DTC B1650/32 Occupant Classification System Malfunction |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| B1650/32 | When one of following conditions is met:
|
|

| 1.CHECK DTC (OCCUPANT CLASSIFICATION ECU) |
Turn the power switch ON (IG), and wait for at least 10 seconds.
Using the Techstream, check for DTCs of the occupant classification ECU (Click here).
|
| ||||
| NG | |
| 2.CHECK DTC (CENTER AIRBAG SENSOR ASSEMBLY) |
![]() |
Turn the power switch ON (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the power switch OFF.
Turn the power switch ON (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | |
| 3.CHECK CONNECTION OF CONNECTOR |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the center airbag sensor and the occupant classification ECU.
|
| ||||
| OK | |
| 4.CHECK FLOOR WIRE NO. 2 (OPEN) |
![]() |
Disconnect the connectors from the center airbag sensor and the occupant classification ECU.
Using a service wire, connect terminals O4-8 (FSR+) and O4-4 (FSR-) of connector C.
Measure the resistance of the wire harness side connector.
| Terminal Connection | Specified Condition |
| A19-16 (FSP+) - A19-24 (FSP-) | Below 1 Ω |
|
| ||||
| OK | |
| 5.CHECK FLOOR WIRE NO. 2 (SHORT) |
![]() |
Disconnect the service wire from connector C.
Measure the resistance of the wire harness side connector.
| Terminal Connection | Specified Condition |
| A19-16 (FSP+) - A19-24 (FSP-) | 1 MΩ or higher |
|
| ||||
| OK | |
| 6.CHECK FLOOR WIRE NO. 2 (TO B+) |
![]() |
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the power switch ON (IG).
Measure the voltage of the wire harness side connector.
| Terminal Connection | Specified Condition |
| A19-16 (FSP+) - Body ground | Below 1 V |
| A19-24 (FSP-) - Body ground | Below 1 V |
|
| ||||
| OK | |
| 7.CHECK FLOOR WIRE NO. 2 (TO GROUND) |
![]() |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance of the wire harness side connector.
| Terminal Connection | Specified Condition |
| A19-16 (FSP+) - Body ground | 1 MΩ or higher |
| A19-24 (FSP-) - Body ground | 1 MΩ or higher |
|
| ||||
| OK | |
| 8.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Replace the center airbag sensor (Click here).
Connect the connectors to the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the power switch ON (IG), and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the power switch OFF.
Turn the power switch ON (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| NG | |
| 9.REPLACE OCCUPANT CLASSIFICATION ECU |
Turn the power switch OFF.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Replace the occupant classification ECU (Click here).
| NEXT | |
| 10.PERFORM ZERO POINT CALIBRATION |
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Using the Techstream, perform the zero point calibration (Click here).
| NEXT | |
| 11.PERFORM SENSITIVITY CHECK |
Using the Techstream, perform the sensitivity check (Click here).
| NEXT | ||
| ||