Refer to the description for DTC P0A8111.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A8111
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A8100 | Hybrid/EV Battery Cooling Fan 1 Control Circuit High | Both of the following conditions are met:
·
The EV battery temperature is high and the EV battery cooling fan speed calculated based on the battery cooling blower assembly output frequency (FP0) is not within the target control speed range. ·
The EV battery temperature is high and the battery cooling blower assembly speed is excessively high when a speed below a certain level is requested. (1 trip detection logic) |
·
Battery cooling blower assembly ·
Battery ECU assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV Battery | A |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly output frequency (FP0) is not within the target control speed range. ·
The battery cooling blower assembly speed is excessively high when a speed below a certain level is requested. (2 trip detection logic) |
·
Battery cooling blower assembly ·
Battery ECU assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV Battery | A |
| DTC No. | Data List |
|---|---|
| P0A8100 | ·
Hybrid/EV Battery Cooling Fan 1 Drive Request ·
Hybrid/EV Battery Cooling Fan 1 Drive Status ·
Hybrid/EV Battery Cooling Fan 1 Frequency |
| P0A8115 |
The following items can be helpful when performing repairs:
Hybrid/EV Battery Temperature 1 to 6
BATT Voltage
"Hybrid/EV Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly speed.
If the battery cooling blower assembly speed is excessively high, this DTC is stored.
After repair has been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV Battery / Active Test / Control the Hybrid/EV Battery Cooling Fan.
Select fan mode 6 and operate the battery cooling blower assembly and wait for 60 seconds or more.
Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct or by operation sounds.
Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0A8111.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A8111
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A8100 or P0A8115 for Hybrid battery system is output | A |
| P0A8100 or P0A8115 is output and DTCs other than the DTCs in the table below are output | B |
| P0A8100 or P0A8115 is output and Hybrid battery system DTCs in the table below are output | C |
| P0A8100 or P0A8115 is output and Hybrid control system DTCs in the table below are output | D |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A8111
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A8111
| Proceed to |
|---|
| OK |
| NG |
OK
NG