperature | |
| P1EF800 (Hybrid (EV) Control System) | FC Air Compressor Inverter Circuit Short (Control Module Performance) | |
| P1EFB00 (Hybrid (EV) Control System) | FC Air Compressor Inverter Circuit Short (Inverter Performance) | |
| P1EF900 (Hybrid (EV) Control System) | FC Air Compressor Inverter Circuit Short (Position Sensor Circuit Range/Performance) | |
| P1EFA00 (Hybrid (EV) Control System) | FC Air Compressor Inverter Circuit Short (System Performance) | |
| P1D829E (Hybrid (EV) Control System) | FC Air Compressor Inverter Fail Signal Stuck On | |
| P0A784B (Hybrid (EV) Control System) | Drive Motor "A" Inverter Over Temperature | |
| P1AB400 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Circuit Short (Control Module Performance) | |
| P1ABF00 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Circuit Short (Inverter Performance) | |
| P1AB900 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Circuit Short (Position Sensor Circuit Range/Performance) | |
| P1AC300 (Hybrid (EV) Control System) | Drive Motor "A" Inverter Circuit Short (System Performance) | |
| P0A789E (Hybrid (EV) Control System) | Drive Motor "A" Inverter Fail Signal Stuck On | |
DTC P1D8396 may be store due to problems that cause the DTCs shown above to output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.
Post-procedure1
Turn the ignition switch off.
A
B
C
Hybrid (EV) Control System:
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Pre-procedure1
None
Procedure1
Read the freeze frame data of DTC P1D8396.
| Tester Display |
|---|
| Hydrogen Pump Output Status |
| Result | Proceed to |
|---|---|
| The "Hydrogen Pump Output Status" of the freeze frame data shows Circuit Short. | A |
| Other than above. | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed to EV supply battery assembly and the FC converter power outlet cable (inverter with converter assembly) is not connected to the FC converter assembly.
After removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the hydrogen recirculation pump assembly connector from the hydrogen pump inverter assembly.
Procedure1
| *1 | Shield Ground |
| *a | Front view of wire harness connector
(to Hydrogen Recirculation Pump Assembly) |
Check the hydrogen pump assembly for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the hydrogen pump assembly temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z30)Location & Routingewd_type=routing;type=c;code=z30 Click Connector(z30)Engine Compartment>other>FC Converter Assembly , Hydrogen Recirculation Pump Assemblyewd_type=component;type=c;code=z30;pinno=3,2,1 |
||
| z30-3 (W) - z30-2 (V) | Ignition switch off | 622 to 762 mΩ |
| z30-3 (W) - z30-1 (U) | Ignition switch off | 622 to 762 mΩ |
| z30-2 (V) - z30-1 (U) | Ignition switch off | 622 to 762 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F))
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z30)Location & Routingewd_type=routing;type=c;code=z30 Click Connector(z30)Engine Compartment>other>FC Converter Assembly , Hydrogen Recirculation Pump Assemblyewd_type=component;type=c;code=z30;pinno=3,2,1 |
||
| z30-3 (W) - Body ground and shield ground | Ignition switch off | 50 MΩ or higher |
| z30-2 (V) - Body ground and shield ground | Ignition switch off | 50 MΩ or higher |
| z30-1 (U) - Body ground and shield ground | Ignition switch off | 50 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the hydrogen recirculation pump assembly connector to the hydrogen pump inverter assembly.
OK
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time
NG